Finite element analysis for the evaluation of the structural behaviour, of a prosthesis for trans-tibial amputees.
暂无分享,去创建一个
Tomáš Návrat | David Paloušek | Milan Omasta | Jiří Rosický | M. Omasta | J. Rosický | D. Paloušek | T. Návrat
[1] Xiaohong Jia,et al. Effects of Shoe Heel Height on Loading and Muscle Activity for Trans-Tibial Amputees During Standing * , 2009 .
[2] Alan Turner-Smith,et al. The influence of the length of lower-limb prosthesis on spinal kinematics. , 2003, Archives of physical medicine and rehabilitation.
[3] Steven A. Gard,et al. Use of Quantitative Gait Analysis for the Evaluation of Prosthetic Walking Performance , 2006 .
[4] W. Lee,et al. Load transfer mechanics between trans-tibial prosthetic socket and residual limb--dynamic effects. , 2004, Journal of biomechanics.
[5] G Simpson,et al. Modeling the interactions between a prosthetic socket, polyurethane liners and the residual limb in transtibial amputees using non-linear finite element analysis. , 2001, Biomedical sciences instrumentation.
[6] Necip Berme,et al. The limitations of inverse dynamics for the analysis of below-knee amputee gait with a dynamic elastic response prosthesis , 1997 .
[7] Gordon Bennett,et al. Finite Element Analysis as a Tool for Parametric Prosthetic Foot Design and Evaluation. Technique Development in the Solid Ankle Cushioned Heel (SACH) Foot , 2003, Computer methods in biomechanics and biomedical engineering.
[8] A. Holmes,et al. The Effect of Prosthesis Alignment on the Symmetry of Gait in Subjects with Unilateral Transtibial Amputation , 2006, Prosthetics and orthotics international.
[9] S G Zachariah,et al. Finite element estimates of interface stress in the trans-tibial prosthesis using gap elements are different from those using automated contact. , 2000, Journal of biomechanics.
[10] Peter M. Quesada,et al. The use of direct measurement of ankle kinetics in the calculation of energy storage and return in a dynamic elastic response prosthesis , 1998 .
[11] H B Skinner,et al. Analysis of a below-knee patellar tendon-bearing prosthesis: a finite element study. , 1991, Journal of rehabilitation research and development.
[12] Sean R. Mitchell,et al. Virtual modelling of a prosthetic foot to improve footwear testing , 2006 .
[13] M Zhang,et al. Finite element modelling of a residual lower-limb in a prosthetic socket: a survey of the development in the first decade. , 1998, Medical engineering & physics.
[14] V. C. Roberts,et al. Development of a non-linear finite element modelling of the below-knee prosthetic socket interface. , 1995, Medical engineering & physics.
[15] Ming Zhang,et al. Finite-element analysis to determine effect of monolimb flexibility on structural strength and interaction between residual limb and prosthetic socket. , 2004, Journal of rehabilitation research and development.
[16] Sandra J. Olney,et al. Effect of the Weight of Prosthetic Components on the Gait of Transtibial Amputees , 2004 .
[17] Nian-Zhong Chen,et al. A numerical approach to evaluate the fatigue life of monolimb. , 2006, Medical engineering & physics.
[18] Nian-Zhong Chen,et al. A robust design procedure for improvement of quality of lower-limb prosthesis. , 2006, Bio-medical materials and engineering.
[19] Zhang Ming,et al. The Influence of Dynamic Trans-tibial Prosthetic Alignment on Standing Plantar Foot Pressure , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.
[20] M D Geil,et al. Plantar foot pressure responses to changes during dynamic trans-tibial prosthetic alignment in a clinical setting , 2004, Prosthetics and orthotics international.
[21] Xiaohong Jia,et al. Finite element modeling of the contact interface between trans-tibial residual limb and prosthetic socket. , 2004, Medical engineering & physics.
[22] E. Isakov,et al. The influence of prosthetic foot alignment on trans-tibial amputee gait , 2003, Prosthetics and orthotics international.
[23] Li Xiaobing,et al. Influence of Shoe-heel Height of the Trans-tibial Prosthesis on Static Standing Biomechanics , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.
[24] D S Childress,et al. Parametric analysis using the finite element method to investigate prosthetic interface stresses for persons with trans-tibial amputation. , 1996, Journal of rehabilitation research and development.
[25] H. Seelen,et al. Effects of prosthesis alignment on pressure distribution at the stump/socket interface in transtibial amputees during unsupported stance and gait , 2003, Clinical rehabilitation.
[26] O. Friberg,et al. Biomechanical significance of the correct length of lower limb prostheses: A clinical and radiological study , 1984, Prosthetics and orthotics international.
[27] Ming Zhang,et al. Fatigue Test of Low-Cost Flexible-Shank Monolimb Trans-Tibial Prosthesis , 2006, Prosthetics and orthotics international.
[28] A. Grishman. Biomedical sciences instrumentation , 1964 .
[29] Tomáš Návrat,et al. Experimental Recognition of Loading Character of Transtibial Prosthesis , 2008 .
[30] J. M. Carlson,et al. Functional Limitations From Pain Caused by Repetitive Loading on the Skin: A Review and Discussion for Practitioners, With New Data for Limiting Friction Loads , 2006 .
[31] Pil Kang,et al. Pressure Distribution in Stump/Socket Interface in Response to Socket Flexion Angle Changes in Trans-Tibial Prostheses With Silicone Liner , 2006 .
[32] G K Klute,et al. Modelling the effect of prosthetic feet and shoes on the heel-ground contact force in amputee gait , 2004, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.