Assessment of physiological noise modelling methods for functional imaging of the spinal cord

The spinal cord is the main pathway for information between the central and the peripheral nervous systems. Non-invasive functional MRI offers the possibility of studying spinal cord function and central sensitisation processes. However, imaging neural activity in the spinal cord is more difficult than in the brain. A significant challenge when dealing with such data is the influence of physiological noise (primarily cardiac and respiratory), and currently there is no standard approach to account for these effects. We have previously studied the various sources of physiological noise for spinal cord fMRI at 1.5T and proposed a physiological noise model (PNM) (Brooks et al., 2008). An alternative de-noising strategy, selective averaging filter (SAF), was proposed by Deckers et al. (2006). In this study we reviewed and implemented published physiological noise correction methods at higher field (3T) and aimed to find the optimal models for gradient-echo-based BOLD acquisitions. Two general techniques were compared: physiological noise model (PNM) and selective averaging filter (SAF), along with regressors designed to account for specific signal compartments and physiological processes: cerebrospinal fluid (CSF), motion correction (MC) parameters, heart rate (HR), respiration volume per time (RVT), and the associated cardiac and respiratory response functions. Functional responses were recorded from the cervical spinal cord of 18 healthy subjects in response to noxious thermal and non-noxious punctate stimulation. The various combinations of models and regressors were compared in three ways: the model fit residuals, regression model F-tests and the number of activated voxels. The PNM was found to outperform SAF in all three tests. Furthermore, inclusion of the CSF regressor was crucial as it explained a significant amount of signal variance in the cord and increased the number of active cord voxels. Whilst HR, RVT and MC explained additional signal (noise) variance, they were also found (in particular HR and RVT) to have a negative impact on the parameter estimates (of interest)--as they may be correlated with task conditions e.g. noxious thermal stimuli. Convolution with previously published cardiac and respiratory impulse response functions was not found to be beneficial. The other novel aspect of current study is the investigation of the influence of pre-whitening together with PNM regressors on spinal fMRI data. Pre-whitening was found to reduce non-white noise, which was not accounted for by physiological noise correction, and decrease false positive detection rates.

[1]  S. Kollias,et al.  Duvernoy's Atlas of the Human Brain Stem and Cerebellum , 2009 .

[2]  Patrick W Stroman,et al.  Magnetic resonance imaging of neuronal function in the spinal cord: spinal FMRI. , 2005, Clinical medicine & research.

[3]  Arthur W. Toga,et al.  Automatic independent component labeling for artifact removal in fMRI , 2008, NeuroImage.

[4]  Peter A. Bandettini,et al.  Separating respiratory-variation-related fluctuations from neuronal-activity-related fluctuations in fMRI , 2006, NeuroImage.

[5]  Jeff H. Duyn,et al.  Low-frequency fluctuations in the cardiac rate as a source of variance in the resting-state fMRI BOLD signal , 2007, NeuroImage.

[6]  T E Lund,et al.  fcMRI—Mapping functional connectivity or correlating cardiac‐induced noise? , 2001, Magnetic resonance in medicine.

[7]  Karl J. Friston,et al.  Movement‐Related effects in fMRI time‐series , 1996, Magnetic resonance in medicine.

[8]  M. Filippi,et al.  Evidence for enhanced functional activity of cervical cord in relapsing multiple sclerosis , 2008, Magnetic resonance in medicine.

[9]  Peter A. Bandettini,et al.  Integration of motion correction and physiological noise regression in fMRI , 2008, NeuroImage.

[10]  T. Jaermann,et al.  A preliminary study of the effects of trigger timing on diffusion tensor imaging of the human spinal cord. , 2006, AJNR. American journal of neuroradiology.

[11]  U Klose,et al.  The Influence of Pulse and Respiration on Spinal Cerebrospinal Fluid Pulsation , 2004, Investigative radiology.

[12]  Patrick W. Stroman,et al.  Functional magnetic resonance imaging of the human spinal cord during vibration stimulation of different dermatomes , 2008, Neuroradiology.

[13]  J. Mazziotta,et al.  Brain Mapping: The Methods , 2002 .

[14]  William D. Willis,et al.  Sensory Mechanisms of the Spinal Cord , 1979, Springer US.

[15]  Jörn Diedrichsen,et al.  Advances in functional imaging of the human cerebellum. , 2010, Current opinion in neurology.

[16]  Y. Yen,et al.  False cerebral activation on BOLD functional MR images: study of low-amplitude motion weakly correlated to stimulus. , 2000, AJNR. American journal of neuroradiology.

[17]  Irene Tracey,et al.  Resting fluctuations in arterial carbon dioxide induce significant low frequency variations in BOLD signal , 2004, NeuroImage.

[18]  Catie Chang,et al.  Relationship between respiration, end-tidal CO2, and BOLD signals in resting-state fMRI , 2009, NeuroImage.

