Wireless Technologies for Implantable Devices

Wireless technologies are incorporated in implantable devices since at least the 1950s. With remote data collection and control of implantable devices, these wireless technologies help researchers and clinicians to better understand diseases and to improve medical treatments. Today, wireless technologies are still more commonly used for research, with limited applications in a number of clinical implantable devices. Recent development and standardization of wireless technologies present a good opportunity for their wider use in other types of implantable devices, which will significantly improve the outcomes of many diseases or injuries. This review briefly describes some common wireless technologies and modern advancements, as well as their strengths and suitability for use in implantable medical devices. The applications of these wireless technologies in treatments of orthopedic and cardiovascular injuries and disorders are described. This review then concludes with a discussion on the technical challenges and potential solutions of implementing wireless technologies in implantable devices.

[1]  B. Nelson A Smart Implantable Bone Fixation Plate Providing Actuation and Load Monitoring for Orthopedic Fracture Healing , 2019 .

[3]  Bernhard Weisse,et al.  Magnetoelastic Strain Sensor for Optimized Assessment of Bone Fracture Fixation , 2009, IEEE Sensors Journal.

[4]  A. N. Bashkatov,et al.  Optical properties of human skin, subcutaneous and mucous tissues in the wavelength range from 400 to 2000 nm , 2005 .

[5]  G. ter Haar Ultrasound bioeffects and safety. , 2010, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[6]  K. Wise,et al.  A wireless microsensor for monitoring flow and pressure in a blood vessel utilizing a dual-inductor antenna stent and two pressure sensors , 2004, 17th IEEE International Conference on Micro Electro Mechanical Systems. Maastricht MEMS 2004 Technical Digest.

[7]  Amin Arbabian,et al.  A mm-Sized Wireless Implantable Device for Electrical Stimulation of Peripheral Nerves , 2018, IEEE Transactions on Biomedical Circuits and Systems.

[8]  J. Williamson,et al.  2017 ACC/AHA/AAPA/ABC/ACPM/AGS/APhA/ASH/ASPC/NMA/PCNA Guideline for the Prevention, Detection, Evaluation, and Management of High Blood Pressure in Adults: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines. , 2018, Circulation.

[9]  C. Bulpitt,et al.  Incident dementia and blood pressure lowering in the Hypertension in the Very Elderly Trial cognitive function assessment (HYVET-COG): a double-blind, placebo controlled trial , 2008, The Lancet Neurology.

[10]  T. Young,et al.  Sleep apnea and cardiovascular disease: an American Heart Association/American College of Cardiology Foundation Scientific Statement from the American Heart Association Council for High Blood Pressure Research Professional Education Committee, Council on Clinical Cardiology, Stroke Council, and Coun , 2008, Journal of the American College of Cardiology.

[11]  Bryan A. Chin,et al.  Design and characterization of a magnetoelastic sensor for the detection of biological agents , 2010 .

[12]  Axel Montagne,et al.  Cerebral blood flow regulation and neurovascular dysfunction in Alzheimer disease , 2017, Nature Reviews Neuroscience.

[13]  Nader Najafi,et al.  Initial Animal Studies of a Wireless, Batteryless, MEMS Implant for Cardiovascular Applications , 2004, Biomedical microdevices.

[14]  Robert K. Shepherd Neurobionics: The Biomedical Engineering of Neural Prostheses: The Biomedical Engineering of Neural Prostheses , 2016 .

[15]  M. Stordeur,et al.  New micro thermoelectric devices based on bismuth telluride-type thin solid films , 1999, Eighteenth International Conference on Thermoelectrics. Proceedings, ICT'99 (Cat. No.99TH8407).

[16]  Craig A. Grimes,et al.  Wireless Magnetoelastic Resonance Sensors: A Critical Review , 2002 .

[17]  A. Zurbuchen,et al.  Energy Harvesting by Subcutaneous Solar Cells: A Long-Term Study on Achievable Energy Output , 2017, Annals of Biomedical Engineering.

[18]  Kevin Fu,et al.  Security and Privacy for Implantable Medical Devices , 2008, IEEE Pervasive Comput..

[19]  Ian Papautsky,et al.  Implantable MEMS compressive stress sensors: Design, fabrication and calibration with application to the disc annulus. , 2010, Journal of biomechanics.

[20]  M. Pearcy,et al.  Clinical implications of stiffness and strength changes in fracture healing. , 1997, The Journal of bone and joint surgery. British volume.

