Synchronous Luminescence Spectroscopy: Methodology and Applicability

This paper discusses the figures of merit associated with the synchronous luminescence (SL) technique in multicomponent analysis of complex samples. Spectral interferences and experimental factors that influence the choice of experimental conditions are investigated. The efficacy of SL is demonstrated in the direct determination of anthracene and 2-methylanthracene in a raw coal liquid. The application of the second-derivative technique to the SL measurement of organic samples is shown. Special emphasis is directed toward the applicability of the SL technique as a practical and cost-effective screening procedure in the routine analysis of complex organic samples.

[1]  T. Vo‐Dinh,et al.  Analysis of a workplace air particulate sample by synchronous luminescence and room-temperature phosphorescence. , 1981, Analytical chemistry.

[2]  Richard B. Gammage,et al.  Singlet-triplet energy difference as a parameter of selectivity in synchronous phosphorimetry , 1978 .

[3]  I. Evett,et al.  Prediction of peak wavelengths and intensities in synchronously excited fluorescence emission spectra , 1977 .

[4]  E. Davidson,et al.  Application of the method of rank annihilation to quantitative analyses of multicomponent fluorescence data from the video fluorometer , 1978 .

[5]  T. Vo‐Dinh,et al.  Multicomponent analysis by synchronous luminescence spectrometry. , 1978, Analytical chemistry.

[6]  J. Lloyd Limitations of synchronous luminescence spectrometry in multicomponent analysis. Comments , 1980 .

[7]  T. Vo‐Dinh,et al.  Direct determination of selected polynuclear aromatic hydrocarbons in a coal liquefaction product by synchronous luminescence techniques , 1981 .

[8]  T. Vo‐Dinh,et al.  Identification and quantification of polynuclear aromatic compounds in synthoil by room-temperature phosphorimetry , 1980 .

[9]  E. Weiner Equivalence of simultaneous scanning and three-dimensional plotting of fluorescence spectra , 1978 .

[10]  T. Vo‐Dinh,et al.  Synchronous spectroscopy for analysis of polynuclear aromatic compounds , 1978 .

[11]  L. Smith,et al.  Binding of benzo [a]pyrene to epidermal DNA and RNA as detected by synchronous luminescence spectrometry at 77 K. , 1980, Journal of biochemical and biophysical methods.

[12]  J. Lloyd,et al.  Synchronized Excitation of Fluorescence Emission Spectra , 1971 .

[13]  J. Winefordner,et al.  Limitations of synchronous luminescence spectrometry in multicomponent analysis , 1978 .

[14]  J. L. Stuart,et al.  Automated three-dimensional plotter for fluorescence measurements , 1978 .