System Stability Impact of Large-Scale and Distributed Solar Photovoltaic Generation: The Case of Ontario, Canada

This paper presents a comparative investigation of (PV) effect on system stability at different penetration levels. Three different scenarios with their relevant dynamic models are considered, namely, distributed units, and centralized farms with and without voltage regulation capabilities. Based on these models, the impact is examined through eigenvalue, voltage stability and transient stability analyses using real network data pertaining to Ontario and its neighboring systems. This impact is quantized in monetary terms based on the long run marginal cost of electricity production in Ontario. It is demonstrated that distributed solar PV generators are significantly more advantageous, from the stability point of view, than solar farms.

[1]  K Strunz,et al.  Modeling Guidelines and a Benchmark for Power System Simulation Studies of Three-Phase Single-Stage Photovoltaic Systems , 2011, IEEE Transactions on Power Delivery.

[2]  D. Kirschen,et al.  Fundamentals of power system economics , 1991 .

[3]  V. Vittal,et al.  Impact of Increased Penetration of DFIG-Based Wind Turbine Generators on Transient and Small Signal Stability of Power Systems , 2010, IEEE Transactions on Power Systems.

[4]  I T Papaioannou,et al.  Modeling and Field Measurements of Photovoltaic Units Connected to LV Grid. Study of Penetration Scenarios , 2011, IEEE Transactions on Power Delivery.

[5]  Goran Strbac,et al.  Fundamentals of Power System Economics: Kirschen/Power System Economics , 2005 .

[6]  Raja Ayyanar,et al.  Control strategy to mitigate the impact of reduced inertia due to doubly fed induction generators on large power systems , 2011, 2011 IEEE Power and Energy Society General Meeting.

[7]  David Infield,et al.  Network power-flow analysis for a high penetration of distributed generation , 2006 .

[8]  Peter W. Sauer,et al.  Power System Dynamics and Stability , 1997 .

[9]  O. Wasynczuk Modeling and Dynamic Performance of a Line-Commutated Photovoltaic Inverter System , 1989, IEEE Power Engineering Review.

[10]  I. Erlich,et al.  Impact of large wind power generation on frequency stability , 2006, 2006 IEEE Power Engineering Society General Meeting.

[11]  M. Tartaglia,et al.  Electrical Impact of Photovoltaic Plant in Distributed Network , 2007, IEEE Transactions on Industry Applications.

[12]  Kankar Bhattacharya,et al.  Modeling and performance analysis of large solar photo-voltaic generation on voltage stability and inter-area oscillations , 2011 .

[13]  H. H. Happ,et al.  Power System Control and Stability , 1979, IEEE Transactions on Systems, Man, and Cybernetics.

[14]  N. Kakimoto,et al.  Voltage Control of Photovoltaic Generator in Combination With Series Reactor , 2011, IEEE Transactions on Sustainable Energy.

[15]  M. Thomson,et al.  Network Power-Flow Analysis for a High Penetration of Distributed Generation , 2006, IEEE Transactions on Power Systems.

[16]  David Infield,et al.  Impact of widespread photovoltaics generation on distribution systems , 2007 .

[17]  Syed Nasar,et al.  Electric Energy Systems , 1995, Energy for Sustainable Society.

[18]  E. Muljadi,et al.  Effect of Variable Speed Wind Turbine Generator on Stability of a Weak Grid , 2007, IEEE Transactions on Energy Conversion.

[19]  P. S. Dokopoulos,et al.  A Correlation Index to Evaluate Impact of PV Installation on Joule Losses , 2011, IEEE Transactions on Power Systems.

[20]  M. Kazerani,et al.  Dynamic Modeling and Performance Analysis of a Grid-Connected Current-Source Inverter-Based Photovoltaic System , 2011, IEEE Transactions on Sustainable Energy.

[21]  Satoshi Suzuki,et al.  Grid Stabilization by Use of an Energy Storage System for a Large-Scale PV Generation Plant , 2009 .

[22]  O. Wasynczuk,et al.  Modeling and Dynamic Performance of a Self-Commutated Photovoltaic Inverter System , 1989, IEEE Power Engineering Review.

[23]  F. Fernández-Bernal,et al.  Modelling of photovoltaic plants for power system dynamic studies , 2002 .