[21]  O Paiva,et al.  Concept, design and fabrication of smart orthopedic implants. , 2000, Medical engineering & physics.

[22]  K Kramer,et al.  A new method for measurement of blood pressure, heart rate, and activity in the mouse by radiotelemetry. , 2000, Journal of applied physiology.

[23]  D. Lichtenstein,et al.  Ultrasound diagnosis of alveolar consolidation in the critically ill , 2004, Intensive Care Medicine.

[24]  A. Crawford,et al.  In Vivo Dynamic Compressive Stresses in the Disc Annulus: A Pilot Study of Bilateral Differences Due to Hemiepiphyseal Implant in a Quadruped Model , 2012, Spine.

[25]  D. Franklin,et al.  Telemetry of blood pressure in free-ranging animals via an intravascular gauge. , 1966, Journal of applied physiology.

[26]  Christopher Paul Cole,et al.  eDisc: The First Artificial Spinal Disc With Integral Force-Sensing Microelectronics , 2007 .

[27]  Antonius Rohlmann,et al.  High-Tech Hip Implant for Wireless Temperature Measurements In Vivo , 2012, PloS one.

[28]  C A Grimes,et al.  A remote query magnetostrictive viscosity sensor. , 2000, Sensors and actuators. A, Physical.

[29]  A. Nachemson,et al.  Lumbar intradiscal pressure. Experimental studies on post-mortem material. , 1960, Acta orthopaedica Scandinavica. Supplementum.

[30]  J. L. Cunningham,et al.  Monitoring the Mechanical Properties of Healing Bone , 2009, Clinical orthopaedics and related research.

[31]  Voon Chin Phua,et al.  Wireless lan medium access control (mac) and physical layer (phy) specifications , 1999 .

[32]  G Bergmann,et al.  Four-channel telemetry system for in vivo measurement of hip joint forces. , 1991, Journal of biomedical engineering.

[33]  R. Calton,et al.  Longest lasting VVI pacemaker on the Indian subcontinent: Over 28.1 years of pacing without requiring pulse generator replacement , 2018, IHJ Cardiovascular Case Reports (CVCR).

[34]  Joseph A Potkay,et al.  Long term, implantable blood pressure monitoring systems , 2008, Biomedical microdevices.

[35]  Bradley D Nelson,et al.  Clinical potential of implantable wireless sensors for orthopedic treatments , 2018, Expert review of medical devices.

[36]  A H Burstein,et al.  Telemetering in vivo loads from nail plate implants. , 1982, Journal of biomechanics.

[37]  C. Gabriel Compilation of the Dielectric Properties of Body Tissues at RF and Microwave Frequencies. , 1996 .

[38]  A Rohlmann,et al.  Multichannel strain gauge telemetry for orthopaedic implants. , 1988, Journal of biomechanics.

[39]  S. Farritor,et al.  The use of piezoelectric ceramics for electric power generation within orthopedic implants , 2005, IEEE/ASME Transactions on Mechatronics.

[40]  W.J. Chappell,et al.  Evaluation of Cardiovascular Stents as Antennas for Implantable Wireless Applications , 2009, IEEE Transactions on Microwave Theory and Techniques.

[41]  E Schneider,et al.  Loads acting in an intramedullary nail during fracture healing in the human femur. , 2001, Journal of biomechanics.

[42]  Keat Ghee Ong,et al.  Magneto-harmonic pressure sensor for biomedical applications , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[43]  Maysam Ghovanloo,et al.  Optimal Design of Wireless Power Transmission Links for Millimeter-Sized Biomedical Implants , 2016, IEEE Transactions on Biomedical Circuits and Systems.

[44]  K. Najafi,et al.  An Implantable Microsystem for Tonometric Blood Pressure Measurement , 2001 .

[45]  S. Ozeri,et al.  Ultrasonic transcutaneous energy transfer for powering implanted devices. , 2010, Ultrasonics.

[46]  A. Tosteson,et al.  Incidence and Economic Burden of Osteoporosis‐Related Fractures in the United States, 2005–2025 , 2007, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[47]  B. Towe,et al.  Miniature ultrasonically powered wireless nerve cuff stimulator , 2011, 2011 5th International IEEE/EMBS Conference on Neural Engineering.

[48]  F. Umbrecht,et al.  Novel Ultrasound Read-Out for a Wireless Implantable Passive Strain Sensor (WIPSS) , 2007, TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference.

