An approach to regulating the DC-link voltage of a voltage-source BTB system during power line faults

A voltage-source back-to-back system for the purpose of achieving power flow control and/or line-frequency change in transmission systems has the attractive features of reliable and continuous operation, even during power line faults. However, an overvoltage appearing across the dc link during the faults should be limited to as low a value as possible because it does affect the power device ratings. This paper proposes a dc-link voltage regulator for effectively suppressing the overvoltage during power line faults. This regulator is characterized by compensating for a time delay inherent in each current controller, and for a power flow imbalance occurring during power line faults. The validity of the proposed regulator is confirmed by theory and computer simulation.

[1]  A. Ekstrom,et al.  Multiterminal HVDC systems in urban areas of large cities , 1998 .

[2]  S. Halen,et al.  High-frequency impacts in a converter-based back-to-back tie; the Eagle Pass installation , 2003 .

[3]  S. Sugimoto,et al.  Development of a control system for a high-performance self-commutated AC/DC converter , 1998 .

[4]  G. Asplund Application of HVDC Light to power system enhancement , 2000, 2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077).

[5]  Hirofumi Akagi,et al.  Instantaneous Reactive Power Compensators Comprising Switching Devices without Energy Storage Components , 1984, IEEE Transactions on Industry Applications.

[6]  Boon-Teck Ooi,et al.  Force commutated HVDC and SVC based on phase-shifted multi-converter modules , 1993 .

[7]  S. Sugimoto,et al.  Development and testing of prototype models for a high-performance 300 MW self-commutated AC/DC converter , 1997 .

[8]  M. Noroozian,et al.  The Potential Use of Voltage-Sourced Converter-Based Back-to-Back Tie in Load Restorations , 2002, IEEE Power Engineering Review.

[9]  Yoshinao Matsushita,et al.  Prototype test of STATCOM and BTB based on voltage source converter using GCT thyristor , 2002, IEEE/PES Transmission and Distribution Conference and Exhibition.

[10]  Shigeru Tanaka,et al.  A Novel Control of Self-Commutated Converters for Large Power Applications , 1998 .

[11]  Makoto Hagiwara,et al.  Performance of a self-commutated BTB HVDC link system under a single-line-to-ground fault condition , 2003 .

[12]  Hirofumi Akagi,et al.  Analysis and design of a DC voltage-controlled static VAr compensator using quad-series voltage-source inverters , 1996 .