Full scale field study of sound transmission across plenum windows

A full scale field measurement of the acoustical insertion loss of plenum windows was carried out in the present investigation. Two identical mock-up test rooms with dimensions the same as those commonly adopted for Hong Kong public housing were built side-by-side next to a busy trunk road. One of them was equipped with plenum windows, while the other with the conventional side-hung casement windows. Four internal room settings were included in this study. Results show that both the room modes and the acoustic modes within the plenum window cavities were affecting significantly the low frequency sound transmission. After correcting for the indoor reverberation/absorption effect, the acoustical benefit achieved by replacing side-hung casement windows with the plenum windows tested in the present study was between 7.1 and 9.5 dBA. By comparing the average equivalent sound pressure levels inside the two test rooms with the traffic noise weighted acoustical benefit, it was found that the changes of receiver room reverberation and acoustic modal effects due to such replacement would result in a reduction of plenum window sound insulation performance by 0.2–1.5 dBA. The insulation is stronger for larger room size with stronger indoor sound absorption.

[1]  Carl Hopkins,et al.  ISO 16283-1 Acoustics - Field measurement of sound insulation in buildings and of building elements - Airborne sound insulation , 2014 .

[2]  P. Jean Sound transmission through opened windows , 2009 .

[3]  A. Muzet Environmental noise, sleep and health. , 2007, Sleep medicine reviews.

[4]  Cinzia Buratti,et al.  Indoor noise reduction index with open window , 2002 .

[5]  A. Gidlöf-Gunnarsson,et al.  Effects of road traffic noise and the benefit of access to quietness , 2006 .

[6]  Lawrence E. Kinsler,et al.  Fundamentals of acoustics , 1950 .

[7]  R. J. Wells Acoustical Plenum Chambers , 1957 .

[8]  B. Berglund,et al.  Guidelines for community noise , 1999 .

[9]  X. Qiu,et al.  Different sound decay patterns and energy feedback in coupled volumes. , 2011, The Journal of the Acoustical Society of America.

[10]  Garai,et al.  European methodology for testing the airborne sound insulation characteristics of noise barriers in situ: experimental verification and comparison with laboratory data , 2000, The Journal of the Acoustical Society of America.

[11]  Howard C. Hardy,et al.  Noise Reduction of Folding Partitions , 1958 .

[12]  Jian Kang,et al.  Feasibility of applying micro-perforated absorbers in acoustic window systems , 2005 .

[13]  R. D. Ford,et al.  The sound insulation of partially open double glazing , 1973 .

[14]  António Tadeu,et al.  Sound transmission through single, double and triple glazing. Experimental evaluation , 2001 .

[15]  W. E. Scholes TRAFFIC NOISE CRITERIA , 1970 .

[16]  S K Tang,et al.  Plenum window insertion loss in the presence of a line source--a scale model study. , 2013, The Journal of the Acoustical Society of America.

[17]  Ulrich J. Kurze,et al.  Noise reduction by barriers , 1973 .

[18]  G. R. Watts Acoustic performance of parallel traffic noise barriers , 1996 .