Fluence-to-dose conversion coefficients based on the posture modification of Adult Male (AM) and Adult Female (AF) reference phantoms of ICRP 110

Abstract The aim of this work was to modify the standing posture of the anthropomorphic reference phantoms of ICRP publication 110, AM (Adult Male) and AF (Adult Female), to the sitting posture. The change of posture was performed using the Visual Monte Carlo software (VMC) to rotate the thigh region of the phantoms and position it between the region of the leg and trunk. Scion Image software was used to reconstruct and smooth the knee and hip contours of the phantoms in a sitting posture. For 3D visualization of phantoms, the VolView software was used. In the change of postures, the organ and tissue masses were preserved. The MCNPX was used to calculate the equivalent and effective dose conversion coefficients (CCs) per fluence for photons for six irradiation geometries suggested by ICRP publication 110 (AP, PA, RLAT, LLAT, ROT and ISO) and energy range 0.010–10 MeV. The results were compared between the standing and sitting postures, for both sexes, in order to evaluate the differences of scattering and absorption of radiation for different postures. Significant differences in the CCs for equivalent dose were observed in the gonads, colon, prostate, urinary bladder and uterus, which are present in the pelvic region, and in organs distributed throughout the body, such as the lymphatic nodes, muscle, skeleton and skin, for the phantoms of both sexes. CCs for effective dose showed significant differences of up to 16% in the AP irradiation geometry, 27% in the PA irradiation geometry and 13% in the ROT irradiation geometry. These results demonstrate the importance of using phantoms in different postures in order to obtain more precise conversion coefficients for a given exposure scenario.

[1]  J. Valentin Basic anatomical and physiological data for use in radiological protection: reference values , 2002, Annals of the ICRP.

[2]  Martin Caon,et al.  Voxel-based computational models of real human anatomy: a review , 2004, Radiation and environmental biophysics.

[3]  R. Sievert,et al.  Book Reviews : Recommendations of the International Commission on Radiological Protection (as amended 1959 and revised 1962). I.C.R.P. Publication 6. 70 pp. PERGAMON PRESS. Oxford, London and New York, 1964. £1 5s. 0d. [TB/54] , 1964 .

[4]  Habib Zaidi,et al.  Computational anthropomorphic models of the human anatomy: the path to realistic Monte Carlo modeling in radiological sciences. , 2007, Annual review of biomedical engineering.

[5]  Choonsik Lee,et al.  Effective dose conversion coefficients for health care provider exposed to pediatric and adult victims in radiological dispersal device incident , 2015, Journal of radiological protection : official journal of the Society for Radiological Protection.

[6]  T. S. Chen,et al.  Patient risk from interproximal radiography. , 1984, Oral surgery, oral medicine, and oral pathology.

[7]  N Petoussi-Henss,et al.  Conversion Coefficients for Radiological Protection Quantities for External Radiation Exposures , 2010, Annals of the ICRP.

[8]  John Hunt,et al.  Comparison of conversion coefficients for equivalent dose in terms of air kerma using a sitting and standing female adult voxel simulators exposure to photons in antero-posterior irradiation geometry , 2014 .

[9]  J. Hunt,et al.  Comparison of conversion coefficients for equivalent dose in terms of air kerma for photons using a male adult voxel simulator in sitting and standing posture with geometry of irradiation antero-posterior , 2014 .

[10]  Choonsik Lee,et al.  Organ and effective dose conversion coefficients for a sitting female hybrid computational phantom exposed to monoenergetic protons in idealized irradiation geometries , 2014, Physics in medicine and biology.

[11]  F. Vanhavere,et al.  MaMP and FeMP: computational mesh phantoms applied for studying the variation of WBC efficiency using a NaI(Tl) detector , 2014, Journal of radiological protection : official journal of the Society for Radiological Protection.

[12]  X George Xu,et al.  An exponential growth of computational phantom research in radiation protection, imaging, and radiotherapy: a review of the fifty-year history , 2014, Physics in medicine and biology.

[13]  X. Xu Computational Phantoms for Radiation Dosimetry: A 40-Year History of Evolution , 2009 .

[14]  W. S. Snyder,et al.  Estimates of absorbed fractions for monoenergetic photon sources uniformly distributed in various organs of a heterogeneous phantom. , 1974, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[15]  Jack Valentin,et al.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103. , 2007, Annals of the ICRP.

[16]  J G Hunt,et al.  The validation of organ dose calculations using voxel phantoms and Monte Carlo methods applied to point and water immersion sources. , 2004, Radiation protection dosimetry.