Why, how and when do we need to optimize the setting of cardiac resynchronization therapy?

Current cardiac resynchronization therapy (CRT) devices allow manipulation of the atrioventricular (AV) and interventricular (VV) timings in order to maximize the left ventricular (LV) performance. Multiple echocardiographic and non-echocardiographic methods have been proposed to optimize AV and VV intervals but no consensus has been reached on which methodology should preferably be used. Furthermore, different physiologic conditions, such as rest and exercise, may markedly change LV loading conditions, and therefore an optimal setting determined at rest may be different during exercise. The present article reviews current methodologies to optimize AV and VV interval and discuss why, when and how optimization of these delays may be performed based on current evidence. Moreover, an overview of the results of the multicenter trials on AV and VV intervals optimization is provided.

[1]  Jacques Victor,et al.  Programming Optimal Atrioventricular Delay in Dual Chamber Pacing Using Peak Endocardial Acceleration: Comparison with a Standard Echocardiographic Procedure , 2003, Pacing and clinical electrophysiology : PACE.

[2]  J. McMurray,et al.  How should we optimize cardiac resynchronization therapy? , 2008, European heart journal.

[3]  Jeroen J. Bax,et al.  Results of the Predictors of Response to CRT (PROSPECT) Trial , 2008, Circulation.

[4]  Jeroen J. Bax,et al.  Noninvasive Imaging in Cardiac Resynchronization Therapy—Part 2: Follow‐up and Optimization of Settings , 2008, Pacing and clinical electrophysiology : PACE.

[5]  M. Facchini,et al.  Simultaneous vs. sequential biventricular pacing in dilated cardiomyopathy: an acute hemodynamic study , 2003, European journal of heart failure.

[6]  The Optimized V‐V Interval Determined by Interventricular Conduction Times Versus Invasive Measurement by LVdP/dtMAX , 2008, Journal of cardiovascular electrophysiology.

[7]  A. Hughes,et al.  Haemodynamic effects of changes in atrioventricular and interventricular delay in cardiac resynchronisation therapy show a consistent pattern: analysis of shape, magnitude and relative importance of atrioventricular and interventricular delay , 2006, Heart.

[8]  Markus Roos,et al.  Comparison of different approaches for optimization of atrioventricular and interventricular delay in biventricular pacing. , 2008, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[9]  J. Oh,et al.  Echocardiographic parameters of mechanical synchrony in healthy individuals. , 2009, American Journal of Cardiology.

[10]  Jiang Ding,et al.  A Prospective Comparison of AV Delay Programming Methods for Hemodynamic Optimization during Cardiac Resynchronization Therapy , 2007, Journal of cardiovascular electrophysiology.

[11]  A. Waggoner,et al.  Randomized prospective trial of atrioventricular delay programming for cardiac resynchronization therapy. , 2004, Heart rhythm.

[12]  Giuseppe Boriani,et al.  Randomized comparison of simultaneous biventricular stimulation versus optimized interventricular delay in cardiac resynchronization therapy. The Resynchronization for the HemodYnamic Treatment for Heart Failure Management II implantable cardioverter defibrillator (RHYTHM II ICD) study. , 2006, American heart journal.

[13]  S. Kapetanakis,et al.  Optimization of Cardiac Resynchronization Therapy , 2008, Echocardiography.

[14]  J. Daubert,et al.  The effect of cardiac resynchronization on morbidity and mortality in heart failure. , 2005, The New England journal of medicine.

[15]  D. Tamborero,et al.  Optimizing the programation of cardiac resynchronization therapy devices in patients with heart failure and left bundle branch block. , 2007, The American journal of cardiology.

[16]  Ladislav Dušek,et al.  A Fast and Simple Echocardiographic Method of Determination of the Optimal Atrioventricular Delay in Patients After Biventricular Stimulation , 2004, Pacing and clinical electrophysiology : PACE.

[17]  Cheuk-Man Yu,et al.  The role of repeating optimization of atrioventricular interval during interim and long-term follow-up after cardiac resynchronization therapy. , 2008, International journal of cardiology.

[18]  K. Werdan,et al.  Impedance cardiography: a useful and reliable tool in optimization of cardiac resynchronization devices. , 2007, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[19]  Stefan Sack,et al.  Long-term clinical effect of hemodynamically optimized cardiac resynchronization therapy in patients with heart failure and ventricular conduction delay. , 2002, Journal of the American College of Cardiology.

