Towards the development of an explosives detection system using Neutron Resonance Radiography

Detection of conventional explosives remains a challenge to air security, as indicated by recent reports detailing lapses in security screening and new requirements that mandate screening 100% of checked luggage. Neutron Resonance Radiography (NRR) has been under investigation as a supplement to conventional x-ray systems as a non-invasive, non-destructive means of detecting explosive material in checked luggage. Using fast (1-6 MeV) neutrons produced by an accelerator-based D(d,n)3He reaction and a scintillator-coupled CCD camera, NRR provides both an imaging capability and the ability to determine the chemical composition of materials in baggage or cargo. Theoretical studies and simulations have shown the potential of NRR. This thesis takes the first step towards experimental implementation using a deuterium target for multiple-element discrimination. A new neutron source has been developed to provide the high-flux neutron beam required for NRR while simultaneously minimizing gamma ray production. The gas target incorporates a 4 atm D2 gas chamber, separated from the accelerator beamline with thin, 5 tm tungsten or 7 im molybdenum foils supported by a honeycomb lattice structure to increase structural integrity and provide a heat removal pathway. An argon gas cooling system is incorporated to cool the target and thus increase the neutron flux. The gas target has been shown to withstand 3.0 MeV deuteron beam currents in excess of 35 pLA for extended periods without failure, resulting in a neutron flux of 6.6 x 107 neutrons/sr/pA/s. A neutron imaging system was designed to detect the fast neutrons and produce a digital image of objects for analysis. Two neutron detectors, Eljen plastic scintillator EJ-200 and a ZnS(Ag) scintillating screen were tested for their suitability to NRR. Although ZnS(Ag) has a lower detection efficiency, its resolution, minimal light dispersion, and insensitivity to gamma rays made it the more favorable material. An Apogee Instruments, Inc., Alta U9 CCD camera was used to record the light from the scintillator to create radiographs. The gas target and neutron detection system were used to evaluate the results of experimental work to determine the feasibility of NRR. These experiments ultimately indicated that although NRR has promise, significant challenges regarding neutron flux and image processing must be overcome before the technique can be implemented as an explosives detection system. Suggestions are made for improvements. Thesis Supervisor: Richard Lanza Title: Senior Research Scientist Thesis Reader: Jeffrey Coderre Title: Associate Professor

[1]  L. Nilsson,et al.  Neutron sources for basic physics and applications , 1983 .

[2]  George Vourvopoulos,et al.  Non-destructive characterization using pulsed fast-thermal neutrons , 1995 .

[3]  G. Knoll Radiation Detection And Measurement, 3rd Ed , 2009 .

[4]  Tsahi Gozani,et al.  The role of neutron based inspection techniques in the post 9/11/01 era , 2004 .

[5]  Thomas J. Yule,et al.  Fast-neutron transmission spectroscopy for illicit substance detection , 1996, Other Conferences.

[6]  M. Month,et al.  Physics of particle accelerators: Volume 1 , 1987 .

[7]  Tsahi Gozani,et al.  Time of flight fast neutron radiography , 1995 .

[8]  S. Whittlestone Neutron distributions from the deuteron bombardment of a thick beryllium target , 1977 .

[9]  Chris Quillen Mass Casualty Bombings Chronology , 2002 .

[10]  Brandon William Blackburn,et al.  High-power target development for accelerator-based neutron capture therapy , 2002 .

[11]  Ronald Allen Knief,et al.  Nuclear engineering : theory and technology of commercial nuclear power , 2008 .

[12]  J. Meadows,et al.  A high-current deuterium gas target for neutron nuclear data research , 1980 .

[13]  Gongyin Chen,et al.  Fast neutron resonance radiography for elemental imaging: theory and applications , 2001, 2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310).

[14]  Jimmie C. Oxley,et al.  Explosives detection: potential problems , 1995, Other Conferences.

[15]  Bartholomew Elias Aviation Security: Issues Before Congress Since September 11, 2001 , 2004 .

[16]  M D NIELSEN,et al.  Cosmic Rays , 1930, Nature.

[17]  J. Boone,et al.  Lens coupling efficiency: derivation and application under differing geometrical assumptions. , 1997, Medical physics.

[18]  D. Salerno,et al.  Windowless targets for intense beams , 2001 .

[19]  A. Riedel,et al.  Intense Neutron Source Target Test Facility: A 200 kV, 200 mA dc, Deuterium Ion Accelerator , 1979, IEEE Transactions on Nuclear Science.

[20]  Jimmie C. Oxley,et al.  The Chemistry of Explosives , 1998 .

[21]  Gideon Engler,et al.  A method for detection of explosives based on nuclear resonance absorption of gamma rays in 14N , 1994 .

[22]  W. R. McMurray,et al.  Development of high pressure deuterium gas targets for the generation of intense mono-energetic fast neutron beams , 1999 .

[23]  Shuanghe Shi An accelerator-based neutron imaging system and its application to detection of corrosion in aircraft , 1995 .

[24]  Lawrence J. Myers,et al.  Dog-handler team as a detection system for explosives: a tail to be told , 1992, Optics + Photonics.

[25]  Richard C. Lanza,et al.  Windowless gas targets for neutron production , 1997, Other Conferences.

[26]  Tsahi Gozani,et al.  Thermal neutron analysis (TNA) explosive detection based on electronic neutron generators , 1995 .

[27]  J. Steinfeld,et al.  Explosives detection: a challenge for physical chemistry. , 1998, Annual review of physical chemistry.

[28]  J. Yinon,et al.  Field detection and monitoring of explosives , 2002 .

[29]  Tsahi Gozani,et al.  Thermal neutron analysis technology , 1997, Defense + Security Symposium.

[30]  E. Kamykowski,et al.  A Contraband Detection System Proof-of-Principle Device Using Electrostatic Acceleration , 1996 .

[31]  Ady Hershcovitch,et al.  A plasma window for transmission of particle beams and radiation from vacuum to atmosphere for various applications , 1998 .

[32]  D. Cowgill,et al.  Intense Neutron Source Development for Use in Cancer Therapy , 1981, IEEE Transactions on Nuclear Science.