[49]  M. Kilvington,et al.  In Vivo Hip Joint Forces Recorded on a Strain Gauged ‘English’ Prosthesis Using an Implanted Transmitter , 1981 .

[50]  W. Dewey,et al.  Thermal dose determination in cancer therapy. , 1984, International journal of radiation oncology, biology, physics.

[51]  Robert Langer,et al.  Wireless Power Transfer to Millimeter-Sized Gastrointestinal Electronics Validated in a Swine Model , 2017, Scientific Reports.

[52]  Frederick A Matsen,et al.  Nonprosthetic glenoid arthroplasty with humeral hemiarthroplasty and total shoulder arthroplasty yield similar self-assessed outcomes in the management of comparable patients with glenohumeral arthritis. , 2007, Journal of shoulder and elbow surgery.

[53]  Ieee Standards Board IEEE standard for safety levels with respect to human exposure to radio frequency electromagnetic fields, 3kHz to 300 GHz , 1992 .

[54]  A Rohlmann,et al.  An instrumented implant for in vivo measurement of contact forces and contact moments in the shoulder joint. , 2009, Medical engineering & physics.

[55]  B P Brockway,et al.  A new method for continuous chronic measurement and recording of blood pressure, heart rate and activity in the rat via radio-telemetry. , 1991, Clinical and experimental hypertension. Part A, Theory and practice.

[56]  Sudipto Chakraborty,et al.  Fully Wireless Implantable Cardiovascular Pressure Monitor Integrated with a Medical Stent , 2010, IEEE Transactions on Biomedical Engineering.

[57]  W. Ko,et al.  Novel Long-Term Implantable Blood Pressure Monitoring System with Reduced Baseline Drift , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[58]  N. Baker,et al.  ZigBee and Bluetooth strengths and weaknesses for industrial applications , 2005 .

[59]  G. Lazzi,et al.  A Comparison of Two and Three Dimensional Dipole Antennas for an Implantable Retinal Prosthesis , 2008, IEEE Transactions on Antennas and Propagation.

[60]  M. Myers,et al.  Assessment of miniaturized ultrasound-powered implants: an in vivo study , 2020, Journal of neural engineering.

[61]  G. Blake,et al.  Role of dual-energy X-ray absorptiometry in the diagnosis and treatment of osteoporosis. , 2007, Journal of clinical densitometry : the official journal of the International Society for Clinical Densitometry.

[62]  M. T. Lee,et al.  Implantable pacemakers , 1996, Proc. IEEE.

[63]  H. Mond,et al.  The 11th World Survey of Cardiac Pacing and Implantable Cardioverter‐Defibrillators: Calendar Year 2009–A World Society of Arrhythmia's Project , 2011, Pacing and clinical electrophysiology : PACE.

[64]  Brett S. Klosterhoff,et al.  Wireless sensor enables longitudinal monitoring of regenerative niche mechanics during rehabilitation that enhance bone repair. , 2020, Bone.

[65]  G. Zhu,et al.  Muscle‐Driven In Vivo Nanogenerator , 2010, Advanced materials.

[66]  Pedro P. Irazoqui,et al.  Far-Field RF Powering of Implantable Devices: Safety Considerations , 2013, IEEE Transactions on Biomedical Engineering.

[67]  M. Fornage,et al.  Heart Disease and Stroke Statistics—2017 Update: A Report From the American Heart Association , 2017, Circulation.

[68]  James C. Lin,et al.  A new IEEE standard for safety levels with respect to human exposure to radio-frequency radiation , 2006 .

[69]  Lauri Sydanheimo,et al.  SAR reduction and link optimization for mm-size remotely powered wireless implants using segmented loop antennas , 2011, 2011 IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems.

[70]  Cong Zhang,et al.  Design of LC-type passive wireless multi-parameter sensor , 2013, The 8th Annual IEEE International Conference on Nano/Micro Engineered and Molecular Systems.

[71]  Amin Arbabian,et al.  Long-term in vivo performance of novel ultrasound powered implantable devices , 2018, 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[72]  David Blaauw,et al.  Subcutaneous Photovoltaic Infrared Energy Harvesting for Bio-implantable Devices , 2017, IEEE Transactions on Electron Devices.

[73]  S. Vatner,et al.  Simultaneous comparison and calibration of the Doppler and electromagnetic flowmeters. , 1970, Journal of applied physiology.

[74]  Mehmet Rasit Yuce,et al.  A Wireless Implantable Sensor Design With Subcutaneous Energy Harvesting for Long-Term IoT Healthcare Applications , 2018, IEEE Access.