[19]  A. Dickenson,et al.  Spinal cord mechanisms of pain. , 2008, British journal of anaesthesia.

[20]  Michael Brady,et al.  Improved Optimization for the Robust and Accurate Linear Registration and Motion Correction of Brain Images , 2002, NeuroImage.

[21]  F. H. Lopes da Silva,et al.  A study of the brain's resting state based on alpha band power, heart rate and fMRI , 2008, NeuroImage.

[22]  Laurel O. Sillerud,et al.  Functional Magnetic Resonance Imaging of Motor Activation in the Human Cervical Spinal Cord , 1996, NeuroImage.

[23]  Andrew T. Smith,et al.  A comment on the severity of the effects of non-white noise in fMRI time-series , 2007, NeuroImage.

[24]  Kevin Murphy,et al.  Mapping the MRI voxel volume in which thermal noise matches physiological noise—Implications for fMRI , 2007, NeuroImage.

[25]  Mina Khosh Nejad,et al.  Characterization of cardiac-related noise in fMRI of the cervical spinal cord. , 2009, Magnetic resonance imaging.

[26]  P. Rainville,et al.  Establishing a link between heart rate and pain in healthy subjects: a gender effect. , 2005, The journal of pain : official journal of the American Pain Society.

[27]  Zhishun Wang,et al.  Visual inspection of independent components: Defining a procedure for artifact removal from fMRI data , 2010, Journal of Neuroscience Methods.

[28]  Thomas E. Nichols,et al.  Non-white noise in fMRI: Does modelling have an impact? , 2006, NeuroImage.

[29]  R. D'Mello,et al.  REVIEWARTICLES Spinal cord mechanisms of pain , 2008 .

[30]  R. Coghill,et al.  Spatial distribution of nociceptive processing in the rat spinal cord. , 1991, Journal of neurophysiology.

[31]  Lawrence L. Wald,et al.  Comparison of physiological noise at 1.5 T, 3 T and 7 T and optimization of fMRI acquisition parameters , 2005, NeuroImage.

[32]  P. Stroman,et al.  Investigation of human cervical and upper thoracic spinal cord motion: Implications for imaging spinal cord structure and function , 2007, Magnetic resonance in medicine.

[33]  Lawrence L. Wald,et al.  Physiological noise and signal-to-noise ratio in fMRI with multi-channel array coils , 2011, NeuroImage.

[34]  G. Glover,et al.  Physiological noise in oxygenation‐sensitive magnetic resonance imaging , 2001, Magnetic resonance in medicine.

[35]  Catie Chang,et al.  Effects of model-based physiological noise correction on default mode network anti-correlations and correlations , 2009, NeuroImage.

[36]  A. Anderson,et al.  Respiratory effects in human functional magnetic resonance imaging due to bulk susceptibility changes. , 2001, Physics in medicine and biology.

[37]  X Hu,et al.  Retrospective estimation and correction of physiological fluctuation in functional MRI , 1995, Magnetic resonance in medicine.

[38]  Tom Johnstone,et al.  Motion correction and the use of motion covariates in multiple‐subject fMRI analysis , 2006, Human brain mapping.

[39]  G. Glover,et al.  Respiration‐induced B0 fluctuations and their spatial distribution in the human brain at 7 Tesla , 2002, Magnetic resonance in medicine.

[40]  Patrick W. Stroman,et al.  Development and validation of retrospective spinal cord motion time-course estimates (RESPITE) for spin-echo spinal fMRI: Improved sensitivity and specificity by means of a motion-compensating general linear model analysis , 2008, NeuroImage.

[41]  M. Fukunaga,et al.  Sources of functional magnetic resonance imaging signal fluctuations in the human brain at rest: a 7 T study. , 2009, Magnetic resonance imaging.

[42]  Egill Rostrup,et al.  Motion or activity: their role in intra- and inter-subject variation in fMRI , 2005, NeuroImage.

[43]  O. Speck,et al.  Prospective Real-Time Slice-by-Slice Motion Correction for fMRI in Freely Moving Subjects , 2006, Magnetic Resonance Materials in Physics, Biology and Medicine.

[44]  Christian Büchel,et al.  Direct Evidence for Spinal Cord Involvement in Placebo Analgesia , 2009, Science.

[45]  Jeff H. Duyn,et al.  An adaptive filter for suppression of cardiac and respiratory noise in MRI time series data , 2006, NeuroImage.

[46]  P. Stroman,et al.  Discrimination of errors from neuronal activity in functional MRI of the human spinal cord by means of general linear model analysis , 2006, Magnetic resonance in medicine.

[47]  Giovanni Giulietti,et al.  Issues about the fMRI of the human spinal cord. , 2004, Magnetic resonance imaging.

