Development of the two Korean adult tomographic computational phantoms for organ dosimetry.

Following the previously developed Korean tomographic phantom, KORMAN, two additional whole-body tomographic phantoms of Korean adult males were developed from magnetic resonance (MR) and computed tomography (CT) images, respectively. Two healthy male volunteers, whose body dimensions were fairly representative of the average Korean adult male, were recruited and scanned for phantom development. Contiguous whole body MR images were obtained from one subject exclusive of the arms, while whole-body CT images were acquired from the second individual. A total of 29 organs and tissues and 19 skeletal sites were segmented via image manipulation techniques such as gray-level thresholding, region growing, and manual drawing, in which each of segmented image slice was subsequently reviewed by an experienced radiologist for anatomical accuracy. The resulting phantoms, the MR-based KTMAN-1 (Korean Typical MAN-1) and the CT-based KTMAN-2 (Korean Typical MAN-2), consist of 300 X 150 X 344 voxels with a voxel resolution of 2 X 2 X 5 mm3 for both phantoms. Masses of segmented organs and tissues were calculated as the product of a nominal reference density, the prevoxel volume, and the cumulative number of voxels defining each organs or tissue. These organs masses were then compared with those of both the Asian and the ICRP reference adult male. Organ masses within both KTMAN-1 and KTMAN-2 showed differences within 40% of Asian and ICRP reference values, with the exception of the skin, gall bladder, and pancreas which displayed larger differences. The resulting three-dimensional binary file was ported to the Monte Carlo code MCNPX2.4 to calculate organ doses following external irradiation for illustrative purposes. Colon, lung, liver, and stomach absorbed doses, as well as the effective dose, for idealized photon irradiation geometries (anterior-posterior and right lateral) were determined, and then compared with data from two other tomographic phantoms (Asian and Caucasian), and stylized ORNL phantom. The armless KTMAN-1 can be applied to dosimetry for computed tomography or lateral x-ray examination, while the whole body KTMAN-2 can be used for radiation protection dosimetry.

[1]  G Drexler,et al.  The construction of computer tomographic phantoms and their application in radiology and radiation protection , 1988, Radiation and environmental biophysics.

[2]  A. Bozkurt,et al.  VIP-MAN: AN IMAGE-BASED WHOLE-BODY ADULT MALE MODEL CONSTRUCTED FROM COLOR PHOTOGRAPHS OF THE VISIBLE HUMAN PROJECT FOR MULTI-PARTICLE MONTE CARLO CALCULATIONS , 2000, Health physics.

[3]  T. Nagaoka,et al.  Development of realistic high-resolution whole-body voxel models of Japanese adult males and females of average height and weight, and application of models to radio-frequency electromagnetic-field dosimetry. , 2004, Physics in medicine and biology.

[4]  X. Xu,et al.  Fluence-to-dose conversion coefficients for monoenergetic proton beams based on the VIP-Man anatomical model. , 2004, Radiation protection dosimetry.

[5]  J. W. Vieira,et al.  All about FAX: a Female Adult voXel phantom for Monte Carlo calculation in radiation protection dosimetry. , 2003, Physics in medicine and biology.

[6]  K. Eckerman,et al.  Reference Man Models for Males and Females of Six Age Groups of Asian Populations , 1998 .

[7]  X. Xu,et al.  Organ dose conversion coefficients for 0.1-10 MeV electrons calculated for the VIP-Man tomographic model. , 2001, Health physics.

[8]  X. Xu,et al.  Conversion coefficients based on the VIP-Man anatomical model and EGS4. , 2001, Health physics.

[9]  P B Hoffer,et al.  Computerized three-dimensional segmented human anatomy. , 1994, Medical physics.

[10]  D. G. Jones A Realistic Anthropomorphic Phantom for Calculating Organ Doses Arising from External Photon Irradiation , 1997 .

[11]  P. Dimbylow,et al.  Fine resolution calculations of SAR in the human body for frequencies up to 3 GHz. , 2002, Physics in medicine and biology.

[12]  M. Zankl,et al.  The adult male voxel model ”Golem” segmented from whole-body CT patient data , 2001, Radiation and environmental biophysics.

[13]  Choonsik Lee,et al.  Korean adult male voxel model KORMAN segmented from magnetic resonance images. , 2004, Medical physics.

[14]  Martin Caon,et al.  Voxel-based computational models of real human anatomy: a review , 2004, Radiation and environmental biophysics.

[15]  M Caon,et al.  An EGS4-ready tomographic computational model of a 14-year-old female torso for calculating organ doses from CT examinations. , 1999, Physics in medicine and biology.

[16]  P. Dimbylow FDTD calculations of the whole-body averaged SAR in an anatomically realistic voxel model of the human body from 1 MHz to 1 GHz. , 1997, Physics in medicine and biology.

[17]  N Petoussi-Henss,et al.  Organ dose conversion coefficients for external photon irradiation of male and female voxel models , 2002, Physics in medicine and biology.

[18]  X. Xu,et al.  Fluence-to-dose conversion coefficients from monoenergetic neutrons below 20 MeV based on the VIP-Man anatomical model , 2000, Physics in medicine and biology.

[19]  M Zankl,et al.  Construction of a computed tomographic phantom for a Japanese male adult and dose calculation system , 2001, Radiation and environmental biophysics.

[20]  Keith F. Eckerman,et al.  Mathematical models and specific absorbed fractions of photon energy in the nonpregnant adult female and at the end of each trimester of pregnancy , 1995 .

[21]  D. G. Jones A Realistic Anthrompomorphic Phantom for Calculating Specific Absorbed Fractions of Energy Deposited from Internal Gamma Emitters , 1998 .

[22]  N Petoussi-Henss,et al.  The application of voxel phantoms to the internal dosimetry of radionuclides. , 2003, Radiation protection dosimetry.

[23]  Wesley E Bolch,et al.  The UF series of tomographic computational phantoms of pediatric patients. , 2005, Medical physics.

[24]  P. Dimbylow,et al.  Induced current densities from low-frequency magnetic fields in a 2 mm resolution, anatomically realistic model of the body. , 1998, Physics in medicine and biology.

[25]  W E Bolch,et al.  Creation of two tomographic voxel models of paediatric patients in the first year of life. , 2002, Physics in medicine and biology.

[26]  N Petoussi-Henss,et al.  ADULT FEMALE VOXEL MODELS OF DIFFERENT STATURE AND PHOTON CONVERSION COEFFICIENTS FOR RADIATION PROTECTION , 2004, Health physics.

[27]  T. S. Chen,et al.  Patient risk from interproximal radiography. , 1984, Oral surgery, oral medicine, and oral pathology.