Measurements and clinical consequences of prostate motion during a radiotherapy fraction.

PURPOSE Here we study the magnitude of prostate motion during the delivery of a radiotherapy fraction. These motions have clinical consequences for on-line position verification and the choice of margins around the target volume. METHODS AND MATERIALS We studied the motion of the prostate for 10 patients during 251 radiotherapy treatment fractions by assessing the position of implanted gold markers. Gold markers of 1 mm diameter and 5 mm length were implanted in the prostate before the start of the radiotherapy. We obtained movies during each fraction using an a-Si flat-panel imager. The markers could be detected in separate frames using a marker extraction kernel. RESULTS Marker displacements as large as 9.5 mm were detected in one fraction. The motion of the prostate is greatest in the caudal-cranial and the anterior-posterior directions. Within a time window of 2 to 3 min, deviations from the initial marker position, averaged over all patients, are 0.3 +/- 0.5 mm and -0.4 +/- 0.7 mm in the anterior-posterior and caudal-cranial directions, respectively. CONCLUSIONS It appeared that on average, the intrafraction prostate motions did not result in margins larger than 1 mm, provided that the position verification is performed at time intervals of 2 to 3 min. Only for some patients performing more frequent position verification or adding extra margins of 2 to 3 mm is required to account for intrafraction prostate motions.

[1]  J Pouliot,et al.  Electronic portal imaging device detection of radioopaque markers for the evaluation of prostate position during megavoltage irradiation: a clinical study. , 1997, International journal of radiation oncology, biology, physics.

[2]  M van Herk,et al.  Quantification of organ motion during conformal radiotherapy of the prostate by three dimensional image registration. , 1995, International journal of radiation oncology, biology, physics.

[3]  D P Dearnaley,et al.  Evaluating the effect of rectal distension and rectal movement on prostate gland position using cine MRI. , 1999, International journal of radiation oncology, biology, physics.

[4]  P. Bergström,et al.  High-precision conformal radiotherapy (HPCRT) of prostate cancer--a new technique for exact positioning of the prostate at the time of treatment. , 1998, International journal of radiation oncology, biology, physics.

[5]  P Hofman,et al.  Detection of fiducial gold markers for automatic on-line megavoltage position verification using a marker extraction kernel (MEK). , 2000, International journal of radiation oncology, biology, physics.

[6]  J Szanto,et al.  Respiratory-induced prostate motion: quantification and characterization. , 2000, International journal of radiation oncology, biology, physics.

[7]  K Lam,et al.  Measurement of prostate movement over the course of routine radiotherapy using implanted markers. , 1995, International journal of radiation oncology, biology, physics.

[8]  H. Shirato,et al.  Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor. , 2000, International journal of radiation oncology, biology, physics.

[9]  D Yan,et al.  An off-line strategy for constructing a patient-specific planning target volume in adaptive treatment process for prostate cancer. , 2000, International journal of radiation oncology, biology, physics.

[10]  H Shirato,et al.  Use of an implanted marker and real-time tracking of the marker for the positioning of prostate and bladder cancers. , 2000, International journal of radiation oncology, biology, physics.

[11]  K. Langen,et al.  Organ motion and its management. , 2001, International journal of radiation oncology, biology, physics.

[12]  T E Schultheiss,et al.  Ultrasound-based stereotactic guidance in prostate cancer--quantification of organ motion and set-up errors in external beam radiation therapy. , 2000, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[13]  M. V. van Herk,et al.  The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy. , 2000, International journal of radiation oncology, biology, physics.

[14]  P Hofman,et al.  Feasibility of automatic marker detection with an a-Si flat-panel imager. , 2001, Physics in medicine and biology.

[15]  D A Jaffray,et al.  Managing geometric uncertainty in conformal intensity-modulated radiation therapy. , 1999, Seminars in radiation oncology.

[16]  J M Balter,et al.  A comparison of ventilatory prostate movement in four treatment positions. , 2000, International journal of radiation oncology, biology, physics.

[17]  J C Stroom,et al.  Detection of internal organ movement in prostate cancer patients using portal images. , 2000, Medical physics.