[48]  G. Paxinos,et al.  The Spinal Cord: A Christopher and Dana Reeve Foundation Text and Atlas , 2009 .

[49]  Peter A. Bandettini,et al.  The respiration response function: The temporal dynamics of fMRI signal fluctuations related to changes in respiration , 2008, NeuroImage.

[50]  Walter H. Backes,et al.  Spinal cord functional MRI at 3 T: Gradient echo echo-planar imaging versus turbo spin echo , 2008, NeuroImage.

[51]  R Turner,et al.  Cortical and subcortical control of tongue movement in humans: a functional neuroimaging study using fMRI. , 1999, Journal of applied physiology.

[52]  Karl J. Friston,et al.  To Smooth or Not to Smooth? Bias and Efficiency in fMRI Time-Series Analysis , 2000, NeuroImage.

[53]  Stephen D. Mayhew,et al.  Determination of the human brainstem respiratory control network and its cortical connections in vivo using functional and structural imaging , 2009, NeuroImage.

[54]  Hang Joon Jo,et al.  Mapping sources of correlation in resting state FMRI, with artifact detection and removal , 2010, NeuroImage.

[55]  Ludovico Minati,et al.  Physiological recordings: Basic concepts and implementation during functional magnetic resonance imaging , 2009, NeuroImage.

[56]  Gian Domenico Iannetti,et al.  Behavioral/systems/cognitive Functional Responses in the Human Spinal Cord during Willed Motor Actions: Evidence for Side-and Rate-dependent Activity , 2022 .

[57]  Mark J Lowe,et al.  Cardiac-induced physiologic noise in tissue is a direct observation of cardiac-induced fluctuations. , 2004, Magnetic resonance imaging.

[58]  J. Haxby,et al.  Localization of Cardiac-Induced Signal Change in fMRI , 1999, NeuroImage.

[59]  Patrick W. Stroman,et al.  Spatial normalization, bulk motion correction and coregistration for functional magnetic resonance imaging of the human cervical spinal cord and brainstem. , 2008, Magnetic resonance imaging.

[60]  Julien Cohen-Adad,et al.  BOLD signal responses to controlled hypercapnia in human spinal cord , 2010, NeuroImage.

[61]  Fuqiang Zhao,et al.  BOLD and blood volume-weighted fMRI of rat lumbar spinal cord during non-noxious and noxious electrical hindpaw stimulation , 2008, NeuroImage.

[62]  Patrick W Stroman,et al.  Applying functional MRI to the spinal cord and brainstem. , 2010, Magnetic resonance imaging.

[63]  Patrick W Stroman,et al.  Spinal fMRI investigation of human spinal cord function over a range of innocuous thermal sensory stimuli and study-related emotional influences. , 2009, Magnetic resonance imaging.

[64]  Hugo D. Critchley,et al.  Following One's Heart: Cardiac Rhythms Gate Central Initiation of Sympathetic Reflexes , 2009, The Journal of Neuroscience.

[65]  Toshiki Endo,et al.  Blood Oxygenation Level-Dependent Visualization of Synaptic Relay Stations of Sensory Pathways along the Neuroaxis in Response to Graded Sensory Stimulation of a Limb , 2006, The Journal of Neuroscience.

[66]  Gian Domenico Iannetti,et al.  A quantitative comparison of BOLD fMRI responses to noxious and innocuous stimuli in the human spinal cord , 2010, NeuroImage.

[67]  Richard G. Wise,et al.  Physiological noise modelling for spinal functional magnetic resonance imaging studies , 2008, NeuroImage.

[68]  P W Stroman,et al.  Tactile Sensory and Pain Networks in the Human Spinal Cord and Brain Stem Mapped by Means of Functional MR Imaging , 2010, American Journal of Neuroradiology.

[69]  G H Glover,et al.  Image‐based method for retrospective correction of physiological motion effects in fMRI: RETROICOR , 2000, Magnetic resonance in medicine.

[70]  Stephen M. Smith,et al.  Temporal Autocorrelation in Univariate Linear Modeling of FMRI Data , 2001, NeuroImage.

[71]  B. Poncelet,et al.  Oscillatory motion of the normal cervical spinal cord. , 1994, Radiology.

[72]  Stephen D. Mayhew,et al.  Brainstem functional magnetic resonance imaging: Disentangling signal from physiological noise , 2008, Journal of magnetic resonance imaging : JMRI.

[73]  Oliver Speck,et al.  The impact of physiological noise correction on fMRI at 7 T , 2011, NeuroImage.

[74]  P. Bandettini,et al.  The effect of respiration variations on independent component analysis results of resting state functional connectivity , 2008, Human brain mapping.

[75]  Catie Chang,et al.  Influence of heart rate on the BOLD signal: The cardiac response function , 2009, NeuroImage.