All Warm Compresses Are Not Equally Efficacious

Purpose To investigate which warm compress (WC) methods used in a small case series are the most effective in providing heat to the inner eyelids for the supplemental treatment of meibomian gland dysfunction. Methods Inclusion criteria included the following: 18 years or older and willingness to participate in the study, no current ocular inflammation/disease, and no ocular surgery within the last 6 months. Five patients were fully consented and enrolled. Various forms of contact and noncontact WC heating methods (dry, wet/moist, and chemically activated dry heat) were tested. A paired contralateral design was used; each subject had a heated test eye and an unheated control eye. For both test and control eyes, the temperature of the external upper, external lower, and internal lower lids was measured at baseline and every 2 minutes for 10 minutes during application. Each participant underwent each of the eight treatments under study. Microwaved compresses were heated to 47 ± 1.0°C; two compresses were self-heating and thus not under investigator control. Results The mean (±SD) age of the patients was 42.2 (±20.3) years. Out of the eight methods tested, the bundled wet/moist towel method was the only compress that elevated the temperature of all three lid surfaces (external upper, external lower, and internal lower lids) to 40°C or higher. The chemically activated EyeGiene, MGDRx EyeBag, and MediBeads compresses resulted in the lowest temperature increase at the inner palpebral surface. Conclusions The Bundle method, although the most labor intensive, increased lid temperatures above therapeutic levels, as reported in the literature, for all measured sections during the WC application. As such, this method of WC application can be recommended for supplemental at-home therapy for meibomian gland dysfunction and any condition requiring that therapeutic heat of 40°C be administered to the meibomian glands.

[1]  S. Schrader,et al.  Six-Month Effects of a Thermodynamic Treatment for MGD and Implications of Meibomian Gland Atrophy , 2014, Cornea.

[2]  N. Morishige,et al.  Comparison of effect of five warming devices onto tear functions, meibomian glands and ocular surface , 2014 .

[3]  S. Schrader,et al.  Evaluation of an automated thermodynamic treatment (LipiFlow®) system for meibomian gland dysfunction: a prospective, randomized, observer-masked trial. , 2014, The ocular surface.

[4]  J. Wolffsohn,et al.  Effect of a Commercially Available Warm Compress on Eyelid Temperature and Tear Film in Healthy Eyes , 2013, Optometry and vision science : official publication of the American Academy of Optometry.

[5]  S. Kim,et al.  A randomised controlled trial comparing a thermal massager with artificial teardrops for the treatment of dry eye , 2013, British Journal of Ophthalmology.

[6]  D. Korb,et al.  Warm Compresses and the Risks of Elevated Corneal Temperature With Massage , 2013, Cornea.

[7]  D. Korb,et al.  The role of heat in rubbing and massage-related corneal deformation. , 2012, Contact lens & anterior eye : the journal of the British Contact Lens Association.

[8]  K. Tsubota,et al.  The international workshop on meibomian gland dysfunction: executive summary. , 2011, Investigative ophthalmology & visual science.

[9]  K. Tsubota,et al.  The international workshop on meibomian gland dysfunction: report of the subcommittee on management and treatment of meibomian gland dysfunction. , 2011, Investigative ophthalmology & visual science.

[10]  Louis Tong,et al.  The international workshop on meibomian gland dysfunction: report of the subcommittee on the epidemiology of, and associated risk factors for, MGD. , 2011, Investigative ophthalmology & visual science.

[11]  R. Bedi,et al.  Nonobvious Obstructive Meibomian Gland Dysfunction , 2010, Cornea.

[12]  D. Korb,et al.  Inner Eyelid Surface Temperature as a Function of Warm Compress Methodology , 2008, Optometry and vision science : official publication of the American Academy of Optometry.

[13]  Ingvar Holmér,et al.  Dry and Wet Heat Transfer Through Clothing Dependent on the Clothing Properties Under Cold Conditions , 2008, International journal of occupational safety and ergonomics : JOSE.

[14]  D. Korb,et al.  Warm Compress Induced Visual Degradation and Fischer-Schweitzer Polygonal Reflex , 2007, Optometry and vision science : official publication of the American Academy of Optometry.

[15]  Carolyn G. Begley,et al.  The epidemiology of dry eye disease: report of the Epidemiology Subcommittee of the International Dry Eye WorkShop (2007). , 2007, The ocular surface.

[16]  A. Lam,et al.  Effect of Warm Compress Therapy From Hard-Boiled Eggs on Corneal Shape , 2007, Cornea.

[17]  R. Lee,et al.  The relative thermal stability of tissue macromolecules and cellular structure in burn injury. , 2005, Burns : journal of the International Society for Burn Injuries.

[18]  A. Bron,et al.  The contribution of meibomian disease to dry eye. , 2004, The ocular surface.

[19]  Elizabeth M. Crown,et al.  Moisture Effects in Heat Transfer Through Clothing Systems for Wildland Firefighters , 2004, International journal of occupational safety and ergonomics : JOSE.

[20]  D. Korb,et al.  Increase in Tear Film Lipid Layer Thickness Following Treatment with Warm Compresses in Patients with Meibomian Gland Dysfunction , 2003, Eye & contact lens.

[21]  K. Tsubota,et al.  Treatment of non-inflamed obstructive meibomian gland dysfunction by an infrared warm compression device , 2002, British Journal of Ophthalmology.

[22]  K. Tsubota,et al.  Improvement of tear stability following warm compression in patients with meibomian gland dysfunction. , 2000, Advances in experimental medicine and biology.

[23]  Clive G. Wilson,et al.  Effect of an oil and water emulsion on tear evaporation rate. , 2000, Advances in experimental medicine and biology.

[24]  D R Korb,et al.  Tear Film Lipid Layer Thickness as a Function of Blinking , 1994, Cornea.

[25]  J. Larke,et al.  Meibomian gland dysfunction: some clinical, biochemical and physical observations , 1990, Ophthalmic & physiological optics.

[26]  G. Bohigian External eye — Methods of examination , 1975 .

[27]  N. Schweitzer A fluorescein colored polygonal pattern in the human cornea. The reflectographic "Furchenbild" of Fischer. , 1967, Archives of ophthalmology.