Impact of “high” implantation on functionality of self‐expandable bioprosthesis during the short‐ and long‐term outcome of patients who undergo transcatheter aortic valve implantation: Is high implantation beneficial?

AIM High position of the self-expandable bioprosthesis CoreValve/Evolut R has been proved to affect immediate hemodynamics of the valve. Whether this may have any impact on long-term procedural outcome has not been defined yet. The purpose of this study was to assess whether the final position of aortic bioprosthesis affects its long-term functionality. METHOD Consecutive patients (pts) who underwent successful TAVI procedure were evaluated and separated into 2 groups according to the implantation depth (ID): Group I: pts with 4 mm <ID ≤13 mm; Group II: pts with ID ≤4 mm. ID was measured utilizing the final aortography after device delivery and was defined as the distance both from the native non- and left coronary cusp to the deepest edge of the deployed bioprosthesis in the left ventricle. Clinical outcome and echocardiographic parameters were recorded before the procedure, at discharge, at 1-month and 1-year-follow-up. RESULTS One hundred and ninety-eight pts (80 ± 5.5 years, 107 males [54%]) treated with the CoreValve/Evolut R bioprostheses were recorded. Group I appeared to have higher peak gradient (17 ± 6.5 vs 14 ± 5.5 mm Hg, P = .02) as well as Vmax (2 ± 0.4 vs 1.84 ± 0.38 m/s, P = .02) at follow-up after 1 year when compared with Group II (ID <4 mm). Grouping for ID did not affect all-cause 1-year mortality. Paravalvular aortic regurgitation, as well as LVEF at discharge, proved to be independent predictors of all-cause 1-year mortality when adjusted for cofactors. CONCLUSION Implantation depth under 4 mm seems to have a favorable effect on long-term hemodynamic valve functionality.

[1]  Prem A. Midha,et al.  The Fluid Mechanics of Transcatheter Heart Valve Leaflet Thrombosis in the Neosinus , 2017, Circulation.

[2]  G. Stone,et al.  Natural history of subclinical leaflet thrombosis affecting motion in bioprosthetic aortic valves , 2017, European heart journal.

[3]  P. Stella,et al.  Transcatheter aortic valve implantation in low ejection fraction/low transvalvular gradient patients: the rule of 40 , 2017, Journal of cardiovascular medicine.

[4]  H. Takagi,et al.  Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Implantation. , 2016, The Annals of thoracic surgery.

[5]  A. Ducci,et al.  Possible Subclinical Leaflet Thrombosis in Bioprosthetic Aortic Valves. , 2016, The New England journal of medicine.

[6]  K. Goel,et al.  Meta-Analysis of the Prognostic Impact of Stroke Volume, Gradient, and Ejection Fraction After Transcatheter Aortic Valve Implantation. , 2015, The American journal of cardiology.

[7]  A. Colombo,et al.  5-Year Outcomes After Transcatheter Aortic Valve Implantation With CoreValve Prosthesis. , 2015, JACC. Cardiovascular interventions.

[8]  P. Lemos,et al.  Outcomes and predictors of mortality after transcatheter aortic valve implantation: Results of the Brazilian registry , 2015, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[9]  K. Kuck,et al.  Clinical impact of paravalvular leaks on biomarkers and survival after transcatheter aortic valve implantation , 2015, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[10]  M. Pasic,et al.  Transcatheter aortic valve implantation in failed bioprosthetic surgical valves. , 2014, JAMA.

[11]  P. Leprince,et al.  Postprocedural Aortic Regurgitation in Balloon-Expandable and Self-Expandable Transcatheter Aortic Valve Replacement Procedures: Analysis of Predictors and Impact on Long-Term Mortality Insights From the FRANCE2 Registry , 2014, Circulation.

[12]  Susheel Kodali,et al.  Two-Year Outcomes After Transcatheter or Surgical Aortic Valve Replacement , 2013 .

