Real-time monitoring and chemical profiling of a cultivation process

Abstract A method for at-line quality assessment of a cultivation process is developed in order to (1) enable improved process control, (2) enable faster detection of batch end point, and (3) enable immediate quality assessment of final product. Fluorescence excitation–emission measurements are used because they are known to reflect important properties of the fermentation process. Focus is also on important sampling issues—mainly structurally sub-optimal primary sampling methods affecting the representativity obtainable relative to the lot characteristics. Several different calibration approaches are investigated for predicting product quality (enzymatic activity). The fluorescence data are also modeled by a PARAFAC model, providing a chemically interpretable visualization of the process variation thereby enhancing the possibilities for gaining in-depth process understanding. The results of our investigations are that enzyme activity can be predicted directly from fluorescence measurements with an uncertainty comparable to the uncertainty of the chemical reference analysis for the enzyme activity. Chemical profiling of the cultivation process using PARAFAC verifies basic understanding of the cultivation process. An enzyme marker profile as well as a tryptophan (protein marker) profile is identified.

[1]  L. Olsson,et al.  Chemometric analysis of in‐line multi‐wavelength fluorescence measurements obtained during cultivations with a lipase producing Aspergillus oryzae strain , 2007, Biotechnology and bioengineering.

[2]  R. Bro,et al.  A new efficient method for determining the number of components in PARAFAC models , 2003 .

[3]  A E Humphrey,et al.  Monitoring Cell Concentration and Activity by Multiple Excitation Fluorometry , 1991, Biotechnology progress.

[4]  Dörte Solle,et al.  Chemometric modelling with two-dimensional fluorescence data for Claviceps purpurea bioprocess characterization. , 2003, Journal of biotechnology.

[5]  Kim H. Esbensen,et al.  Representative Sampling for reliable data analysis: Theory Of Sampling , 2005 .

[6]  J J Horvath,et al.  In Situ Fluorescence Cell Mass Measurements of Saccharomyces cerevisiae Using Cellular Tryptophan , 1993, Biotechnology progress.

[7]  B. Kowalski,et al.  Partial least-squares regression: a tutorial , 1986 .

[8]  Kim H. Esbensen,et al.  Representative mass reduction in sampling—a critical survey of techniques and hardware , 2004 .

[9]  Dörte Solle,et al.  Chemometric Modelling based on 2D-Fluorescence Spectra without a Calibration Measurement , 2003, Bioinform..

[10]  J. Lakowicz Principles of fluorescence spectroscopy , 1983 .

[11]  H. Law Research methods for multimode data analysis , 1984 .

[12]  Arthur E. Humphrey,et al.  Factors Affecting Culture Fluorescence When Monitoring Bioreactors , 1992 .

[13]  J. Chang,et al.  Analysis of individual differences in multidimensional scaling via an n-way generalization of “Eckart-Young” decomposition , 1970 .

[14]  Lisbeth Olsson,et al.  On-line cell mass monitoring of Saccharomyces cerevisiae cultivations by multi-wavelength fluorescence. , 2004, Journal of biotechnology.

[15]  A. E. Humphrey,et al.  Estimation of Fermentation Biomass Concentration by Measuring Culture Fluorescence , 1978, Applied and environmental microbiology.

[16]  A. Höskuldsson PLS regression methods , 1988 .

[17]  Eric R. Ziegel,et al.  Pierre Gy's Sampling Theory and Sampling Practice , 1989 .

[18]  Francis F. Pitard,et al.  Pierre Gy's Sampling Theory and Sampling Practice. Heterogeneity, Sampling Correctness, and Statistical Process Control , 1993 .

[19]  R. Bro Multiway calibration. Multilinear PLS , 1996 .

[20]  R. Bro PARAFAC. Tutorial and applications , 1997 .

[21]  N. Sidiropoulos,et al.  On the uniqueness of multilinear decomposition of N‐way arrays , 2000 .

[22]  Susan Eitelman,et al.  Matlab Version 6.5 Release 13. The MathWorks, Inc., 3 Apple Hill Dr., Natick, MA 01760-2098; 508/647-7000, Fax 508/647-7001, www.mathworks.com , 2003 .

[23]  Richard A. Harshman,et al.  Foundations of the PARAFAC procedure: Models and conditions for an "explanatory" multi-model factor analysis , 1970 .

[24]  Pierre Gy,et al.  Sampling for analytical purposes , 1998 .