Voltage control using eigen value decomposition of fast decoupled load flow Jacobian

Voltage deviations occur frequently in power systems. If the violation at some buses falls outside the prescribed range, it will be necessary to correct the problem by controlling reactive power resources. In this paper, an optimal algorithm is proposed to solve this problem by identifying the voltage buses, that will have a maximum effect on the affected buses, and setting their new set-points. This algorithm is based on the Eigen-Value Decomposition of the fast decoupled load flow Jacobian matrix. Different Case studies including IEEE 9, 14, 30 and 57 bus systems have been used to verify the method.

[1]  Amir Ameli,et al.  Multi-objective DG planning considering operational and economic viewpoints , 2013, 2013 13th International Conference on Environment and Electrical Engineering (EEEIC).

[2]  J. P. Paul,et al.  Improvements of the Secondary Voltage Control in France , 1987 .

[3]  Eduard Muljadi,et al.  Voltage regulation using a permanent magnet synchronous condenser with a series compensator , 2015, 2015 IEEE Energy Conversion Congress and Exposition (ECCE).

[4]  A. Rezaee Jordehi,et al.  Particle swarm optimisation (PSO) for allocation of FACTS devices in electric transmission systems: A review , 2015 .

[5]  Antonio Zecchino,et al.  Voltage control for unbalanced low voltage grids using a decoupled-phase on-load tap-changer transformer and photovoltaic inverters , 2015, 2015 50th International Universities Power Engineering Conference (UPEC).

[6]  Parviz Famouri,et al.  Assessment of Automatic Generation Control performance index criteria , 2014, 2014 IEEE PES T&D Conference and Exposition.

[7]  R. Feuillet,et al.  Immune-based selection of pilot nodes for secondary voltage control , 2010 .

[8]  J. Thorp,et al.  Optimal secondary voltage-VAR control using pilot point information structure , 1984, The 23rd IEEE Conference on Decision and Control.

[9]  G. Joos,et al.  A Secondary Voltage Control Strategy for Transmission Level Interconnection of Wind Generation , 2008, IEEE Transactions on Power Electronics.

[10]  Hamid Vakilzadian,et al.  The investigation of dielectric barrier impact on the breakdown voltage in high voltage systems by modeling and simulation , 2015, 2015 IEEE Power & Energy Society General Meeting.

[11]  Robert A. Schlueter,et al.  Methods for determining proximity to voltage collapse , 1991 .

[12]  Sukumar Kamalasadan,et al.  Hybrid Transient Energy Function-Based Real-Time Optimal Wide-Area Damping Controller , 2017, IEEE Transactions on Industry Applications.

[13]  Luis F. Ochoa,et al.  Voltage Control of PV-Rich LV Networks: OLTC-Fitted Transformer and Capacitor Banks , 2016, IEEE Transactions on Power Systems.

[14]  C. Aumuller,et al.  Determination of Power System Coherent Bus Groups by Novel Sensitivity-Based Method for Voltage Stability Assessment , 2002, IEEE Power Engineering Review.

[15]  Antonio J. Conejo,et al.  Secondary voltage control: nonlinear selection of pilot buses, design of an optimal control law, and simulation results , 1998 .

[16]  Alireza Khayatian,et al.  Performance Recovery of Voltage Source Converters With Application to Grid-Connected Fuel Cell DGs , 2018, IEEE Transactions on Smart Grid.

[17]  J.I. de la Fuente,et al.  Comparison of alternative algorithms to select pilot buses for secondary voltage control in electric power networks , 1994, Proceedings of MELECON '94. Mediterranean Electrotechnical Conference.

[18]  Ali Feliachi,et al.  Optimal voltage control using singular value decomposition of fast decoupled load flow jacobian , 2017, 2017 North American Power Symposium (NAPS).

[19]  Leon R. Roose,et al.  Energy management at the distribution grid using a Battery Energy Storage System (BESS) , 2016 .

[20]  Alireza Soroudi,et al.  Probabilistic determination of pilot points for zonal voltage control , 2012 .

[21]  Robert Broadwater,et al.  Application of Distributed Series Reactors in relieving congestion costs , 2016, 2016 IEEE/PES Transmission and Distribution Conference and Exposition (T&D).

[22]  Mohammad Reza Khalghani,et al.  Modifying Power Quality's Indices of Load by Presenting an Adaptive Method based on Hebb Learning Algorithm for Controlling DVR , 2014 .

[23]  B. Vahidi,et al.  Smart control mode selection for proper operation of synchronous distributed generators , 2012, Iranian Conference on Smart Grids.

[24]  Heidar Ali Shayanfar,et al.  Locating series FACTS devices for multi-objective congestion management improving voltage and transient stability , 2014, Eur. J. Oper. Res..

[25]  Shubhrata Gupta,et al.  UPFC facts devices in power system to improve the voltage profile and enhancement of power transfer loadability , 2016, 2016 IEEE 1st International Conference on Power Electronics, Intelligent Control and Energy Systems (ICPEICES).

[26]  G. Sasank Das,et al.  Optimal Allocation of FACTS Device with Multiple Objectives Using Genetic Algorithm , 2014 .

[27]  Ricardo B. Prada,et al.  Identifying Voltage Control Areas Based on the Interdependence of Control Equipment , 2013, Eurocon 2013.

[28]  Tamer Rousan,et al.  Selecting and Redesigning Distribution Feeders for CVR Benefits , 2016 .

[29]  R D Zimmerman,et al.  MATPOWER: Steady-State Operations, Planning, and Analysis Tools for Power Systems Research and Education , 2011, IEEE Transactions on Power Systems.

[30]  Reza Ghorbani,et al.  Optimal placement and sizing of the storage supporting transmission and distribution networks , 2016 .

[31]  Mohammad Reza Khalghani,et al.  Dynamic voltage restorer control using bi-objective optimisation to improve power quality's indices , 2014 .

[32]  Paula O. La Gatta,et al.  Comparison among methodologies for identification of pilot buses and its impact on the steady state secondary voltage control , 2014, 2014 11th IEEE/IAS International Conference on Industry Applications.

[33]  Mohammad Reza Khalghani,et al.  A novel self-tuning control method based on regulated bi-objective emotional learning controller's structure with TLBO algorithm to control DVR compensator , 2014, Appl. Soft Comput..

[34]  Philip C. Taylor,et al.  Zoning Evaluation for Improved Coordinated Automatic Voltage Control , 2015, IEEE Transactions on Power Systems.

[35]  R. Ghorbani,et al.  A nascent market for contingency reserve services using demand response , 2016 .