Extension of the characteristic equation to absorption chillers with adiabatic absorbers

Various researchers have developed models of conventional H2O–LiBr absorption machines with the aim of predicting their performance. In this paper, the methodology of characteristic equations developed by Hellmann et al. (1998) is applied. This model is able to represent the capacity of single effect absorption chillers and heat pumps by means of simple algebraic equations. An extended characteristic equation based on a characteristic temperature difference has been obtained, considering the facility features. As a result, it is concluded that for adiabatic absorbers a subcooling temperature must be specified. The effect of evaporator overflow has been characterized. Its influence on cooling capacity has been included in the extended characteristic equation. Taking into account the particular design and operation features, a good agreement between experimental performance data and those obtained through the extended characteristic equation has been achieved at off-design operation. This allows its use for simulation and control purposes.

[1]  Georgios A. Florides,et al.  Design and construction of a LiBr–water absorption machine , 2003 .

[2]  Frank P. Incropera,et al.  Fundamentals of Heat and Mass Transfer , 1981 .

[3]  William M. Worek,et al.  Adiabatic water absorption properties of an aqueous absorbent at very low pressures in a spray absorber , 2006 .

[4]  M. Izquierdo,et al.  Experimental study on the adiabatic absorption of water vapor into LiBr–H2O solutions , 2005 .

[5]  Coupled heat and mass transfer during nonisothermal absorption by falling droplet with internal circulation , 2007 .

[6]  M. Izquierdo,et al.  Spray absorbers in absorption systems using lithium nitrate–ammonia solution , 2005 .

[7]  P. Riesch,et al.  Hydroxide absorption heat pumps with spray absorber , 1996 .

[8]  Khalid A. Joudi,et al.  Simulation of a simple absorption refrigeration system , 2001 .

[9]  C. A. Infante Ferreira,et al.  Analytic modelling of steady state single-effect absorption cycles , 2008 .

[10]  Experimental performances of a LiBr-water absorption facility equipped with adiabatic absorber , 2011 .

[11]  R. Ventas,et al.  On the recirculation of ammonia-lithium nitrate in adiabatic absorbers for chillers , 2010 .

[12]  M. Izquierdo,et al.  Heat and mass transfer during absorption of ammonia vapour by LiNO3–NH3 solution droplets , 2004 .

[13]  William A. Ryan Water absorption in an adiabatic spray of aqueous lithium bromide solution , 1994 .

[14]  Guangming Chen,et al.  Thermodynamic performance analysis of gas-fired air-cooled adiabatic absorption refrigeration systems , 2007 .