Fault diagnosis of voltage sensor in grid-connected 3-phase voltage source converters

This paper proposes a fault diagnosis method of the line-to-line voltage sensors in grid-connected 3-phase voltage source converters. The line-to-line voltage sensors are an essential device to obtain the information of the grid side voltages for controlling the converters. If there are problems in the voltage sensors by some faults, the controller obtains wrong information of the grid voltage. It causes the unbalance 3 phase currents and the pulsation of the DC-link voltage even though the power grid is healthy. Therefore fault diagnosis methods are required to detect the failure and to avoid the abnormal operation. This proposed diagnosis method identifies whether the fault is at the voltage sensor or the power grid when the abnormal values are measured from the line-to-line voltage sensors. Then the fault tolerance control is possible in case of the voltage sensor fault. The proposed method can improve the system reliability by just adding some software algorithm without additional hardware circuits. The usefulness of this paper is verified through the computer simulation and experiment.

[1]  Bimal K. Bose,et al.  Investigation of fault modes of voltage-fed inverter system for induction motor drive , 1992, Conference Record of the 1992 IEEE Industry Applications Society Annual Meeting.

[2]  P. V. Sunil Nag,et al.  Detection and isolation of sensor faults , 2009 .

[3]  Farzad Rajaei Salmasi,et al.  Detection and Isolation of Speed-, DC-Link Voltage-, and Current-Sensor Faults Based on an Adaptive Observer in Induction-Motor Drives , 2011, IEEE Transactions on Industrial Electronics.

[4]  F.W. Fuchs,et al.  Voltage Sensor Fault Detection and Reconfiguration for a Doubly Fed Induction Generator , 2007, 2007 IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives.

[5]  Jorge O. Estima,et al.  Converters fault-diagnosis in PMSG drives for wind turbine applications , 2010, IECON 2010 - 36th Annual Conference on IEEE Industrial Electronics Society.

[6]  Bin Lu,et al.  A Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters , 2008, 2008 IEEE Industry Applications Society Annual Meeting.

[7]  R. Peuget,et al.  Fault detection and isolation on a PWM inverter by knowledge-based model , 1997, IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting.

[8]  D. Boroyevich,et al.  Decoupled Double Synchronous Reference Frame PLL for Power Converters Control , 2007, IEEE Transactions on Power Electronics.