Pulse-clamp technique for single neuron stimulation electrode characterization

Miniaturized electrodes, structures and devices are necessary to achieve high target selectivity during stimulation in single neuron networks, while significant charge transfer is still demanded. A reliable test method is required to evaluate charge injection capability for high resolution neural stimulation applications that demand both a large amount of charge injection and a small electrode size. A circuit designed for the pulse-clamp technique was employed to characterize the electrode charge-storage capability of microelectrodes of sizes smaller than 300 µm in diameter. The circuit allows different electrodes and surface modifications to be quickly and accurately compared. Pulse-clamp measurements are performed on planar microelectrodes in 154 mM phosphate buffered saline (PBS) solution with 400 µs long pulses at charges up to 40 nC. The pulse-clamp and cyclic voltammetry results of sputtered iridium oxide film (SIROF) electrodes of different sizes show charge losses of less than 3% and a superior reversible charge injection capability compared to platinum microelectrodes of the same size, even at higher charge density levels.

[1]  J. Randles Kinetics of rapid electrode reactions , 1947 .

[2]  T Stieglitz,et al.  Characterization and optimization of microelectrode arrays for in vivo nerve signal recording and stimulation. , 1997, Biosensors & bioelectronics.

[3]  W. Cascio,et al.  Electrodeposited iridium oxide pH electrode for measurement of extracellular myocardial acidosis during acute ischemia. , 1998, Analytical chemistry.

[4]  T.L. Rose,et al.  Electrical stimulation with Pt electrodes. VIII. Electrochemically safe charge injection limits with 0.2 ms pulses (neuronal application) , 1990, IEEE Transactions on Biomedical Engineering.

[5]  Robert J. Greenberg,et al.  Pulse-Clamp Technique for Characterizing Neural-Stimulating Electrodes , 2007 .

[6]  J M Marston,et al.  Electrical stimulation with pt electrodes. IV. Factors influencing Pt dissolution in inorganic saline. , 1980, Biomaterials.

[7]  U. Schnakenberg,et al.  Evaluation of SIROF Microelectrodes for Single Neuron Stimulation in Biohybrid Circuits , 2007, TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference.

[8]  B. Conway,et al.  Surface and bulk processes at oxidized iridium electrodes—I. Monolayer stage and transition to reversible multilayer oxide film behaviour , 1983 .

[9]  Wilfried Mokwa,et al.  Sputtered Ir Films Evaluated for Electrochemical Performance I. Experimental Results , 2008 .

[10]  S.F. Cogan In vivo and In vitro Differences in the Charge-injection and Electrochemical Properties of Iridium Oxide Electrodes , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[11]  U. Schnakenberg,et al.  Sputtered Iridium Oxide Films as Charge Injection Material for Functional Electrostimulation , 2004 .

[12]  J. Thomas Mortimer,et al.  The Pulse‐Clamp Method for Analyzing the Electrochemistry on Neural Stimulating Electrodes , 1993 .