Proposed Mathematical Model for Calibration of Potential Detection of Nonlinear Responses in Biological Media Exposed to RF Energy

─ An efficient way to test for potential unsymmetrical nonlinear responses in biological tissue samples exposed to a microwave signal is to observe the second harmonic in a cavity resonant at the two frequencies, with collocated antinodes. Such a response would be of interest as being a mechanism that could enable demodulation of information-carrying waveforms. In this work, an electric circuit model is proposed to facilitate calibration of any putative nonlinear RF energy conversion inside a high quality-factor resonant cavity with a known nonlinear loading device. The first and second harmonic responses of the cavity due to loading with the nonlinear and lossy material are also demonstrated. The results from the proposed mathematical model give a good indication of the input power required to detect any very weak second harmonic signal in relation to the sensitivity of the measurement equipment. Hence, this proposed mathematical model will assist in determining the level of the second harmonic signal in the detector as a function of the specific input power applied. Index Terms ─ Biological responses, nonlinearity, quality factor, resonant cavity, second harmonic.

[1]  RF nonlinear interactions in living cells–II: Detection methods for spectral signatures , 2003, Bioelectromagnetics.

[2]  Q. Balzano,et al.  RF nonlinear interactions in living cells–I: Nonequilibrium thermodynamic theory , 2003, Bioelectromagnetics.

[3]  S. Lalléchère,et al.  Stochastic Sensitivity in Homogeneous Electromagnetic-Thermal Dosimetry Model of Human Brain , 2016 .

[4]  S. Pisa,et al.  Interaction between 3-T MRI systems and patients with an implanted pacemaker , 2015 .

[5]  R. A. Abd-Alhameed,et al.  The Design of a Resistively Loaded Bowtie Antenna for Applications in Breast Cancer Detection Systems , 2012, IEEE Transactions on Antennas and Propagation.

[6]  R.A. Abd-Alhameed,et al.  Computation of Electromagnetic Fields in Assemblages of Biological Cells Using a Modified Finite-Difference Time-Domain Scheme , 2007, IEEE Transactions on Microwave Theory and Techniques.

[7]  Quirino Balzano,et al.  Absence of nonlinear responses in cells and tissues exposed to RF energy at mobile phone frequencies using a doubly resonant cavity , 2010, Bioelectromagnetics.

[8]  Quirino Balzano Proposed test for detection of nonlinear responses in biological preparations exposed to RF energy. , 2002, Bioelectromagnetics.

[9]  Peter S. Excell,et al.  Microscopic biological cell level model using modified finite-difference time-domain at mobile radio frequences , 2008 .

[10]  M. Goni Electric Field Distribution in a Biological Cell for Various Electrode Configurations-A Simulation Study , 2012 .

[11]  Chan H. See,et al.  Mathematical model for calibration of nonlinear responses in biological media exposed to RF energy , 2014 .

[12]  A.A. Rezazadeh,et al.  High tangential signal sensitivity GaAs planar doped barrier diodes for microwave/millimeter-wave power detector applications , 2005, IEEE Microwave and Wireless Components Letters.

[13]  Mohammad Tariqul Islam,et al.  Evaluation of em absorption in human head with metamaterial attachment , 2010 .

[14]  Raed A. Abd-Alhameed,et al.  HYBRID COMPUTATIONAL SCHEME FOR ANTENNA- HUMAN BODY INTERACTION , 2013 .

[15]  Abdullah Ferikoglu,et al.  Electromagnetic Absorption Rate in a Multilayer Human Tissue Model Exposed to Base-Station Radiation Using Transmission Line Analysis , 2014, IEEE Antennas and Wireless Propagation Letters.

[16]  H. Acikgoz Internal Homogenization of Biological Tissues for Electromagnetic Dosimetry , 2016 .

[17]  L. Challis,et al.  Mechanisms for interaction between RF fields and biological tissue , 2005, Bioelectromagnetics.