Efficient wireless power delivery for biomedical implants

Power delivery for biomedical implants is a major consideration in their design for both measurement and stimulation. When performed by a wireless technique, transmission efficiency is critically important not only because of the costs associated with any losses but also because of the nature of those losses, for example, excessive heat can be uncomfortable for the individual involved. In this study, a method and means of wireless power transmission suitable for biomedical implants are both discussed and experimentally evaluated. The procedure initiated is comparable in size and simplicity to those methods already employed; however, some of Tesla's fundamental ideas have been incorporated in order to obtain a significant improvement in efficiency. This study contains a theoretical basis for the approach taken; however, the emphasis here is on practical experimental analysis.

[1]  H. Schulzrinne,et al.  Thought communication and control: a first step using radiotelegraphy , 2004 .

[2]  Gert Cauwenberghs,et al.  Power harvesting and telemetry in CMOS for implanted devices , 2004, IEEE Transactions on Circuits and Systems I: Regular Papers.

[3]  M. Soljačić,et al.  Efficient wireless non-radiative mid-range energy transfer , 2006, physics/0611063.

[4]  Nikolaos G. Bourbakis,et al.  A Survey on Wearable Sensor-Based Systems for Health Monitoring and Prognosis , 2010, IEEE Transactions on Systems, Man, and Cybernetics, Part C (Applications and Reviews).

[5]  Jonathan S. Shipley Incorporating Wireless Power Transfer in an LED Lighting Application , 2006 .

[6]  Kathleen Ann O'brien,et al.  Magnetic field generation in an inductively coupled radio-frequency power transmission system , 2006 .

[7]  Kevin Warwick,et al.  The application of implant technology for cybernetic systems. , 2003, Archives of neurology.

[8]  O. Breinbjerg,et al.  Resonantly coupled antennas for passive sensors , 2008, 2008 IEEE Sensors.

[9]  Reid R. Harrison,et al.  Micropower circuits for bidirectional wireless telemetry in neural recording applications , 2005, IEEE Transactions on Biomedical Engineering.

[10]  S. Barker,et al.  Piezoelectric-powered wireless sensor system with regenerative transmit mode , 2011, IET Wirel. Sens. Syst..

[11]  Thomas Commerford Martin The inventions, researches and writings of Nikola Tesla with special reference to his work in polyphase currents and high potential lighting , 1894 .

[12]  Shahriar Mirabbasi,et al.  Design and Optimization of Resonance-Based Efficient Wireless Power Delivery Systems for Biomedical Implants , 2011, IEEE Transactions on Biomedical Circuits and Systems.

[13]  J. Corum,et al.  RF coils, helical resonators and voltage magnification by coherent spatial modes , 2001, 5th International Conference on Telecommunications in Modern Satellite, Cable and Broadcasting Service. TELSIKS 2001. Proceedings of Papers (Cat. No.01EX517).

[14]  John Henry Poynting I. On the connexion between electric current and the electric and magnetic inductions in the surrounding field , 1885, Philosophical Transactions of the Royal Society of London.

[15]  S.C. Goldstein,et al.  Magnetic Resonant Coupling As a Potential Means for Wireless Power Transfer to Multiple Small Receivers , 2009, IEEE Transactions on Power Electronics.

[16]  E Romero,et al.  Energy scavenging sources for biomedical sensors , 2009, Physiological measurement.

[17]  S. K. Guha,et al.  Transmission of time varying magnetic field through body tissue , 1975 .

[18]  Matthew S. Reynolds,et al.  Surface based wireless power transmission and bidirectional communication for autonomous robot swarms , 2008, 2008 IEEE International Conference on Robotics and Automation.

[19]  Zhi Yang,et al.  An efficient wireless power link for high voltage retinal implant , 2008, 2008 IEEE Biomedical Circuits and Systems Conference.

[20]  J. H. Poynting XV. On the transfer of energy in the electromagnetic field , 1884, Philosophical Transactions of the Royal Society of London.

[21]  C.M. Zierhofer,et al.  Geometric approach for coupling enhancement of magnetically coupled coils , 1996, IEEE Transactions on Biomedical Engineering.

[22]  A. Benabid,et al.  Electrical stimulation of the subthalamic nucleus in advanced Parkinson's disease. , 1998, The New England journal of medicine.

[23]  M. Ghovanloo,et al.  A Wireless Implantable Multichannel Microstimulating System-on-a-Chip With Modular Architecture , 2007, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[24]  William G. Scanlon,et al.  Improving the ultra-low-power performance of IEEE 802.15.6 by adaptive synchronisation , 2011, IET Wirel. Sens. Syst..

[25]  Erwin S. Hochmair,et al.  System Optimization for Improved Accuracy in Transcutaneous Signal and Power Transmission , 1984, IEEE Transactions on Biomedical Engineering.

[26]  Rahul Sarpeshkar,et al.  Feedback Analysis and Design of RF Power Links for Low-Power Bionic Systems , 2007, IEEE Transactions on Biomedical Circuits and Systems.

[27]  H. Haus,et al.  Coupled-mode theory , 1991, Proc. IEEE.

[28]  L. Hannakam Berechnung der Gegeninduktivität achsenparalleler Zylinderspulen , 1967 .

[29]  J. Gao Inductive power transmission for untethered micro-robots , 2005, 31st Annual Conference of IEEE Industrial Electronics Society, 2005. IECON 2005..