[75]  Desai Ss Early diagnosis of spinal tuberculosis by MRI , 1994 .

[76]  G. Engdahl Handbook of Giant Magnetostrictive Materials , 1999 .

[77]  D. D’Lima,et al.  An implantable telemetry device to measure intra-articular tibial forces. , 2005, Journal of biomechanics.

[78]  P J Nicholls,et al.  X-ray diagnosis of healing fractures in rabbits. , 1979, Clinical orthopaedics and related research.

[79]  John A Szivek,et al.  In vivo strain measurements from hardware and lamina during spine fusion. , 2005, Journal of biomedical materials research. Part B, Applied biomaterials.

[80]  Jianhua Zhu,et al.  A Passive and Wireless Sensor for Bone Plate Strain Monitoring , 2017, Sensors.

[81]  Joseph A. Paradiso,et al.  Parasitic power harvesting in shoes , 1998, Digest of Papers. Second International Symposium on Wearable Computers (Cat. No.98EX215).

[82]  G. Loeb,et al.  The BION devices: injectable interfaces with peripheral nerves and muscles. , 2006, Neurosurgical focus.

[83]  T. Meng,et al.  Optimal Frequency for Wireless Power Transmission Into Dispersive Tissue , 2010, IEEE Transactions on Antennas and Propagation.

[84]  Jackson T. Wright,et al.  2017 ACC/AHA/AAPA/ABC/ACPM/AGS/APhA/ASH/ASPC/NMA/PCNA Guideline for the Prevention, Detection, Evaluation, and Management of High Blood Pressure in Adults: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines. , 2018, Journal of the American College of Cardiology.

[85]  William T. Abraham,et al.  Impact of Practice-Based Management of Pulmonary Artery Pressures in 2000 Patients Implanted With the CardioMEMS Sensor , 2017, Circulation.

[86]  Gaetano Marrocco,et al.  Numerical and Experimental Characterization of Through-the-Body UHF-RFID Links for Passive Tags Implanted Into Human Limbs , 2014, IEEE Transactions on Antennas and Propagation.

[87]  Guang-Zhong Yang,et al.  From Wearable Sensors to Smart Implants-–Toward Pervasive and Personalized Healthcare , 2015, IEEE Transactions on Biomedical Engineering.

[88]  Craig A. Grimes,et al.  Design and application of a wireless, passive, resonant-circuit environmental monitoring sensor , 2001 .

[89]  Mehdi Kiani,et al.  Design and Optimization of Ultrasonic Wireless Power Transmission Links for Millimeter-Sized Biomedical Implants , 2017, IEEE Transactions on Biomedical Circuits and Systems.

[90]  Hoi-Jun Yoo,et al.  The Signal Transmission Mechanism on the Surface of Human Body for Body Channel Communication , 2012, IEEE Transactions on Microwave Theory and Techniques.

[91]  D Saloner,et al.  Assessment of carotid artery stenosis by MR angiography: comparison with x-ray angiography and color-coded Doppler ultrasound. , 1992, AJNR. American journal of neuroradiology.

[92]  Christoph Huber,et al.  The first batteryless, solar-powered cardiac pacemaker. , 2015, Heart rhythm.

[93]  M. Whooley,et al.  Elevated pulmonary artery pressure by Doppler echocardiography predicts hospitalization for heart failure and mortality in ambulatory stable coronary artery disease: the Heart and Soul Study. , 2007, Journal of the American College of Cardiology.

[94]  Brett S. Klosterhoff,et al.  Wireless implantable sensor for non-invasive, longitudinal quantification of axial strain across rodent long bone defects , 2017, bioRxiv.

[95]  Eric M. Yeatman,et al.  Ultrasonic vs. Inductive Power Delivery for Miniature Biomedical Implants , 2010, 2010 International Conference on Body Sensor Networks.

[96]  John O. Prior,et al.  Blood flow, flow reserve, and glucose utilization in viable and nonviable myocardium in patients with ischemic cardiomyopathy , 2013, European Journal of Nuclear Medicine and Molecular Imaging.

[97]  T. Campi,et al.  Wireless Power Transfer Charging System for AIMDs and Pacemakers , 2016, IEEE Transactions on Microwave Theory and Techniques.

[98]  J. S. Cole,et al.  An ultrasonic pulsed Doppler system for measuring blood flow in small vessels. , 1974, Journal of applied physiology.

