1-Butyl-3-Methylimidazolium Tetrafluoroborate Film as a Highly Selective Sensing Material for Non-Invasive Detection of Acetone Using a Quartz Crystal Microbalance

Breath acetone serves as a biomarker for diabetes. This article reports 1-butyl-3-methylimidazolium tetrafluoroborate ([bmim][BF4]), a type of room temperature ionic liquid (RTIL), as a selective sensing material for acetone. The RTIL sensing layer was coated on a quartz crystal microbalance (QCM) for detection. The sensing mechanism is based on a decrease in viscosity and density of the [bmim][BF4] film due to the solubilization of acetone leading to a positive frequency shift in the QCM. Acetone was detected with a linear range from 7.05 to 750 ppmv. Sensitivity and limit of detection were found to be 3.49 Hz/ppmv and 5.0 ppmv, respectively. The [bmim][BF4]-modified QCM sensor demonstrated anti-interference ability to commonly found volatile organic compounds in breath, e.g., isoprene, 1,2-pentadiene, d-limonene, and dl-limonene. This technology is useful for applications in non-invasive early diabetic diagnosis.

[1]  R. Maeda,et al.  Detection of Volatile Organic Compounds by Weight-Detectable Sensors coated with Metal-Organic Frameworks , 2014, Scientific Reports.

[2]  G. Wong,et al.  [Exhaled nitric oxide in asthma]. , 2005, Zhonghua er ke za zhi = Chinese journal of pediatrics.

[3]  John Mortensen,et al.  Polymer coated quartz crystal microbalance sensors for detection of volatile organic compounds in gas mixtures. , 2007, Analytica chimica acta.

[4]  Haihui Wang,et al.  Competitive adsorption of water vapor with VOCs dichloroethane, ethyl acetate and benzene on MIL-101(Cr) in humid atmosphere , 2015 .

[5]  Raed A Dweik,et al.  Exhaled nitric oxide in asthma. From diagnosis, to monitoring, to screening: are we there yet? , 2008, Chest.

[6]  Richard G. Brereton,et al.  Analysis of Volatile Organic Compounds in Human Saliva by a Static Sorptive Extraction Method and Gas Chromatography-Mass Spectrometry , 2010, Journal of Chemical Ecology.

[7]  K L Ngai,et al.  Glass transition dynamics of room-temperature ionic liquid 1-methyl-3-trimethylsilylmethylimidazolium tetrafluoroborate. , 2011, The journal of physical chemistry. B.

[8]  S. Yao,et al.  A Comparative Study on the Viscoelasticity and Morphology of Polyaniline Films Galvanostatically Grown on Bare and 4-Aminothiophenol-Modified Gold Electrodes Using an Electrochemical Quartz Crystal Impedance System and SEM , 2001, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.

[9]  M. Shepherd,et al.  A Study on Breath Acetone in Diabetic Patients Using a Cavity Ringdown Breath Analyzer: Exploring Correlations of Breath Acetone With Blood Glucose and Glycohemoglobin A1C , 2010, IEEE Sensors Journal.

[10]  N. Likhanova,et al.  Ionic liquids screening for desulfurization of natural gasoline by liquid–liquid extraction , 2010, Molecular Diversity.

[11]  Zeynep Altintas,et al.  Sensitive detection of Campylobacter jejuni using nanoparticles enhanced QCM sensor. , 2016, Biosensors & bioelectronics.

[12]  M. Grätzel,et al.  Hydrophobic, Highly Conductive Ambient-Temperature Molten Salts. , 1996, Inorganic chemistry.

[13]  X. Zhang,et al.  Determination of acetone in human breath by gas chromatography-mass spectrometry and solid-phase microextraction with on-fiber derivatization. , 2004, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[14]  Raffaele Velotta,et al.  Detection of parathion and patulin by quartz-crystal microbalance functionalized by the photonics immobilization technique. , 2015, Biosensors & bioelectronics.

[15]  Massimo Corradi,et al.  Nitrate in exhaled breath condensate of patients with different airway diseases. , 2003, Nitric oxide : biology and chemistry.

[16]  Ionic liquids used as QCM coating materials for the detection of alcohols , 2008 .

[17]  Properties of 1,3-dialkylimidazolium chloride-aluminum chloride ionic liquids. 2. Phase transitions, densities, electrical conductivities, and viscosities , 1984 .

