Continuous measurement of left ventricular volume in animals and humans by conductance catheter.

An eight-electrode conductance catheter previously developed by us and used to determine stroke volume in dogs was applied in human beings and dogs to measure absolute left ventricular volume quantitatively. For calibration we developed the formula V(t) = (1/alpha)(L2/sigma b)G(t) - Vc, where V(t) is time-varying left ventricular volume, alpha is a dimensionless constant, L is the electrode separation, sigma b is the conductivity of blood obtained by a sampling cuvette, and G(t) is the measured conductance within the left ventricular cavity. Vc is a correction term caused by the parallel conductance of structures surrounding the cavity and is measured in two ways. The first method, applicable in the anesthetized animal, consists of temporary reduction of volume to zero by suction. The second method uses a transient change in sigma b by injection of a small bolus of hypertonic saline (dogs) or 10 ml of cold glucose (humans) into the pulmonary artery. The validity of the formula was previously established for the isolated postmortem canine heart. The predicted linearity, slope constant alpha, and accuracy of Vc for the left ventricle in vivo were investigated by comparing the conductance volume data with results from independent methods: electromagnetic blood flow measurement for stroke volume and indicator dilution technique for ejection fraction (dogs), thermal dilution for cardiac output (12 patients), and single-plane cineventriculography for V(t) (five patients). In all comparisons, linear regression showed high correlation (from r = .82 [n = 46] to r = .988 [n = 20]) while alpha, with one exception, ranged from 0.75 to 1.07 and the error in Vc ranged from 0.5% to 16.5% (mean 7%). After positioning of the catheter, no arrhythmias were observed. It is concluded that the conductance catheter provides a reliable and simple method to measure left ventricular volume, giving an on-line, time-varying signal that is easily calibrated. Together with left ventricular pressure obtained through the catheter lumen, the instrument may be used for instantaneous display of pressure-volume loops to facilitate assessment of left ventricular pump performance.

[1]  Hiroyukisuga,et al.  Instantaneous Pressure-Volume Relationships and Their Ratio in the Excised, Supported Canine Left Ventricle , 1974 .

[2]  R. Lasser,et al.  Reflex Circulatory Effects Elicited by Hypertonic and Hypotonic Solutions Injected into Femoral and Brachial Arteries of Dogs , 1960, Circulation research.

[3]  E. T. van der Velde,et al.  Continuous stroke volume and cardiac output from intra-ventricular dimensions obtained with impedance catheter. , 1981, Cardiovascular research.

[4]  Jan Baan,et al.  Computation of the Input Impedances of a Catheter for Cardiac Volumetry , 1984, IEEE Transactions on Biomedical Engineering.

[5]  L A Geddes,et al.  The development and calibration of a method for the continuous measurement of stroke-volume in the experimental animal. , 1966, Japanese heart journal.

[6]  I. Velasco,et al.  Hyperosmotic NaCl and severe hemorrhagic shock. , 1980, The American journal of physiology.

[7]  P H Heintzen,et al.  Analysis of left and right ventricular size and shape, as determined from human casts. Description of the method and its validation. , 1978, European journal of cardiology.

[8]  G. Schuler,et al.  The Linearity of the End‐systolic Pressure‐Volume Relationship in Man and Its Sensitivity for Assessment of Left Ventricular Function , 1981, Circulation.

[9]  L. Geddes,et al.  Cardiac output using an electrically calibrated flow-through conductivity cell. , 1974, Journal of applied physiology.

[10]  J. Nyboer,et al.  IMPEDANCE CARDIOGRAMS AND DIFFERENTIATED‐IMPEDANCE CARDIOGRAMS‐THE ELECTRICAL IMPEDANCE CHANGES OF THE HEART IN RELATION TO ELECTROCARDIOGRAMS AND HEART SOUNDS * , 1970 .

[11]  R. Helfant,et al.  Nuclear cardiology. I. Radionuclide angiographic assessment of left ventricular contraction: uses, limitations and future directions. , 1980, The American journal of cardiology.

[12]  R. F. Rushmer,et al.  Intracardiac impedance plethysmography. , 1953, The American journal of physiology.

[13]  S. Rush,et al.  Resistivity of Body Tissues at Low Frequencies , 1963, Circulation research.

[14]  G V Heller,et al.  Instantaneous measurement of left and right ventricular stroke volume and pressure-volume relationships with an impedance catheter. , 1984, Circulation.

[15]  Helmut Hinghofer-Szalkay,et al.  Cardiovascular system dynamics : models and measurements , 1982 .

[16]  G. J. Crystal,et al.  Small vessel and total coronary blood volume during intracoronary adenosine. , 1981, The American journal of physiology.

[17]  R. Patterson,et al.  Development and evaluation of an impedance cardiac output system. , 1966, Aerospace medicine.

[18]  G. Diamond,et al.  Thermodilution cardiac output determination with a single flow-directed catheter. , 1972, American heart journal.

[19]  B. Brundage,et al.  Ventricular function curves from the cardiac response to angiographic contrast: a sensitive detector of ventricular dysfunction in coronary artery disease. , 1974, American heart journal.

[20]  W. Penfield THE TREATMENT OF SEVERE AND PROGRESSIVE HEMORRHAGE BY INTRAVENOUS INJECTIONS , 1919 .

[21]  E. Yellin,et al.  The Influence of Left Ventricular Filling on Postextrasystolic Potentiation in the Dog Heart , 1979, Circulation research.

[22]  W Grossman,et al.  Contractile State of the Left Ventricle in Man as Evaluated from End‐systolic Pressure‐Volume Relations , 1977, Circulation.

[23]  W Grossman,et al.  Estimation of left ventricular volumes in man from biplane cineangiograms filmed in oblique projections. , 1978, The American journal of cardiology.

[24]  Inlet and Intrachamber Concentration Distributions in Tracer Studies of the Canine Central Circulation and Their Relation to the Isotope Dilution Residue Function , 1980, Circulation research.

[25]  W. Grossman,et al.  Determinants of Ventricular Function in Pressure-Overload Hypertrophy in Man , 1979, Circulation.