Cavitational mechanisms in ultrasound-accelerated fibrinolysis.

The role of both inertial and stable cavitation was investigated during in vitro ultrasound-accelerated fibrinolysis by recombinant tissue plasminogen activator (rt-PA) in the presence and absence of Optison. A unique treatment configuration applied ultrasound, rt-PA and Optison to the interior of a plasma clot. Lysis efficacy was measured as clot weight reduction. Cavitational mechanisms were investigated by monitoring subharmonic and broadband noise. In the absence of Optison, 1.7 MHz pulsed ultrasound with 1.5 MPa peak-negative pressure applied for 30 min resulted in 45 +/- 19% lysis enhancement relative to rt-PA alone. Cavitation was not detected, indicating a role of noncavitational effects of ultrasound. The addition of Optison increased lysis enhancement to 88 +/- 25%. Inertial cavitation was present only at the start of the exposure, while low-amplitude subharmonic emissions persisted throughout. Additional protocols suggested a possible correlation between the increased lysis in the presence of Optison and the subharmonic emission, indicating a potentially important role of stable rather than inertial cavitation in microbubble-enhanced ultrasound-accelerated rt-PA-mediated thrombolysis.

[1]  Lawrence A Crum,et al.  Inertial cavitation dose and hemolysis produced in vitro with or without Optison. , 2003, Ultrasound in medicine & biology.

[2]  C G Lauer,et al.  Effect of Ultrasound on Tissue‐Type Plasminogen Activator‐Induced Thrombolysis , 1992, Circulation.

[3]  K. Ohmori,et al.  Enhancement of ultrasound-accelerated thrombolysis by echo contrast agents: dependence on microbubble structure. , 1999, Ultrasound in medicine & biology.

[4]  K. Tachibana,et al.  Albumin microbubble echo-contrast material as an enhancer for ultrasound accelerated thrombolysis. , 1995, Circulation.

[5]  C. Francis,et al.  Cavitational mechanisms in ultrasound-accelerated thrombolysis at 1 MHz. , 2000, Ultrasound in medicine & biology.

[6]  Xinmai Yang,et al.  A model for the dynamics of gas bubbles in soft tissue. , 2005, The Journal of the Acoustical Society of America.

[7]  C. Francis,et al.  Ultrasound enhancement of thrombolysis and reperfusion in vitro. , 1993, Journal of the American College of Cardiology.

[8]  C. Francis,et al.  Ultrasound enhancement of rabbit femoral artery thrombolysis. , 1997, Cardiovascular surgery.

[9]  M. Carr,et al.  Fibrin has larger pores when formed in the presence of erythrocytes. , 1987, The American journal of physiology.

[10]  Z. Vered,et al.  Does external ultrasound accelerate thrombolysis? Results from a rabbit model. , 1994, Circulation.

[11]  Timothy G. Leighton,et al.  High‐resolution bubble sizing through detection of the subharmonic response with a two‐frequency excitation technique , 1996 .

[12]  A. Soltani The Safety of Using High Frequency, Low Intensity Ultrasound to Enhance Thrombolysis , 2006 .

[13]  P. Roberson,et al.  Intracranial Clot Lysis With Intravenous Microbubbles and Transcranial Ultrasound in Swine , 2004, Stroke.

[14]  Sheila Podell,et al.  Physical and biochemical stability of Optison®, an injectable ultrasound contrast agent , 1999, Biotechnology and applied biochemistry.

[15]  Anthony I. Eller,et al.  Generation of Subharmonics of Order One‐Half by Bubbles in a Sound Field , 1968 .

[16]  C. Francis,et al.  Acceleration of fibrinolysis by ultrasound in a rabbit ear model of small vessel injury. , 1994, Thrombosis research.

[17]  P. T. Onundarson,et al.  Enhancement of fibrinolysis in vitro by ultrasound. , 1992, The Journal of clinical investigation.

[18]  Y Wu,et al.  Binding and lysing of blood clots using MRX-408. , 1998, Investigative radiology.

[19]  V. Larrue,et al.  High Rate of Recanalization of Middle Cerebral Artery Occlusion During 2-MHz Transcranial Color-Coded Doppler Continuous Monitoring Without Thrombolytic Drug , 2002, Stroke.

[20]  R. Apfel,et al.  In vitro measurements of inertial cavitation thresholds in human blood. , 1996, Ultrasound in medicine & biology.

[21]  Saurabh Datta,et al.  Correlation of cavitation with ultrasound enhancement of thrombolysis. , 2006, Ultrasound in medicine & biology.

[22]  R. Shlansky-Goldberg,et al.  Catheter-delivered ultrasound potentiates in vitro thrombolysis. , 1996, Journal of vascular and interventional radiology : JVIR.

[23]  K. Tachibana,et al.  Prototype therapeutic ultrasound emitting catheter for accelerating thrombolysis. , 1997, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[24]  P. Roberson,et al.  Microbubble potentiated ultrasound as a method of stroke therapy in a pig model: preliminary findings. , 2003, Journal of vascular and interventional radiology : JVIR.

[25]  C. Francis,et al.  Characterization of ultrasound-potentiated fibrinolysis in vitro , 1993 .

[26]  C. Francis,et al.  Ultrasound accelerates transport of recombinant tissue plasminogen activator into clots. , 1995, Ultrasound in medicine & biology.

[27]  T. Leighton The Acoustic Bubble , 1994 .

[28]  V. Larrue,et al.  Enhancement of enzymatic fibrinolysis with 2‐MHz ultrasound and microbubbles , 2004, Journal of thrombosis and haemostasis : JTH.

[29]  Werner Lauterborn,et al.  Numerical investigation of nonlinear oscillations of gas bubbles in liquids , 1976 .