Transient gene expression in CHO cells monitored with automated flow cytometry

Transient gene expression is frequently used in industry to rapidly generate usable quantities of a protein from cultured cells. In gene therapy applications it is used to express a therapeutic protein in vivo. A quantitative assessment of the expression kinetics is important because it enables optimization and control of culture conditions for higher productivity. Previous experimental studies show a characteristic peak in average protein expression per cell after transfection followed by an exponential decrease of the expressed protein. Here, we show that the exponential decrease in single cell expression of enhanced Green Fluorescent Protein (eGfp) occurs in discrete steps. We attribute this to the absence of plasmid replication and to symmetric partitioning of plasmid and eGfp between dividing cells. This is reflected in the total eGfp in the bioreactor, which increased at a constant rate throughout the experiment. Additionally, the data provide a detailed time course of cell physiology during recovery from electroporation. The time course of cell physiology precisely indicates when the culture shifts growth phases. Furthermore, the data indicate two unique stationary phases. One type of stationary phase occurs when proliferation ceases while cells decrease their cell size, maintain granularity, and mean eGfp content decreases. The second type occurs when proliferation ceases while cells increase their cell size, increase granularity, and surprisingly maintain eGfp content. The collected data demonstrate the utility of automated flow cytometry for unique bioreactor monitoring and control capabilities in accordance with the US Food and Drug Administration’s Process Analytical Technology initiative.

[1]  S. Novaković,et al.  Setting optimal parameters for in vitro electrotransfection of B16F1, SA1, LPB, SCK, L929 and CHO cells using predefined exponentially decaying electric pulses. , 2003, Bioelectrochemistry.

[2]  Martin Raff,et al.  Differences in the way a mammalian cell and yeast cells coordinate cell growth and cell-cycle progression , 2003, Journal of biology.

[3]  J. Teissié,et al.  Osmotically induced membrane tension facilitates the triggering of living cell electropermeabilization. , 2004, Bioelectrochemistry.

[4]  Muriel Golzio,et al.  Cell synchronization effect on mammalian cell permeabilization and gene delivery by electric field. , 2002, Biochimica et biophysica acta.

[5]  Mojca Pavlin,et al.  Effect of electric field induced transmembrane potential on spheroidal cells: theory and experiment , 2003, European Biophysics Journal.

[6]  F. Srienc,et al.  A flow injection flow cytometry system for on-line monitoring of bioreactors. , 1999, Biotechnology and bioengineering.

[7]  K. Iatrou,et al.  Use of flow cytometry to rapidly optimize the transfection of animal cells. , 2000, BioTechniques.

[8]  Friedrich Srienc,et al.  Single-cell variability in growing Saccharomyces cerevisiae cell populations measured with automated flow cytometry. , 2004, Journal of biotechnology.

[9]  Friedrich Srienc,et al.  Dynamics of single cell property distributions in Chinese hamster ovary cell cultures monitored and controlled with automated flow cytometry. , 2005, Journal of biotechnology.

[10]  Friedrich Srienc,et al.  Automated flow cytometry for acquisition of time‐dependent population data , 2003, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[11]  F. Wurm,et al.  Serum‐free large‐scale transient transfection of CHO cells , 2004, Biotechnology and bioengineering.