Abstract Flight qualification of ion thrusters typically requires testing on the order of 10,000 hours. Extensive knowledge of wear mechanisms and rates is necessary to establish design confidence prior to long duration tests. Consequently, real-time erosion rate measurements offer the potential both to reduce development costs and to enhance knowledge of the dependency of component wear on operating conditions. Several previous studies have used laser-induced fluorescence (LIF) to measure real-time, in situ erosion rates of ion thruster accelerator grids. Those studies provided only relative measurements of the erosion rate. In the present investigation, a molybdenum tube was resistively heated such that the evaporation rate yielded densities within the tube on the order of those expected from accelerator grid erosion. This work examines the suitability of the density cell as an absolute calibration source for LIF measurements, and the intrinsic error was evaluated. Nomenclature a,b,c,d = coefficients for vapor pressure calculation A = view factor variable A
[1]
C. B. Alcock,et al.
Vapour Pressure Equations for the Metallic Elements: 298–2500K
,
1984
.
[2]
John R. Anderson,et al.
An overview of the results from an 8200 hour wear test of the NSTAR ion thruster
,
1999
.
[3]
R. S. Turley,et al.
Erosion rate diagnostics in ion thrusters using laser-induced fluorescence
,
1993
.
[4]
A. N. Nesmei︠a︡nov.
Vapour Pressure of the Elements
,
1963
.
[5]
Mark Crofton.
Laser spectroscopic study of the T5 ion thruster
,
1995
.
[6]
F. Orsitto,et al.
MoI density measurements by laser induced fluorescence spectroscopy
,
1995
.
[7]
Plasma erosion rate diagnostics using laser-induced fluorescence
,
1992
.