An on-line diagnostic method for open-circuit switch faults in NPC multilevel converters

On-line condition monitoring is of paramount importance for multilevel converters used in safety-critical applications. A novel on-line diagnostic method for detecting open-circuit switch faults in neutral-point-clamped (NPC) multilevel converters is introduced in this paper. The principle of this method is based on monitoring the abnormal variation of the dc-bus neutral-point current in combination with the existing information on instantaneous switching states and phase currents. Advantages of this method include simpler implementation and faster detection speed compared to other existing diagnostic methods in the literature. In this method, only one additional current sensor is required for measuring the de-bus neutral-point current, therefore the implementation cost is low. Simulation and experimental results based on a lab-scale 50 kVA adjustable speed drive (ASD) with a three-level NPC inverter validate the efficacy of this novel diagnostic method.

[1]  Thomas A. Lipo,et al.  Fast-clamped short-circuit protection of IGBT's , 1999 .

[2]  Edith Clarke,et al.  Determination of Instantaneous Currents and Voltages by Means of Alpha, Beta, and Zero Components , 1951, Transactions of the American Institute of Electrical Engineers.

[3]  F. Blaabjerg,et al.  Method for Detecting an Open-Switch Fault in a Grid-Connected NPC Inverter System , 2012, IEEE Transactions on Power Electronics.

[4]  G. Nicoletti,et al.  Fast power cycling test of IGBT modules in traction application , 1997, Proceedings of Second International Conference on Power Electronics and Drive Systems.

[5]  Frede Blaabjerg,et al.  Open-Switch Fault Detection Method of a Back-to-Back Converter Using NPC Topology for Wind Turbine Systems , 2015, IEEE Transactions on Industry Applications.

[6]  A. M. S. Mendes,et al.  Three-level NPC inverter fault diagnosis by the Average Current Park's Vector approach , 2012, 2012 XXth International Conference on Electrical Machines.

[7]  Dong-Seok Hyun,et al.  Detection Method for Open-Circuit Fault in Neutral-Point-Clamped Inverter Systems , 2009, IEEE Transactions on Industrial Electronics.

[8]  Hirofumi Akagi,et al.  A New Neutral-Point-Clamped PWM Inverter , 1981, IEEE Transactions on Industry Applications.

[9]  Bin Wu,et al.  Powering the Future of Industry: High-Power Adjustable Speed Drive Topologies , 2012, IEEE Industry Applications Magazine.

[10]  Nabeel A. O. Demerdash,et al.  Diagnosis of open-circuit switch faults in multilevel active-NPC (ANPC) inverters , 2014, 2014 IEEE Transportation Electrification Conference and Expo (ITEC).

[11]  Bin Lu,et al.  A Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters , 2008, 2008 IEEE Industry Applications Society Annual Meeting.