Collection efficiency of a single optical fiber in turbid media.

If a single optical fiber is used for both delivery and collection of light, two major factors affect the measurement of collected light: (1) the light transport in the medium that describes the amount of light that returns to the fiber and (2) the light coupling to the optical fiber that depends on the angular distribution of photons entering the fiber. We focus on the importance of the latter factor and describe how the efficiency of the coupling depends on the optical properties of the medium. For highly scattering tissues, the efficiency is well predicted by the numerical aperture (NA) of the fiber. For lower scattering, such as in soft tissues, photons arrive at the fiber from deeper depths, and the coupling efficiency could increase twofold to threefold above that predicted by the NA.

[1]  P. Monnier,et al.  Clinical determination of tissue optical properties by endoscopic spatially resolved reflectometry. , 1996, Applied optics.

[2]  S L Jacques,et al.  Fluorescence spectroscopy of tissue: recovery of intrinsic fluorescence from measured fluorescence. , 1996, Applied optics.

[3]  S. Prahl Light transport in tissue , 1988 .

[4]  T. P. Moffitt,et al.  Sized-fiber reflectometry for measuring local optical properties , 2001 .

[5]  S L Jacques,et al.  Optical properties of intralipid: A phantom medium for light propagation studies , 1992, Lasers in surgery and medicine.

[6]  H. Sterenborg,et al.  Quantification of the hematoporphyrin derivative by fluorescence measurementusing dual-wavelength excitation anddual-wavelength detection. , 1993, Applied optics.

[7]  R. Rava,et al.  Analytical model for extracting intrinsic fluorescence in turbid media. , 1993, Applied optics.

[8]  Henricus J. C. M. Sterenborg,et al.  Two integrating spheres with an intervening scattering sample , 1992 .

[9]  P. Monnier,et al.  Optimizing light dosimetry in photodynamic therapy of early stage carcinomas of the esophagus using fluorescence spectroscopy , 1996, Lasers in surgery and medicine.

[10]  I. S. Saidi,et al.  Transcutaneous Optical Measurement of Hyperbilirubinemia in Neonates , 1992 .

[11]  G. Wagnières,et al.  Clinical pharmacokinetic studies of photofrin by fluorescence spectroscopy in the oral cavity, the esophagus, and the bronchi , 1995, Cancer.

[12]  B W Pogue,et al.  Fiber-optic bundle design for quantitative fluorescence measurement from tissue. , 1998, Applied optics.

[13]  A. Welch,et al.  A review of the optical properties of biological tissues , 1990 .

[14]  J. Mourant,et al.  Particle size analysis of turbid media with a single optical fiber in contact with the medium to deliver and detect white light. , 2001, Applied optics.

[15]  S. Jacques,et al.  Light distributions in artery tissue: Monte Carlo simulations for finite‐diameter laser beams , 1989, Lasers in surgery and medicine.

[16]  L Wang,et al.  MCML--Monte Carlo modeling of light transport in multi-layered tissues. , 1995, Computer methods and programs in biomedicine.

[17]  B. Pogue,et al.  Fluorophore quantitation in tissue-simulating media with confocal detection , 1996 .