A Method to Calculate Adherence to Inhaled Therapy that Reflects the Changes in Clinical Features of Asthma.

RATIONALE Currently, studies on adherence to inhaled medications report average adherence over time. This measure does not account for variations in the interval between doses, nor for errors in inhaler use. OBJECTIVES To investigate whether adherence calculated as a single area under the (concentration-time) curve (AUC) measure, incorporating the interval between doses and inhaler technique, was more reflective of patient outcomes than were current methods of assessing adherence. METHODS We attached a digital audio device (INhaler Compliance Assessment) to a dry powder inhaler. This recorded when the inhaler was used, and analysis of the audio data indicated if the inhaler had been used correctly. These aspects of inhaler use were combined to calculate adherence over time, as an AUC measure. Over a 3-month period, a cohort of patients with asthma was studied. Adherence to a twice-daily inhaler preventer therapy using this device and clinical measures were assessed. MEASUREMENTS AND MAIN RESULTS Recordings from 239 patients with severe asthma were analyzed. Average adherence that was based on the dose counter was 84.4%, whereas the ratio of expected to observed accumulated AUC, actual adherence, was 61.8% (P < 0.01). Of all the adherence measures, only adherence calculated as AUC reflected changes in asthma quality of life, β-agonist reliever use, and peak expiratory flow over the 3 months (P < 0.05 compared with other measures of adherence). CONCLUSIONS Adherence that incorporates the interval between doses and inhaler technique, and calculated as AUC, is more reflective of changes in quality of life and lung function than are the currently used measures of adherence. Clinical trial registered with www.clinicaltrials.gov (NCT 01529697).

[1]  K. Farmer,et al.  Methods for measuring and monitoring medication regimen adherence in clinical trials and clinical practice. , 1999, Clinical therapeutics.

[2]  S. Cowman,et al.  A nurse‐led intervention study: Promoting compliance with Diskus Inhaler use in asthma patients , 2014, Nursing open.

[3]  Chris Corrigan,et al.  Effect of incorrect use of dry powder inhalers on management of patients with asthma and COPD. , 2008, Respiratory medicine.

[4]  Richard B. Reilly,et al.  An Acoustic-Based Method to Detect and Quantify the Effect of Exhalation into a Dry Powder Inhaler. , 2015, Journal of aerosol medicine and pulmonary drug delivery.

[5]  M. Bala,et al.  Inhaled corticosteroids for asthma therapy: patient compliance, devices, and inhalation technique. , 2000, Chest.

[6]  Sameer Badlani,et al.  Misuse of Respiratory Inhalers in Hospitalized Patients with Asthma or COPD , 2011, Journal of General Internal Medicine.

[7]  J. Seheult,et al.  Investigating the relationship between peak inspiratory flow rate and volume of inhalation from a Diskus™ Inhaler and baseline spirometric parameters: a cross-sectional study , 2014, SpringerPlus.

[8]  D. Shaw,et al.  Efficacy and safety of maintenance and reliever combination budesonide-formoterol inhaler in patients with asthma at risk of severe exacerbations: a randomised controlled trial. , 2013, The Lancet. Respiratory medicine.

[9]  M. Weatherall,et al.  Randomized controlled trial of adherence with single or combination inhaled corticosteroid/long-acting beta-agonist inhaler therapy in asthma. , 2010, The Journal of allergy and clinical immunology.

[10]  G H Guyatt,et al.  Determining a minimal important change in a disease-specific Quality of Life Questionnaire. , 1994, Journal of clinical epidemiology.

[11]  R. Reilly,et al.  Acoustic Analysis of Inhaler Sounds From Community-Dwelling Asthmatic Patients for Automatic Assessment of Adherence , 2014, IEEE Journal of Translational Engineering in Health and Medicine.

[12]  Richard B. Reilly,et al.  A Method to Assess Adherence in Inhaler Use through Analysis of Acoustic Recordings of Inhaler Events , 2014, PloS one.

[13]  C. Rand,et al.  Derivation of adherence metrics from electronic dosing records. , 2001, Journal of clinical epidemiology.

[14]  G. Guyatt,et al.  Evaluation of impairment of health related quality of life in asthma: development of a questionnaire for use in clinical trials. , 1992, Thorax.

[15]  S. Al‐Muhsen,et al.  Improper inhaler technique is associated with poor asthma control and frequent emergency department visits , 2013, Allergy, Asthma & Clinical Immunology.

[16]  E. Dibek Mısırlıoğlu,et al.  Evaluation of inhaler technique, adherence to therapy and their effect on disease control among children with asthma using metered dose or dry powder inhalers , 2015, The Journal of asthma : official journal of the Association for the Care of Asthma.

[17]  Richard B. Reilly,et al.  A new clinically relevant method of calculating adherence , 2015 .

[18]  Richard Beasley,et al.  An audiovisual reminder function improves adherence with inhaled corticosteroid therapy in asthma. , 2007, The Journal of allergy and clinical immunology.

[19]  Ze Zhang,et al.  Adherence reporting in randomized controlled trials , 2014, Clinical trials.

[20]  Richard B. Reilly,et al.  The Acoustic Features of Inhalation can be Used to Quantify Aerosol Delivery from a Diskus™ Dry Powder Inhaler , 2014, Pharmaceutical Research.

[21]  N. Barnes,et al.  Can guideline-defined asthma control be achieved? The Gaining Optimal Asthma Control study. , 2004, American journal of respiratory and critical care medicine.

[22]  F. Dekker,et al.  Value of measuring diurnal peak flow variability in the recognition of asthma: a study in general practice. , 1998, The European respiratory journal.

[23]  Marco Lodi,et al.  Inhaler mishandling remains common in real life and is associated with reduced disease control. , 2011, Respiratory medicine.

[24]  Iman A Basheti,et al.  Checklists for Powder Inhaler Technique: A Review and Recommendations , 2014, Respiratory Care.

[25]  A. Lippman Adherence to medication. , 2005, The New England journal of medicine.

[26]  S. Wieshammer,et al.  Dry Powder Inhalers: Which Factors Determine the Frequency of Handling Errors? , 2007, Respiration.

[27]  J. Seheult,et al.  Investigating the relationship between peak inspiratory flow rate and volume of inhalation from a DiskusTM Inhaler and baseline spirometric parameters: a cross-sectional study , 2016 .

[28]  Richard B Reilly,et al.  A method of estimating inspiratory flow rate and volume from an inhaler using acoustic measurements , 2013, Physiological measurement.

[29]  J. Urquhart,et al.  Adherence to medications: insights arising from studies on the unreliable link between prescribed and actual drug dosing histories. , 2012, Annual review of pharmacology and toxicology.

[30]  R. Reilly,et al.  A protocol for a randomised clinical trial of the effect of providing feedback on inhaler technique and adherence from an electronic device in patients with poorly controlled severe asthma , 2016, BMJ Open.

[31]  S. Hurd,et al.  GINA guidelines on asthma and beyond * , 2007, Allergy.

[32]  Tim Usherwood,et al.  Inhaler reminders improve adherence with controller treatment in primary care patients with asthma. , 2014, The Journal of allergy and clinical immunology.