Small volume PCR in PDMS biochips with integrated fluid control and vapour barrier

Abstract In this paper we demonstrate a new method for microfabricating PDMS devices that controls vapour diffusion, thereby reducing water loss at elevated temperatures and greatly increasing the reliability of the PCR. In the past, the vapour and liquid diffusion properties of the PDMS material in microfluidic devices have impaired performance. We show that this water loss is primarily due to vapour diffusion from the PDMS biochip and by implanting a polyethylene vapour barrier layer in the PDMS, the overall fluid loss was almost eliminated (reduced by a factor of 3). We have also developed a procedure to ensure irreversible bonding between the PDMS and the implant. With this improved microfabrication method we demonstrate the feasibility and advantages of performing small volume PCR genetic amplification (i.e. with less than 2 μl of PCR sample) within a PDMS–glass hybrid biochip. Diaphragm pumps and pinch-off valves were integrated in the system and these enabled fluid retention during the amplification stage and will facilitate higher levels of on-chip automation.

[1]  S. Quake,et al.  Monolithic microfabricated valves and pumps by multilayer soft lithography. , 2000, Science.

[2]  H. John Crabtree,et al.  Microchip injection and separation anomalies due to pressure effects. , 2001, Analytical chemistry.

[3]  L J Kricka,et al.  Microchip PCR , 2003, Analytical and bioanalytical chemistry.

[4]  J. M. Henis,et al.  Composite Hollow Fiber Membranes for Gas Separation: The Resistance Model Approach , 1981 .

[5]  Carlos H. Mastrangelo,et al.  Cast epoxy-based microfluidic systems and their application in biotechnology , 2004 .

[6]  Frontal analysis on a microchip. , 2002, The Analyst.

[7]  H. John Crabtree,et al.  Microfabricated device for DNA and RNA amplification by continuous-flow polymerase chain reaction and reverse transcription-polymerase chain reaction with cycle number selection. , 2003, Analytical chemistry.

[8]  Xiaomei Yu,et al.  3-D microarrays biochip for DNA amplification in polydimethylsiloxane (PDMS) elastomer , 2003 .

[9]  J. Harris,et al.  Single-molecule fluorescence trajectories for investigating molecular transport in thin silica sol-gel films. , 2003, Analytical chemistry.

[10]  T. Merkel,et al.  Gas sorption, diffusion, and permeation in poly(dimethylsiloxane) , 2000 .

[11]  Ivan Erill,et al.  Biochemical analysis and optimization of inhibition and adsorption phenomena in glass–silicon PCR-chips , 2003 .

[12]  J. M. Watson,et al.  The behaviour of water in poly(dimethylsiloxane) , 1996 .

[13]  T Fujii,et al.  Integration of gene amplification and capillary gel electrophoresis on a polydimethylsiloxane‐glass hybrid microchip , 2001, Electrophoresis.

[14]  D. Erickson,et al.  Integrated microfluidic devices , 2004 .

[15]  Y. L. Cheng,et al.  Preparation of PDMS−PMAA Interpenetrating Polymer Network Membranes Using the Monomer Immersion Method , 2000 .

[16]  J P Landers,et al.  Polymerase chain reaction in polymeric microchips: DNA amplification in less than 240 seconds. , 2001, Analytical biochemistry.

[17]  G. Whitesides,et al.  Poly(dimethylsiloxane) as a material for fabricating microfluidic devices. , 2002, Accounts of chemical research.

[18]  Fubing Peng,et al.  Analysis of the gas transport performance through PDMS/PS composite membranes using the resistances-in-series model , 2003 .

[19]  D. Clicq,et al.  Enhancement of DNA micro-array analysis using a shear-driven micro-channel flow system. , 2003, Journal of chromatography. A.

[20]  David T. Burke,et al.  Microfabricated devices for genetic diagnostics , 1998, Proc. IEEE.

