Comparison of different methods to calibrate torsional spring constant and photodetector for atomic force microscopy friction measurements in air and liquid.

A number of atomic force microscopy cantilevers have been exhaustively calibrated by a number of techniques to obtain both normal and frictional force constants to evaluate the relative accuracy of the different methods. These were of either direct or indirect character-the latter relies on cantilever resonant frequencies. The so-called Sader [Rev. Sci. Instrum. 70, 3967 (1999)] and Cleveland [Rev. Sci. Instrum. 64, 403 (1993)] techniques are compared for the normal force constant calibration and while agreement was good, a systematic difference was observed. For the torsional force constants, all the techniques displayed a certain scatter but the agreement was highly encouraging. By far the simplest technique is that of Sader, and it is suggested in view of this validation that this method should be generally adopted. The issue of the photodetector calibration is also addressed since this is necessary to obtain the cantilever twist from which the torsional force is calculated. Here a technique of obtaining the torsional photodetector sensitivity by combining the direct and indirect methods is proposed. Direct calibration measurements were conducted in liquid as well as air, and a conversion factor was obtained showing that quantitative friction measurements in liquid are equally feasible provided the correct calibration is performed.

[1]  S. Perry Scanning Probe Microscopy Measurements of Friction , 2004 .

[2]  John E. Sader,et al.  Normal and torsional spring constants of atomic force microscope cantilevers , 2004 .

[3]  Richard M. Pashley,et al.  Direct measurement of colloidal forces using an atomic force microscope , 1991, Nature.

[4]  I. Larson,et al.  Atomic force microscopy and direct surface force measurements (IUPAC Technical Report) , 2005 .

[5]  Robert W. Carpick,et al.  Lateral force calibration in atomic force microscopy: A new lateral force calibration method and general guidelines for optimization , 2006 .

[6]  R. Proksch,et al.  Noninvasive determination of optical lever sensitivity in atomic force microscopy , 2006 .

[7]  J. Sader,et al.  In-plane deformation of cantilever plates with applications to lateral force microscopy , 2004 .

[8]  Timothy Senden,et al.  Experimental Determination of Spring Constants in Atomic Force Microscopy , 1994 .

[9]  Robert W. Carpick,et al.  Calibration of frictional forces in atomic force microscopy , 1996 .

[10]  G. Somorjai,et al.  Continuum Force Microscopy Study of the Elastic Modulus, Hardness and Friction of Polyethylene and Polypropylene Surfaces , 1998 .

[11]  P. Hansma,et al.  A nondestructive method for determining the spring constant of cantilevers for scanning force microscopy , 1993 .

[12]  Vladimir V. Tsukruk,et al.  Spring constants of composite ceramic/gold cantilevers for scanning probe microscopy , 1999 .

[13]  M. Salmeron,et al.  Scratching the Surface: Fundamental Investigations of Tribology with Atomic Force Microscopy. , 1997, Chemical reviews.

[14]  H. Brumer,et al.  Friction and forces between cellulose model surfaces: a comparison. , 2006, Journal of colloid and interface science.

[15]  D. F. Evans,et al.  Structure and Frictional Properties of Self-Assembled Surfactant Monolayers , 1996 .

[16]  P. Tordjeman,et al.  Cantilever calibration for nanofriction experiments with atomic force microscope , 2005 .

[17]  D. F. Evans,et al.  Lateral Force Microscopy Study on the Shear Properties of Self-Assembled Monolayers of Dialkylammonium Surfactant on Mica , 1994 .

[18]  James W. G. Tyrrell,et al.  Analysis of atomic force microscopy data for deformable materials , 2004 .

[19]  J. Sader,et al.  Method for the calibration of atomic force microscope cantilevers , 1995 .

[20]  J. Sader,et al.  Calibration of rectangular atomic force microscope cantilevers , 1999 .

[21]  I. Larson,et al.  Calibration of the torsional spring constant and the lateral photodiode response of frictional force microscopes , 2000 .

[22]  Jean-Pierre Celis,et al.  Calibration procedures for frictional measurements with a lateral force microscope , 1996 .

[23]  John E. Sader,et al.  Parallel beam approximation for V‐shaped atomic force microscope cantilevers , 1995 .

[24]  M. Rutland,et al.  Thermal calibration of photodiode sensitivity for atomic force microscopy , 2006 .

[25]  Cross talk between bending, twisting, and buckling modes of three types of microcantilever sensors , 2004 .

[26]  Biggs,et al.  Force Calibration in Lateral Force Microscopy. , 2000, Journal of colloid and interface science.

[27]  J. Sader Frequency response of cantilever beams immersed in viscous fluids with applications to the atomic force microscope , 1998 .

[28]  John E. Sader,et al.  Torsional frequency response of cantilever beams immersed in viscous fluids with applications to the atomic force microscope , 2002 .

[29]  J. Neumeister,et al.  Lateral, normal, and longitudinal spring constants of atomic force microscopy cantilevers , 1994 .

[30]  M. Troyon,et al.  A new calibration method of the lateral contact stiffness and lateral force using modulated lateral force microscopy , 1999 .

[31]  Izhak Etsion,et al.  An improved wedge calibration method for lateral force in atomic force microscopy , 2003 .

[32]  N. Amer,et al.  Simultaneous measurement of lateral and normal forces with an optical‐beam‐deflection atomic force microscope , 1990 .

[33]  Sangmin Jeon,et al.  Torsional spring constant obtained for an atomic force microscope cantilever , 2004 .

[34]  Simon Biggs,et al.  Quantitative comparison of three calibration techniques for the lateral force microscope , 2001 .

[35]  M. Rutland,et al.  Friction Measurement Between Polyester Fibres Using the Fibre Probe SPM , 2006 .

[36]  J. Bechhoefer,et al.  Calibration of atomic‐force microscope tips , 1993 .

[37]  Rutland,et al.  Tip friction - torsional spring constant determination. , 2000, Colloids and surfaces. B, Biointerfaces.