The custom-made titanium orbital floor prosthesis in reconstruction for orbital floor fractures.

This is the author’s version of a work that was accepted for publication in Journal of Oral and Maxillofacial Surgery. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published at: http://dx.doi.org/10.1016/S0266435602002498

[1]  H S Park,et al.  Various Applications of Titanium Mesh Screen Implant to Orbital Wall Fractures , 2001, The Journal of craniofacial surgery.

[2]  K F Moos,et al.  The use of silastic as an orbital implant for reconstruction of orbital wall defects: review of 311 cases treated over 20 years. , 1995, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[3]  R Bibb,et al.  The application of computer aided product development techniques in medical modelling topic: rehabilitation and prostheses. , 2000, Biomedical sciences instrumentation.

[4]  K Aitasalo,et al.  Reconstruction of orbital floor fractures using bioactive glass. , 2000, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.

[5]  P. Whitfield,et al.  Isolated orbital blowout fractures: survey and review. , 2000, The British journal of oral & maxillofacial surgery.

[6]  G. Undt,et al.  Colour stereolithography for planning complex maxillofacial tumour surgery. , 1998, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.

[7]  A. Dietz,et al.  Effectiveness of a new perforated 0.15 mm poly-p-dioxanon-foil versus titanium-dynamic mesh in reconstruction of the orbital floor. , 2001, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.

[8]  D. Holck,et al.  Benefits of stereolithography in orbital reconstruction. , 1999, Ophthalmology.

[9]  P. Sharrock,et al.  Stereolithographic models derived from X-ray computed tomography - Reproduction accuracy , 1997, Surgical and Radiologic Anatomy.

[10]  P. Rubin,et al.  Orbital reconstruction using porous polyethylene sheets. , 1994, Ophthalmology.

[11]  A. Dietz,et al.  Effectiveness of a new perforated 0.15 mm poly-p-dioxanon-foil versus titanium-dynamic mesh in reconstruction of the orbital floor. , 2001, Journal of maxillofacial surgery.

[12]  Martin Groten,et al.  Orbital Reconstruction with Individually Copy‐Milled Ceramic Implants , 1997, Plastic and reconstructive surgery.

[13]  P. D'urso,et al.  Stereolithographic biomodelling in cranio-maxillofacial surgery: a prospective trial. , 1999, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.

[14]  C. Lindqvist,et al.  Reconstruction of orbital floor with polydioxanone plate. , 1991, International journal of oral and maxillofacial surgery.

[15]  C. Kermer,et al.  Preoperative stereolithographic model planning for primary reconstruction in craniomaxillofacial trauma surgery. , 1998, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.