Fluticasone propionate/salmeterol hydrofluoroalkane via metered‐dose inhaler with integrated dose counter: performance and patient satisfaction

Currently, patients have to keep track of doses to determine when to replace their metered‐dose inhalers (MDIs). This study evaluated the performance and patient satisfaction of a novel MDI with an integrated dose counter. In an open‐label study at 38 outpatient centres, patients ≥12 years old with asthma or chronic obstructive pulmonary disease (COPD) received two actuations of fluticasone propionate/salmeterol 125/25 μg (115/21 μg ex‐actuator) hydrofluoroalkane (ADVAIR® HFA) via MDI with counter twice a day until all 120 actuations were completed. Concordance between counter and diary recordings in patients who reported use of ≥90% of labelled actuations (completer population, n = 228) was high (discrepancy rate of 0.94%) and the incidence of device firing without changes in counter readings was low (0.13%). Mean expected actuations based on canister weights (114) were slightly lower than mean counter (121) and diary reported actuations (120). Upon study completion, 95% of patients were satisfied with the dose counter and 92% agreed it would help prevent them from running out of medication. Safety assessments (intent‐to‐treat population, n = 237) indicated that the drug was well tolerated. This integrated MDI counter may help patients maintain better disease control by enabling them to accurately track their medication supply.

[1]  B. Chipps,et al.  Dose counting and the use of pressurized metered-dose inhalers: running on empty. , 2006, Annals of allergy, asthma & immunology : official publication of the American College of Allergy, Asthma, & Immunology.

[2]  B. Rubin,et al.  How do patients determine that their metered-dose inhaler is empty? , 2004, Chest.

[3]  D. Au,et al.  Inhaled corticosteroids in chronic obstructive pulmonary disease and risk of death and hospitalization: time-dependent analysis. , 2003, American journal of respiratory and critical care medicine.

[4]  L. Hendeles,et al.  Accuracy of three electronic monitors for metered-dose inhalers. , 2002, Chest.

[5]  J. Oppenheimer,et al.  The misconception of using floating patterns as an accurate means of measuring the contents of metered-dose inhaler devices. , 2001, Annals of allergy, asthma & immunology : official publication of the American College of Allergy, Asthma, & Immunology.

[6]  C. Rand,et al.  Measurement of children's asthma medication adherence by self report, mother report, canister weight, and Doser CT. , 2000, Annals of allergy, asthma & immunology : official publication of the American College of Allergy, Asthma, & Immunology.

[7]  C. Rand,et al.  Reliability of the model MC-311 MDI chronolog. , 1999, The Journal of allergy and clinical immunology.

[8]  C. Rand,et al.  Validation of the Doser, a new device for monitoring metered-dose inhaler use. , 1998, The Journal of allergy and clinical immunology.

[9]  J. Rohay,et al.  Compliance with inhaled medications: The relationship between diary and electronic monitor , 1998, Annals of behavioral medicine : a publication of the Society of Behavioral Medicine.

[10]  L. Hendeles,et al.  Reliability of the Medtrac MDI Chronolog. , 1997, Journal of Allergy and Clinical Immunology.

[11]  C. Rand,et al.  Noncompliance and treatment failure in children with asthma. , 1996, The Journal of allergy and clinical immunology.

[12]  Baldwin Jl,et al.  How patients determine when to replace their metered-dose inhalers. , 1995 .

[13]  R. Simon,et al.  How patients determine when to replace their metered-dose inhalers. , 1995, Annals of allergy, asthma & immunology : official publication of the American College of Allergy, Asthma, & Immunology.

[14]  G. Boyd The continued need for metered dose inhalers. , 1995, Journal of aerosol medicine : the official journal of the International Society for Aerosols in Medicine.

[15]  W. Greisner,et al.  Metered-dose inhalers: the specified number of sprays. , 1993, JAMA.

[16]  P. Gergen,et al.  An economic evaluation of asthma in the United States. , 1992, The New England journal of medicine.

[17]  C. Rand,et al.  A nebulizer chronolog to monitor compliance with inhaler use. , 1991, The American journal of medicine.

[18]  R. Patterson,et al.  Potentially fatal asthma: the problem of noncompliance. , 1991, Annals of allergy.

[19]  S. Spector,et al.  Compliance in clinical trials of two nonbronchodilator, antiasthma medications. , 1991, Annals of allergy.

[20]  S. Spector,et al.  Compliance of patients with asthma with an experimental aerosolized medication: implications for controlled clinical trials. , 1986, The Journal of allergy and clinical immunology.