Evaluation of surgical gamma probes for radioguided sentinel node localisation

Abstract. By using a surgical gamma probe after peritumoral injection of a radioactive tracer, the surgeon can identify the sentinel, or first, nodal site of regional metastasis in clinically node-negative patients. In the near future, the pathological status of this node will have an important impact on the treatment strategy in breast cancer and melanoma patients. This article reviews the necessary requirements for the instrument, such as: absolute sensitivity, spectral resolution, angular sensitivity and response ratio to the radioactive source at depth. In addition, ergonomic characteristics are important. The surgeon must consider the above characteristics, as they influence operational handling. Four commercially available surgical gamma probes were subjected to laboratory tests to appraise the extent to which they fulfilled these criteria. The results for each gamma probe are summarised and discussed.

[1]  R. Cabanas,et al.  An approach for the treatment of penile carcinoma , 1977, Cancer.

[2]  R. Bares,et al.  The radiation dose to surgical personnel during intraoperative radioimmunoscintimetry , 1992, European Journal of Nuclear Medicine.

[3]  B. Kapteijn Biopsy of the sentinel node in melanoma, penile carcinoma and breast carcinoma: The case for lymphatic mapping , 1997 .

[4]  D. Eshima,et al.  Lymphoscintigraphy, the sentinel node concept, and the intraoperative gamma probe in melanoma, breast cancer, and other potential cancers. , 1997, Seminars in nuclear medicine.

[5]  G. Ege,et al.  Determination of depth distribution of internal mammary lymph nodes on lateral lymphoscintigraphy. , 1985, Clinical radiology.

[6]  A. Cochran,et al.  Intraoperative lymphatic mapping and selective cervical lymphadenectomy for early-stage melanomas of the head and neck. , 1993, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.

[7]  Van Eck Three-dimensional teletherapy treatment planning : the technique, an analysis of the quantitative use of Computed Tomography, and models for dose computation of clinical photon- and electron beams , 1986 .

[8]  B. Lindskoug,et al.  Tissue heterogeneity in the anterior chest wall and its influence on radiation therapy of the internal mammary lymph nodes. , 1976, Acta radiologica: therapy, physics, biology.

[9]  C. Ma,et al.  BEAM: a Monte Carlo code to simulate radiotherapy treatment units. , 1995, Medical physics.

[10]  J. H. Hubbell,et al.  XCOM: Photon cross sections on a personal computer , 1987 .