[13]  I. Meredith,et al.  Relationship of aortic annular eccentricity and paravalvular regurgitation post transcatheter aortic valve implantation with CoreValve. , 2013, The Journal of invasive cardiology.

[14]  Anson Cheung,et al.  5-year outcome after transcatheter aortic valve implantation. , 2013, Journal of the American College of Cardiology.

[15]  S. Achenbach,et al.  SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR). , 2012, Journal of cardiovascular computed tomography.

[16]  A. Mügge,et al.  Heart failure in severe aortic valve stenosis: prognostic impact of left ventricular ejection fraction and mean gradient on outcome after transcatheter aortic valve implantation , 2012, European journal of heart failure.

[17]  P. Leprince,et al.  Registry of transcatheter aortic-valve implantation in high-risk patients. , 2012, The New England journal of medicine.

[18]  Scott Lim,et al.  Two-year outcomes after transcatheter or surgical aortic-valve replacement. , 2012, The New England journal of medicine.

[19]  L. Buellesfeld,et al.  A permanent solution for a temporary problem: transcatheter valve-in-valve implantation for failed transcatheter aortic valve replacement. , 2012, JACC. Cardiovascular interventions.

[20]  M. Morice,et al.  Impact of CT-guided valve sizing on post-procedural aortic regurgitation in transcatheter aortic valve implantation. , 2012, EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology.

[21]  G. Richardt,et al.  A case of rotational atherectomy after implantation of the Medtronic CoreValve bioprosthesis , 2012, Clinical Research in Cardiology.

[22]  M. Mack,et al.  Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document (VARC-2). , 2012, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[23]  G. Schuler,et al.  Aortic regurgitation after transcatheter aortic valve implantation: incidence and early outcome. Results from the German transcatheter aortic valve interventions registry , 2011, Heart.

[24]  F. Maisano,et al.  Incidence and Predictors of Early and Late Mortality After Transcatheter Aortic Valve Implantation in 663 Patients With Severe Aortic Stenosis , 2011, Circulation.

[25]  Friedhelm Beyersdorf,et al.  Assessment of aortic annulus dimensions for Edwards SAPIEN Transapical Heart Valve implantation by computed tomography: calculating average diameter using a virtual ring method. , 2010, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[26]  R. Tölg,et al.  Anatomic and procedural predictors of paravalvular aortic regurgitation after implantation of the Medtronic CoreValve bioprosthesis. , 2010, Journal of the American College of Cardiology.

[27]  C. Stefanadis,et al.  Transcatheter aortic valve implantation, patient selection process and procedure: two centres' experience of the intervention without general anaesthesia. , 2010, Hellenic journal of cardiology : HJC = Hellenike kardiologike epitheorese.

[28]  Patrick W Serruys,et al.  Cardiac CT: necessary for precise sizing for transcatheter aortic implantation. , 2010, EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology.

[29]  Fabien Hyafil,et al.  Multimodal assessment of the aortic annulus diameter: implications for transcatheter aortic valve implantation. , 2010, Journal of the American College of Cardiology.

[30]  Volkmar Falk,et al.  Valve-in-a-valve concept for transcatheter minimally invasive repeat xenograft implantation. , 2007, Journal of the American College of Cardiology.

[31]  Helmut Baumgartner,et al.  Guidelines on the management of valvular heart disease The Task Force on the Management of Valvular Heart Disease of the European Society of Cardiology , 2007 .

[32]  R. Detrano,et al.  Quantification of coronary artery calcium using ultrafast computed tomography. , 1990, Journal of the American College of Cardiology.

[33]  J. R. Landis,et al.  The measurement of observer agreement for categorical data. , 1977, Biometrics.

[34]  C. Lillehei,et al.  LEFT RETROGRADE CARDIOANGIOGRAPHY IN ACQUIRED CARDIAC DISEASE: TECHNIC, INDICATIONS AND INTERPRETATIONS IN 700 CASES. , 1964, The American journal of cardiology.