Insertion of electrode array using percutaneous cochlear implantation technique: a cadaveric study

Cochlear implantation is a surgical procedure for treating patients with hearing loss in which an electrode array is inserted into the cochlea. The traditional surgical approach requires drilling away a large portion of the bone behind the ear to provide anatomical reference and access to the cochlea. A minimally-invasive technique, called percutaneous cochlear implantation (PCI), has been proposed that involves drilling a linear path from the lateral skull to the cochlea avoiding vital structures and inserting the implant using that drilled path. The steps required to achieve PCI safely include: placing three bone-implanted markers surrounding the ear, obtaining a CT scan, planning a surgical path to the cochlea avoiding vital anatomy, designing and constructing a microstereotactic frame that mounts on the markers and constrains the drill to the planned path, affixing the frame on the markers, using it to drill to the cochlea, and inserting the electrode through the drilled path. We present in this paper a cadaveric study demonstrating the PCI technique on three temporal bone cadaveric specimens for inserting electrode array into the cochlea. A custom fixture, called a Microtable, which is a type of microstereotactic frame that can be constructed in less than five minutes, was fabricated for each specimen and used to reach the cochlea. The insertion was successfully performed on all three specimens. Postinsertion CT scans confirm the correct placement of the electrodes inside the cochlea without any damage to the facial nerve.

[1]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[2]  M S Marion,et al.  Anatomical measurements of the cochlear aqueduct, round window membrane, round window niche, and facial recess. , 1982, The Laryngoscope.

[3]  Benoit M Dawant,et al.  Automatic segmentation of the facial nerve and chorda tympani in CT images using spatially dependent feature values. , 2008, Medical physics.

[4]  W. House Surgical considerations in cochlear implantation. , 1982, The Annals of otology, rhinology & laryngology. Supplement.

[5]  Guy Marchal,et al.  Multi-modality image registration by maximization of mutual information , 1996, Proceedings of the Workshop on Mathematical Methods in Biomedical Image Analysis.

[6]  Christoph Arnoldner,et al.  Surgical considerations in cochlear implantation in children and adults: A review of 342 cases in Vienna , 2005, Acta oto-laryngologica.

[7]  Omid Majdani,et al.  Clinical Validation Study of Percutaneous Cochlear Access Using Patient-Customized Microstereotactic Frames , 2010, Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology.

[8]  Jay B. West,et al.  The distribution of target registration error in rigid-body point-based registration , 2001, IEEE Transactions on Medical Imaging.

[9]  R. Balachandran,et al.  Percutaneous cochlear implant drilling via customized frames: An in vitro study , 2010, Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery.

[10]  Benoit M. Dawant,et al.  Determination of drill paths for percutaneous cochlear access accounting for target positioning error , 2007, SPIE Medical Imaging.

[11]  Benoit M. Dawant,et al.  Accuracy Evaluation of microTargeting Platforms for Deep-Brain Stimulation Using Virtual Targets , 2009, IEEE Transactions on Biomedical Engineering.

[12]  Omid Majdani,et al.  Time of cochlear implant surgery in academic settings , 2010, Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery.

[13]  D. Caleb Rucker,et al.  A MANUAL INSERTION MECHANISM FOR PERCUTANEOUS COCHLEAR IMPLANTATION , 2010 .

[14]  P. L. Le Roux,et al.  The Use of a Portable Head CT Scanner in the Intensive Care Unit , 2010, The Journal of neuroscience nursing : journal of the American Association of Neuroscience Nurses.

[15]  Omid Majdani,et al.  Clinical Validation of Percutaneous Cochlear Implant Surgery: Initial Report , 2008, The Laryngoscope.

[16]  House Wf Surgical considerations in cochlear implantation. , 1982 .

[17]  Benoit M Dawant,et al.  Automatic Identification and 3D Rendering of Temporal Bone Anatomy , 2009, Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology.

[18]  Guy Marchal,et al.  Multimodality image registration by maximization of mutual information , 1997, IEEE Transactions on Medical Imaging.

[19]  J. Michael Fitzpatrick,et al.  Customized, rapid-production microstereotactic table for surgical targeting: description of concept and in vitro validation , 2009, International Journal of Computer Assisted Radiology and Surgery.