[21]  R. Mathies,et al.  Monolithic integrated microfluidic DNA amplification and capillary electrophoresis analysis system , 2000 .

[22]  Stephen Quake,et al.  A nanoliter rotary device for polymerase chain reaction , 2002, Electrophoresis.

[23]  M. Chaudhury,et al.  Hydrophobicity loss and recovery of silicone HV insulation , 1999, IEEE Transactions on Dielectrics and Electrical Insulation.

[24]  R. C. Weast Handbook of chemistry and physics , 1973 .

[25]  Richard J. Colton,et al.  Hybrid macro–micro fluidics system for a chip-based biosensor , 2002 .

[26]  G. Whitesides,et al.  Solvent compatibility of poly(dimethylsiloxane)-based microfluidic devices. , 2003, Analytical chemistry.

[27]  Peter Enoksson,et al.  A Valve-Less Diffuser Micropump for Microfluidic Analytical Systems , 2001 .

[28]  George M. Whitesides,et al.  Microfluidics Section: Design and Fabrication of Integrated Passive Valves and Pumps for Flexible Polymer 3-Dimensional Microfluidic Systems , 2002 .

[29]  M. Kontominas,et al.  Effect of ionizing radiation on the physicochemical and mechanical properties of commercial monolayer flexible plastics packaging materials , 2002, Food additives and contaminants.

[30]  H. Hillborg,et al.  Hydrophobicity changes in silicone rubbers , 1999, IEEE Transactions on Dielectrics and Electrical Insulation.

[31]  C. A. Smolders,et al.  Vapour sorption and permeation properties of poly(dimethylsiloxane) films , 1991 .

[32]  M. Ladisch,et al.  Poly(dimethylsiloxane) (PDMS) and Silicon Hybrid Biochip for Bacterial Culture , 2003 .

[33]  G. Whitesides,et al.  Components for integrated poly(dimethylsiloxane) microfluidic systems , 2002, Electrophoresis.

[34]  George M Whitesides,et al.  Replication of vertical features smaller than 2 nm by soft lithography. , 2003, Journal of the American Chemical Society.

[35]  Jianing Yang,et al.  High sensitivity PCR assay in plastic micro reactors. , 2002, Lab on a chip.

[36]  Joseph Wang,et al.  Microchip devices for detecting terrorist weapons , 2003 .

[37]  Stephen R Quake,et al.  Solving the "world-to-chip" interface problem with a microfluidic matrix. , 2003, Analytical chemistry.

[38]  J. M. Lee,et al.  Vapor permeations of a series of VOCs/N2 mixtures through PDMS membrane , 2002 .

[39]  Hye Jung Cho,et al.  Precise temperature control and rapid thermal cycling in a micromachined DNA polymerase chain reaction chip , 2002 .

[40]  P. Bergveld,et al.  Polydimethylsiloxane, a photocurable rubberelastic polymer used as spring material in micromechanical sensors , 1997 .

[41]  P. Pfromm,et al.  Effect of copolymer composition on the solubility and diffusivity of water and methanol in a series of polyether amides , 1997 .

[42]  Dong-Chul Han,et al.  PDMS-based micro PCR chip with Parylene coating , 2003 .

[43]  Sabu Thomas,et al.  Transport phenomena through polymeric systems , 2001 .

[44]  Y. Murakami,et al.  Development of a microchamber array for picoliter PCR. , 2001, Analytical chemistry.

[45]  William H. Grover,et al.  Monolithic membrane valves and diaphragm pumps for practical large-scale integration into glass microfluidic devices , 2003 .

[46]  R. C. Weast CRC Handbook of Chemistry and Physics , 1973 .

[47]  W. Stremmel,et al.  Expression of hepcidin in hereditary hemochromatosis: evidence for a regulation in response to the serum transferrin saturation and to non-transferrin-bound iron. , 2003, Blood.

[48]  P. Veltink,et al.  The mechanical properties of the rubber elastic polymer polydimethylsiloxane for sensor applications , 1997 .