[20]  D. Delurgio,et al.  Cardiac resynchronization in chronic heart failure. , 2002, The New England journal of medicine.

[21]  David Tamborero,et al.  Electrocardiographic Optimization of Interventricular Delay in Cardiac Resynchronization Therapy: A Simple Method to Optimize the Device , 2007, Journal of cardiovascular electrophysiology.

[22]  A. Coats,et al.  Doppler ultrasonic measurement of cardiac output: reproducibility and validation. , 1990, European heart journal.

[23]  M. Haissaguerre,et al.  Echocardiographic assessment during exercise of heart failure patients with cardiac resynchronization therapy. , 2006, The American journal of cardiology.

[24]  J. Daubert,et al.  Effects of multisite biventricular pacing in patients with heart failure and intraventricular conduction delay. , 2001, The New England journal of medicine.

[25]  Prashanthan Sanders,et al.  Echocardiographic parameters of ventricular dyssynchrony validation in patients with heart failure using sequential biventricular pacing. , 2004, Journal of the American College of Cardiology.

[26]  S. Kaplan,et al.  Measurement of Right and Left Ventricular Systolic Time Intervals by Echocardiography , 1975, Circulation.

[27]  E. Foster,et al.  Reduced Ventricular Volumes and Improved Systolic Function With Cardiac Resynchronization Therapy: A Randomized Trial Comparing Simultaneous Biventricular Pacing, Sequential Biventricular Pacing, and Left Ventricular Pacing , 2007, Circulation.

[28]  Angelo Branzi,et al.  Interventricular delay interval optimization in cardiac resynchronization therapy guided by echocardiography versus guided by electrocardiographic QRS interval width. , 2008, The American journal of cardiology.

[29]  Albert Meijer,et al.  Effect of optimizing the VV interval on left ventricular contractility in cardiac resynchronization therapy. , 2004, The American journal of cardiology.

[30]  A. Righetti,et al.  Optimizing sequential biventricular pacing using radionuclide ventriculography. , 2005, Heart rhythm.

[31]  A. Fraser,et al.  A critical comparison of echocardiographic measurements used for optimizing cardiac resynchronization therapy: stroke distance is best , 2009, European journal of heart failure.

[32]  Andrew P. Kramer,et al.  Effect of pacing chamber and atrioventricular delay on acute systolic function of paced patients with congestive heart failure. The Pacing Therapies for Congestive Heart Failure Study Group. The Guidant Congestive Heart Failure Research Group. , 1999, Circulation.

[33]  Milton Packer,et al.  Cardiac resynchronization in chronic heart failure. , 2002, The New England journal of medicine.

[34]  L. Padeletti,et al.  Temporal variation in optimal atrioventricular and interventricular delay during cardiac resynchronization therapy. , 2006, Journal of cardiac failure.

[35]  S. Barold,et al.  Echocardiographic optimization of the atrioventricular and interventricular intervals during cardiac resynchronization. , 2008, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[36]  Jeroen J. Bax,et al.  Echocardiography and noninvasive imaging in cardiac resynchronization therapy: results of the PROSPECT (Predictors of Response to Cardiac Resynchronization Therapy) study in perspective. , 2009, Journal of the American College of Cardiology.

[37]  R. Cody,et al.  Comparative accuracy of Doppler echocardiographic methods for clinical stroke volume determination. , 1990, American heart journal.

[38]  B. Kristensen,et al.  Sequential Versus Simultaneous Biventricular Resynchronization for Severe Heart Failure: Evaluation by Tissue Doppler Imaging , 2002, Circulation.

[39]  J. Daubert,et al.  Cardiac resynchronization with sequential biventricular pacing for the treatment of moderate-to-severe heart failure. , 2005, Journal of the American College of Cardiology.

[40]  A. Hamer,et al.  Long‐Term Variations in Optimal Programming of Cardiac Resynchronization Therapy Devices , 2005, Pacing and clinical electrophysiology : PACE.

[41]  M. Haissaguerre,et al.  Echocardiographic study of the optimal atrioventricular delay at rest and during exercise in recipients of cardiac resynchronization therapy systems. , 2009, Heart rhythm.

[42]  Angelo Branzi,et al.  Cardiac Resynchronization Therapy: Variations in Echo‐Guided Optimized Atrioventricular and Interventricular Delays During Follow‐Up , 2007, Echocardiography.