A Wind Tunnel Study of Gaseous Pollutants in City Street Canyons
暂无分享,去创建一个
Steady state mean concentrations of tracer gas were measured in a 400:1 scale model of an idealized city with variable geometry placed within a wind tunnel at various orientations to the mean flow for a free stream velocity of 6.8 ft/sec. The tracer gas was released from two parallel line sources to simulate lanes of traffic in an effort to quantify the persistence of pollution as well as the mean values realized at street levels. An aerodynamically rough turbulent boundary layer of neutral thermal stratification was employed to simulate the atmosphere. Values of concentration measured in the model city were converted to prototype concentrations in ppm and compared to National Ambient Air Quality Standards. It was shown that single isolated structures may cause favorable mixing of pollution downwind but very high concentrations exist in the immediate leeward vicinity of the building. Two favorable geometries for city blocks tested were found to reduce pedestrian exposure to pollution both near heavy traff...