Mitigation Of Voltage Fluctuations Due To 3P Oscillations Of Wind Farm Using Series Controller

Rapid increase in demand for power, depletion of conventional energy sources and their adverse effects on environment is making power engineers to look for alternatives for power generation. Power generation through wind gained more popularity across the world due to technology advancements and low installation costs compared to solar and other sources of renewable energy. Grid integration of wind turbines has negative impact on grid operation due to random nature of wind, wind shear and tower shadow effects. Thus, the wind turbines are fluctuating power sources that influence power quality in distribution system. This paper presents a series controller for blocking these disturbances and maintaining the power quality within the acceptable limits defined by industry standards. The simulation results, carried out by using MATLAB/SIMULINK show the impact of these disturbances on the grid. The proposed series controller is found to be an effective tool in blocking disturbances at the point of common coupling and thereby maintaining the power quality.

[1]  W. T. Norris,et al.  Flicker analysis and methods for electric arc furnace flicker (EAF) mitigation (a survey) , 2001, 2001 IEEE Porto Power Tech Proceedings (Cat. No.01EX502).

[2]  Liangzhong Yao,et al.  Integrating Wind Farm to the Grid Using Hybrid Multiterminal HVDC Technology , 2011, IEEE Transactions on Industry Applications.

[3]  Trevor Pryor,et al.  Power quality issues in a wind turbine driven induction generator and diesel hybrid autonomous grid , 2001 .

[4]  J. G. Slootweg,et al.  The impact of large scale wind power generation on power system oscillations , 2003 .

[5]  Zhe Chen,et al.  Flicker Mitigation by Active Power Control of Variable-Speed Wind Turbines With Full-Scale Back-to-Back Power Converters , 2009, IEEE Transactions on Energy Conversion.

[6]  Stavros A. Papathanassiou,et al.  Investigation of the flicker emission by grid connected wind turbines , 1998, 8th International Conference on Harmonics and Quality of Power. Proceedings (Cat. No.98EX227).

[7]  Jyh-Shing Roger Jang,et al.  ANFIS: adaptive-network-based fuzzy inference system , 1993, IEEE Trans. Syst. Man Cybern..

[8]  S. P. Dubey,et al.  Fuzzy logic controlled shunt active power filter for reactive power compensation and harmonic elimination , 2011, 2011 2nd International Conference on Computer and Communication Technology (ICCCT-2011).

[9]  Goran Strbac,et al.  Application of STATCOMs to wind farms , 1998 .

[10]  P.W. Lehn,et al.  Simulation Model of Wind Turbine 3p Torque Oscillations due to Wind Shear and Tower Shadow , 2006, 2006 IEEE PES Power Systems Conference and Exposition.

[11]  Agis Papantoniou,et al.  Simulation of FACTS for wind farm applications , 1997 .

[12]  K. Al-Haddad,et al.  Comparison of fuzzy logic and proportional integral controller of voltage source active filter compensating current harmonics and power factor , 2004, 2004 IEEE International Conference on Industrial Technology, 2004. IEEE ICIT '04..

[13]  Mutsuo Nakaoka,et al.  An advanced active power filter with adaptive neural network based harmonic detection scheme , 2001, 2001 IEEE 32nd Annual Power Electronics Specialists Conference (IEEE Cat. No.01CH37230).

[14]  Hao Ying,et al.  Fuzzy Control and Modeling: Analytical Foundations and Applications , 2000 .

[15]  Yoshikazu Fukuyama,et al.  Verification of cooperative control method for voltage control equipment on distribution network simulator considering interconnection of wind power generators , 2002, IEEE/PES Transmission and Distribution Conference and Exhibition.

[16]  P. Marino,et al.  Improved and extended DG capability in voltage regulation by reactive and active power , 2007, 2007 International Conference on Power Engineering, Energy and Electrical Drives.

[17]  J. R. Vazquez,et al.  Active power filter control using neural network technologies , 2003 .

[18]  J. E. Hill A practical example of the use of distribution static compensator (D-STATCOM) to reduce voltage fluctuations , 1997 .

[19]  S. P. Dubey,et al.  Neural network based shunt active filter for harmonic and reactive power compensation under non-ideal mains voltage , 2010, 2010 5th IEEE Conference on Industrial Electronics and Applications.

[20]  Asheesh K. Singh,et al.  A simple fuzzy logic based robust active power filter for harmonics minimization under random load variation , 2007 .

[21]  A. Larsson,et al.  Flicker Emission of Wind Turbines during Continuous Operation , 2002, IEEE Power Engineering Review.

[22]  M.H.J. Bollen,et al.  Mitigation of voltage dips through distributed generation systems , 2003, IEEE Transactions on Industry Applications.

[23]  T. Larsson,et al.  STATCOM, an efficient means for flicker mitigation , 1999, IEEE Power Engineering Society. 1999 Winter Meeting (Cat. No.99CH36233).

[24]  M. G. Ioannides,et al.  Assessment of wind turbines impact on the power quality of autonomous weak grids , 1998, 8th International Conference on Harmonics and Quality of Power. Proceedings (Cat. No.98EX227).

[25]  P.N. Enjeti,et al.  A fast detection algorithm suitable for mitigation of numerous power quality disturbances , 2001, Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248).