[99]  Satoshi Kawata,et al.  An implantable power supply with an optically rechargeable lithium battery , 2001, IEEE Transactions on Biomedical Engineering.

[100]  Antonius Rohlmann,et al.  Total hip joint prosthesis for in vivo measurement of forces and moments. , 2010, Medical engineering & physics.

[101]  T. O'Donnell,et al.  Energy scavenging for long-term deployable wireless sensor networks. , 2008, Talanta.

[102]  G Elfström,et al.  Intravital wireless telemetry of axial forces in Harrington distraction rods in patients with idiopathic scoliosis. , 1971, The Journal of bone and joint surgery. American volume.

[103]  Keat Ghee Ong,et al.  Implantable Sensors for Regenerative Medicine. , 2017, Journal of biomechanical engineering.

[104]  S. Taylor,et al.  A telemetry system for measurement of forces in massive orthopaedic implants in vivo , 1996, Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[105]  Wei Zhang,et al.  Implantable and self-powered blood pressure monitoring based on a piezoelectric thinfilm: Simulated, in vitro and in vivo studies , 2016 .

[106]  R. Kohno,et al.  Wireless Communications for Body Implanted Medical Device , 2007, 2007 Asia-Pacific Microwave Conference.

[107]  H. Reid,et al.  Segmental blood flow and rheological determinants in diabetic patients with peripheral occlusive arterial disease. , 2008, Journal of diabetes and its complications.

[108]  Albert Kim,et al.  Omnidirectional Ultrasonic Powering for Millimeter-Scale Implantable Devices , 2015, IEEE Transactions on Biomedical Engineering.

[109]  Man-Kay Law,et al.  A Single-Chip Solar Energy Harvesting IC Using Integrated Photodiodes for Biomedical Implant Applications , 2017, IEEE Transactions on Biomedical Circuits and Systems.

[110]  Fadel Adib,et al.  Enabling deep-tissue networking for miniature medical devices , 2018, SIGCOMM.

[111]  J. Blankensteijn,et al.  Noninvasive Intrasac Pressure Measurement and the Influence of Type 2 and Type 3 Endoleaks in an Animal Model of Abdominal Aortic Aneurysm , 2004, Vascular.

[112]  Sihong Wang,et al.  In Vivo Powering of Pacemaker by Breathing‐Driven Implanted Triboelectric Nanogenerator , 2014, Advanced materials.

[113]  R W Mann,et al.  A radio telemetry device for monitoring cartilage surface pressures in the human hip. , 1974, IEEE transactions on bio-medical engineering.

[114]  C Hirsch,et al.  The introduction of force measurements guiding instrumental correction of scoliosis. , 1968, Acta orthopaedica Scandinavica.

[115]  M. Turakhia,et al.  Cost-Effectiveness of Implantable Pulmonary Artery Pressure Monitoring in Chronic Heart Failure. , 2016, JACC. Heart failure.

[116]  A. Dagan,et al.  Disability Progression in Multiple Sclerosis Is Affected by the Emergence of Comorbid Arterial Hypertension , 2016, Journal of clinical neurology.

[117]  Y. Tai,et al.  Wireless Intraocular Pressure Sensing Using Microfabricated Minimally Invasive Flexible-Coiled LC Sensor Implant , 2010, Journal of Microelectromechanical Systems.

[118]  S S Desai,et al.  Early diagnosis of spinal tuberculosis by MRI. , 1994, The Journal of bone and joint surgery. British volume.

[119]  Christoph Huber,et al.  Successful pacing using a batteryless sunlight-powered pacemaker. , 2014, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[120]  F. Burny [Study of consolidation of fractures by deformation gauges in clinical medicine]. , 1968, Acta orthopaedica Belgica.

[121]  Andrew J. DeRouin,et al.  A Varactor-Based, Inductively Coupled Wireless pH Sensor , 2011, IEEE Sensors Journal.

[122]  Timothy McClure,et al.  Development of a fully implantable wireless pressure monitoring system , 2009, Biomedical microdevices.

[123]  John A Rogers,et al.  Conformal piezoelectric energy harvesting and storage from motions of the heart, lung, and diaphragm , 2014, Proceedings of the National Academy of Sciences.

[124]  Georg Bergmann,et al.  Implantable Sensor Technology: From Research to Clinical Practice , 2012, The Journal of the American Academy of Orthopaedic Surgeons.

[125]  J L Cunningham,et al.  Measuring stiffness can define healing of tibial fractures. , 1994, The Journal of bone and joint surgery. British volume.