[18]  Tadeusz Pustelny,et al.  A Study of a QCM Sensor Based on TiO2 Nanostructures for the Detection of NO2 and Explosives Vapours in Air , 2015, Sensors.

[19]  Xiangqun Zeng,et al.  Differential solute gas response in ionic-liquid-based QCM arrays: elucidating design factors responsible for discriminative explosive gas sensing. , 2011, Analytical chemistry.

[20]  Sandeep Kumar Vashist,et al.  Recent Advances in Quartz Crystal Microbalance-Based Sensors , 2011, J. Sensors.

[21]  T. Welton Room-Temperature Ionic Liquids. Solvents for Synthesis and Catalysis. , 1999, Chemical reviews.

[22]  Akhtar Hayat,et al.  Design of a novel filter paper based construct for rapid analysis of acetone , 2018, PloS one.

[23]  Christopher Walton,et al.  Breath acetone concentration decreases with blood glucose concentration in type I diabetes mellitus patients during hypoglycaemic clamps , 2009, Journal of breath research.

[24]  T R Fraser,et al.  Breath acetone and blood sugar measurements in diabetes. , 1969, Clinical science.

[25]  R. Vilar,et al.  Chromium electrodeposition from [BMIm][BF4] ionic liquid , 2011 .

[26]  M. Phillips,et al.  Volatile Markers of Breast Cancer in the Breath , 2003, The breast journal.

[27]  S. Yao,et al.  An electrochemical quartz crystal impedance study on cystine precipitation onto an Au electrode surface during cysteine oxidation in aqueous solution , 2000 .

[28]  K. Seddon,et al.  Influence of chloride, water, and organic solvents on the physical properties of ionic liquids , 2000 .

[29]  M. Phillips,et al.  Variation in volatile organic compounds in the breath of normal humans. , 1999, Journal of chromatography. B, Biomedical sciences and applications.

[30]  M. Phillips Method for the collection and assay of volatile organic compounds in breath. , 1997, Analytical biochemistry.

[31]  F. Emmenegger,et al.  Co-solvents for chloroaluminate electrolytes , 1992 .

[32]  J. Gordon,et al.  The oscillation frequency of a quartz resonator in contact with liquid , 1985 .

[33]  Stephen J. Martin,et al.  Characterization of a quartz crystal microbalance with simultaneous mass and liquid loading , 1991 .

[34]  T. Stacewicz,et al.  Ultrasensitive laser spectroscopy for breath analysis , 2012 .

[35]  C. Kaminski,et al.  Optical detection of the anesthetic agent propofol in the gas phase. , 2011, Analytical chemistry.

[36]  Bernd Becker,et al.  A survey of the 2006–2009 quartz crystal microbalance biosensor literature , 2011, Journal of molecular recognition : JMR.

[37]  Q. Zhang,et al.  Diagnosis of diabetes by image detection of breath using gas-sensitive LAPS. , 2000, Biosensors & bioelectronics.

[38]  C. Hussey,et al.  Densities, Viscosities, and Conductivities of Mixtures of Benzene with the Lewis Acidic Aluminum Chloride + 1-Methyl-3-ethylimidazolium Chloride Molten Salt , 1996 .

[39]  Leiliane Coelho A Amorim,et al.  Breath air analysis and its use as a biomarker in biological monitoring of occupational and environmental exposure to chemical agents. , 2007, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[40]  M. Phillips,et al.  Increased pentane and carbon disulfide in the breath of patients with schizophrenia. , 1993, Journal of clinical pathology.

[41]  P. Bartlett,et al.  An instrument for simultaneous EQCM impedance and SECM measurements. , 2000, Analytical chemistry.

[42]  C. Liang,et al.  Ionic liquids: a new class of sensing materials for detection of organic vapors based on the use of a quartz crystal microbalance. , 2002, Analytical chemistry.

[43]  Norman Ratcliffe,et al.  Volatile organic compounds as diagnostic biomarkers in gastrointestinal and liver diseases. , 2009, Journal of gastrointestinal and liver diseases : JGLD.

[44]  Jia Zhou,et al.  A highly sensitive QCM sensor coated with Ag+-ZSM-5 film for medical diagnosis , 2004 .

[45]  Tom Welton,et al.  Room-temperature ionic liquids: solvents for synthesis and catalysis. 2. , 1999, Chemical reviews.