Unified multiple‐feature color display for MR images

A display method is proposed in which the spin‐lattice relaxation time T1, the spinspin relaxation time T2, and the proton density ρ of each pixel in a MR image are simultaneously expressed in color features in a unified way that allows international standardization. MR images were made from a phantom, a healthy volunteer, and patients in such a way that T1 and T2 and proton density images could be derived. T1 and T2 data were compared with accurate relaxation time measurements of the phantom content. Color images were computed from the acquired T1 and T2 images using matrix multiplication on a pixel base. In this way the color combination in each pixel represents the properties of that particular pixel by a unique mixing of the elementary colors red, green, and blue. Color resolution could be modified using different choices of the reference triangle in which the color combinations were defined. This method of representation offers a means for displaying multiple features as T1, and T2 in one directly interpretable image, independent of instrumental settings. © 1989 Academic Press, Inc.

[1]  I. Pykett,et al.  Instant images of the human heart using a new, whole-body MR imaging system. , 1987, AJR. American journal of roentgenology.

[2]  S. Meindl,et al.  Erste klinische Ergebnisse der Gewebecharakterisierung durch T1, T2 und Protonendichte bei der Kernspintomographie1, 2 , 1987 .

[3]  J. Hutchison,et al.  NUCLEAR MAGNETIC RESONANCE TOMOGRAPHIC IMAGING IN LIVER DISEASE , 1981, The Lancet.

[4]  T Tolxdorff,et al.  Identification and characterization of tissues by T2‐selective whole‐body proton NMR imaging , 1985, Magnetic resonance in medicine.

[5]  R. L. Butterfield,et al.  Multispectral analysis of magnetic resonance images. , 1985, Radiology.

[6]  D N Firmin,et al.  Colour display of quantitative blood flow and cardiac anatomy in a single magnetic resonance cine loop. , 1987, The British journal of radiology.

[7]  P. Dijk Direct cardiac NMR imaging of heart wall and blood flow velocity. , 1984 .

[8]  J Hoenninger,et al.  Nuclear magnetic resonance whole-body imager operating at 3.5 KGauss. , 1982, Radiology.

[9]  J. Hunter,et al.  Parametric imaging using digital subtraction angiography. , 1986, The British journal of radiology.

[10]  R L Kamman,et al.  Interpretation of Magnetic Resonance Images Making Use of In Vitro Examinations of Spinal Tissue , 1987, Spine.

[11]  M W Vannier,et al.  Multispectral analysis of MR images of the breast. , 1987, Radiology.

[12]  K. Gersonde,et al.  Analysis of multiple T2 proton relaxation processes in human head and imaging on the basis of selective and assigned T2 values , 1984, Magnetic resonance in medicine.

[13]  C. N. de Graaf,et al.  Derivation of quantitative information in NMR imaging: a phantom study , 1984 .

[14]  J F Cornhill,et al.  Hybrid color MR imaging display. , 1987, AJR. American journal of roentgenology.

[15]  D. Levin,et al.  Oscillating Intensity Display of Soft Tissue Lesions in MRI , 1987, IEEE Transactions on Medical Imaging.