Top 10 Ways to Easily Identify Human Factors Engineering Hazards

Many hospitals and medical device manufacturers are making patient safety a top priority. When medical devices or software have poor usability, they represent latent failures, or accidents waiting to happen. Not only can these latent failures cause harm to the patient, they can also cause injury, unnecessary cognitive workload, and inefficiency for the healthcare worker. Human factors engineering (HFE) principles and methods can assist in finding and fixing these patient safety problems. However, often these methods require expertise in the discipline of HFE. We discuss here 10 simple ways that can be used by HFE novices and experts alike to identify HFE hazards that could otherwise be overlooked.

[1]  F. Simons,et al.  Hazards of unintentional injection of epinephrine from autoinjectors: a systematic review. , 2009, Annals of allergy, asthma & immunology : official publication of the American College of Allergy, Asthma, & Immunology.

[2]  Jiajie Zhang,et al.  Applying heuristic evaluation to improve the usability of a telemedicine system. , 2006, Telemedicine journal and e-health : the official journal of the American Telemedicine Association.

[3]  P Diggory,et al.  Comparison of elderly people's technique in using two dry powder inhalers to deliver zanamivir: randomised controlled trial , 2001, BMJ : British Medical Journal.

[4]  Randolph G. Bias,et al.  Cost-Justifying Usability: An Update for the Internet Age , 2005 .

[5]  Ashish Joshi,et al.  Usability of a Patient Education and Motivation Tool Using Heuristic Evaluation , 2009, Journal of medical Internet research.

[6]  Laura Lin Gosbee Nuts! I can't figure out how to use my life-saving epinephrine auto-injector! , 2004, Joint Commission journal on quality and safety.

[7]  Michael Wiklund,et al.  Designing Usability into Medical Products , 2004 .

[8]  Kim J. Vicente,et al.  Patient Safety, Potential Adverse Drug Events, and Medical Device Design: A Human Factors Engineering Approach , 2001, J. Biomed. Informatics.

[9]  A. D. Fisk,et al.  Analysis of a “Simple” Medical Device , 2001 .

[10]  Elizabeth Murphy,et al.  Medical device development: the challenge for ergonomics. , 2008, Applied ergonomics.

[11]  Welch Dl,et al.  Human factors in the health care facility. , 1998 .

[12]  J Gosbee,et al.  Human factors engineering design demonstrations can enlighten your RCA team , 2003, Quality & safety in health care.

[13]  Scott Draper,et al.  Using "no problem found" in infusion pump programing as a springboard for learnning about human factors engineering. , 2004, Joint Commission journal on quality and safety.

[14]  Vimla L. Patel,et al.  Heuristic evaluation of infusion pumps: implications for patient safety in Intensive Care Units , 2004, Int. J. Medical Informatics.

[15]  Elizabeth M Borycki,et al.  Using heuristic evaluations to assess the safety of health information systems. , 2009, Studies in health technology and informatics.

[16]  Philippe Jolliet,et al.  Evaluation of the user-friendliness of seven new generation intensive care ventilators , 2009, Intensive Care Medicine.