Solid timber beams strengthened with steel plates – Experimental studies

Abstract This paper presents the results of tests carried out on solid timber beams made of new wood (NW) and old wood (OW), which were subjected to bending after they were strengthened with steel plates and an epoxy adhesive. The beam specimens tested varied in their strengthening configurations (including configurations applicable to heritage structures, which are acceptable from the conservation point of view). The results obtained when steel plates were used for strengthening were found to be comparable to those strengthened with FRP (fibre reinforced polymer) materials. The load-bearing capacity of the strengthened specimens increased by as much as 100% relative to that of unstrengthened reference specimens. The values of the load-bearing capacity of the wood–steel plate joint determined under tension and compression are also reported. The research shows convincingly the impact of moisture content of the wood on the load-bearing capacity of all glued joints. In all tested cases, the failure ran right through the wood. It should be noted also that sand blasting was used to ensure proper adhesion of steel plates to the wood.

[1]  Maria Rosa Valluzzi,et al.  Flexural strengthening of timber beams by traditional and innovative techniques , 2007 .

[2]  Maurizio Piazza,et al.  Restoration and Strengthening of Timber Structures: Principles, Criteria, and Examples , 2007 .

[3]  Felipe Hideyoshi Icimoto,et al.  Restoration of Structural Timber Elements Using Epoxy Resin: Analysis of Mechanical Properties , 2013 .

[4]  Jerzy Jasieńko Glue Joints Used For Reinforcing the Damaged Ends of Wooden Beams , 2001 .

[5]  A. Harte,et al.  Low-grade glued laminated timber reinforced with FRP plate , 2011 .

[6]  Abílio M. P. De Jesus,et al.  Analysis of solid wood beams strengthened with CFRP laminates of distinct lengths , 2012 .

[7]  H. J. Larsen,et al.  DS/ENV 1995-1-1 NAD National Application Document for Eurocode 5: Design of Timber Structures, Part 1-1: General Rules and Rules for Buildings , 1994 .

[8]  Benedetto Pizzo,et al.  Evaluation of a design approach to the on-site structural repair of decayed old timber end beams , 2013 .

[9]  D. Van Gemert,et al.  Structural restoration of wooden beams by means of epoxy resin , 1987 .

[10]  João Negrão,et al.  Bending Strength of Timber Beams Rehabilitated with Reinforced Epoxy Mortar Plates , 2008 .

[11]  L. Jankowski,et al.  Application of photoelastic coating technique in tests of solid wooden beams reinforced with CFRP strips , 2010 .

[12]  Anders Carolin,et al.  Carbon Fibre Reinforced Polymers for Strengthening of Structural Elements , 2003 .

[13]  Antonio Borri,et al.  Reinforcement of wood with natural fibers , 2013 .

[14]  M. Corradi,et al.  A method for flexural reinforcement of old wood beams with CFRP materials , 2005 .

[15]  R. Richard Avent,et al.  Factors Affecting Strength of Epoxy-Repaired Timber , 1986 .

[16]  Pilar de la Rosa García,et al.  Bending reinforcement of timber beams with composite carbon fiber and basalt fiber materials , 2013 .

[17]  Helena Cruz,et al.  Adhesives for On-Site Rehabilitation of Timber Structures , 2010 .

[18]  Jerzy Jasieńko,et al.  Experimental assessment of CFRP reinforced wooden beams by 4-point bending tests and photoelastic coating technique , 2009 .

[19]  Jerzy Jasieńko,et al.  Experimental tests and numerical analysis of historic bent timber elements reinforced with CFRP strips , 2013 .

[20]  João Custódio,et al.  Rehabilitation of timber structures – Preparation and environmental service condition effects on the bulk performance of epoxy adhesives , 2011 .

[21]  Annette M. Harte,et al.  Bonding of FRP materials to wood using thin epoxy gluelines , 2009 .

[22]  R. Luciano,et al.  Experimental investigation on flexural behavior of timber beams repaired with CFRP plates , 2014 .

[23]  L. Bednarz,et al.  Reinforcement of bent timber beams in historic buildings , 2009 .

[24]  G. F. Loedolff,et al.  Laminated Wood Beams Reinforced with Steel Strips , 1968 .

[25]  M. Corradi,et al.  Strengthening of timber beams with high strength steel cords , 2011 .

[26]  Antonio Alves Dias,et al.  Glulam beams reinforced with FRP externally-bonded: theoretical and experimental evaluation , 2011 .

[27]  F. Arriaga,et al.  Simplified Model for Strength Assessment of Timber Beams Joined by Bonded Plates , 2013 .