Ultra-wideband electromagnetic pulses: lack of effects on heart rate and blood pressure during two-minute exposures of rats.

Exposure to fast-rise-time ultra-wideband (UWB) electromagnetic pulses has been postulated to result in effects on biological tissue (including the cardiovascular system). In the current study, 10 anesthetized Sprague-Dawley rats were exposed to pulses produced by a Sandia UWB pulse generator (average values of exposures over three different pulse repetition rates: rise time, 174-218 ps; peak E field, 87-104 kV/m; pulse duration, 0.97-0.99 ns). Exposures to 50, 500 and 1000 pulses/s resulted in no significant changes in heart rate or mean arterial blood pressure measured every 30 s during 2 min of exposure and for 2 min after the exposure. The results suggest that acute UWB whole-body exposure under these conditions does not have an immediate detrimental effect on these cardiovascular system variables in anesthetized rats.

[1]  F. J. Agee,et al.  Powerful ultrawideband rf emitters: status and challenges , 1995, Optics & Photonics.

[2]  T J Walters,et al.  Lack of behavioral effects in non-human primates after exposure to ultrawideband electromagnetic radiation in the microwave frequency range. , 1995, Radiation research.

[3]  Tests of biological integrity in dogs exposed to an electromagnetic pulse environment. , 1979, Health physics.

[4]  Merritt Jh,et al.  Considerations for human exposure standards for fast-rise-time high-peak-power electromagnetic pulses. , 1995 .

[5]  Jian-Zhong Bao,et al.  Picosecond domain electromagnetic pulse measurements in an exposure facility: An error compensation routine using deconvolution techniques , 1997 .

[6]  J. Jauchem,et al.  Cardiorespiratory changes during microwave-induced lethal heat stress and beta-adrenergic blockade. , 1994, Journal of applied physiology.

[7]  James R. Jauchem,et al.  Exposure to extremely-low-frequency electromagnetic fields and radiofrequency radiation: cardiovascular effects in humans , 1997, International archives of occupational and environmental health.

[8]  P. A. Mason,et al.  No detectable bioeffects following acute exposure to high peak power ultra-wide band electromagnetic radiation in rats. , 1995, Aviation, space, and environmental medicine.

[9]  J R Jauchem,et al.  High-peak-power microwave pulses: effects on heart rate and blood pressure in unanesthetized rats. , 1995, Aviation, space, and environmental medicine.

[10]  Adair Rk Ultrashort microwave signals: a didactic discussion. , 1995 .

[11]  O. Gandhi,et al.  Currents induced in an anatomically based model of a human for exposure to vertically polarized electromagnetic pulses , 1991 .