A computational tool to support pre-operative planning of stentless aortic valve implant.

In some cases of aortic valve leaflet disease, the implant of a stentless biological prosthesis represents an excellent option for aortic valve replacement (AVR). In particular, if compared to more classical surgical approaches, it provides a more physiological hemodynamic performance and a minor trombogeneticity avoiding the use of anticoagulants. The clinical outcomes of AVR are strongly dependent on an appropriate choice of both prosthesis size and replacement technique, which are, at present, strictly related to surgeon's experience and skill. Therefore, also this treatment, like most reconstructive procedures in cardiac surgery, remains "more art than science". Nowadays computational methodologies represent a useful tool both to investigate the aortic valve behavior, in physiologic and pathologic conditions and to reproduce virtual post-operative scenarios. The present study aims at supporting the AVR procedure planning through a patient-specific Finite Element Analysis (FEA) of stentless valve implantation. Firstly, we perform FEA to simulate the prosthesis placement inside the patient-specific aortic root; then, we reproduce, again by means of FEA, the diastolic closure of the valve to evaluate both the coaptation and the stress/strain state. The simulation results prove that both the valve size and the anatomical asymmetry of the Valsalva sinuses affect the prosthesis placement procedure.

[1]  William M L Neethling,et al.  Homograft aortic valve replacement--the experience of one unit. , 2004, Heart, lung & circulation.

[2]  J. Gummert,et al.  Quality of Life after Mechanical vs. Biological Aortic Valve Replacement , 2005, Asian cardiovascular & thoracic annals.

[3]  D R Boughner,et al.  The bovine pericardial xenograft: I. Effect of fixation in aldehydes without constraint on the tensile viscoelastic properties of bovine pericardium. , 1989, Journal of biomedical materials research.

[4]  F Auricchio,et al.  Finite element analysis of aortic root dilation: a new procedure to reproduce pathology based on experimental data , 2011, Computer methods in biomechanics and biomedical engineering.

[5]  Erich Wintermantel,et al.  Finite Element Investigation of Stentless Pericardial Aortic Valves: Relevance of Leaflet Geometry , 2010, Annals of Biomedical Engineering.

[6]  A. Redaelli,et al.  Dynamic finite element analysis of the aortic root from MRI-derived parameters. , 2010, Medical engineering & physics.

[7]  Michel R Labrosse,et al.  Geometric modeling of functional trileaflet aortic valves: development and clinical applications. , 2006, Journal of biomechanics.

[8]  D. Mozaffarian,et al.  Executive summary: heart disease and stroke statistics--2010 update: a report from the American Heart Association. , 2010, Circulation.

[9]  Harlan M Krumholz,et al.  Quality of life after aortic valve replacement with tissue and mechanical implants. , 2004, The Journal of thoracic and cardiovascular surgery.

[10]  J. Lowe,et al.  Long-term outcome after biologic versus mechanical aortic valve replacement in 841 patients. , 1999, The Journal of thoracic and cardiovascular surgery.

[11]  Alexander Kulik,et al.  Mechanical versus bioprosthetic valve replacement in middle-aged patients. , 2006, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[12]  C. Vosa,et al.  Aortic valve replacement: a prospective randomized evaluation of mechanical versus biological valves in patients ages 55 to 70 years. , 2009, Journal of the American College of Cardiology.

[13]  Lee Jm,et al.  The bovine pericardial xenograft: I. Effect of fixation in aldehydes without constraint on the tensile viscoelastic properties of bovine pericardium , 1989 .

[14]  C. Yap,et al.  Allograft aortic valve replacement in the adult: a review. , 2004, Heart, lung & circulation.

[15]  J P Remadi,et al.  Preliminary results of 130 aortic valve replacements with a new mechanical bileaflet prosthesis: the Edwards MIRA valve. , 2003, Interactive cardiovascular and thoracic surgery.

[16]  Ugolino Livi,et al.  Results of aortic valve replacement with a new supra-annular pericardial stented bioprosthesis. , 2006, The Annals of thoracic surgery.

[17]  Alberto Redaelli,et al.  Aortic root performance after valve sparing procedure: a comparative finite element analysis. , 2009, Medical engineering & physics.

[18]  Wei Sun,et al.  Simulated elliptical bioprosthetic valve deformation: implications for asymmetric transcatheter valve deployment. , 2010, Journal of biomechanics.

[19]  T. David,et al.  Aortic valve sparing operations. , 2002, The Annals of thoracic surgery.

[20]  Pasquale Totaro,et al.  Carpentier-Edwards PERIMOUNT Magna bioprosthesis: a stented valve with stentless performance? , 2005, The Journal of thoracic and cardiovascular surgery.

[21]  D. Mozaffarian,et al.  Heart disease and stroke statistics--2010 update: a report from the American Heart Association. , 2010, Circulation.

[22]  Thierry Carrel,et al.  The Sorin Freedom SOLO stentless aortic valve: technique of implantation and operative results in 109 patients. , 2010, The Journal of thoracic and cardiovascular surgery.

[23]  Guido Gerig,et al.  User-guided 3D active contour segmentation of anatomical structures: Significantly improved efficiency and reliability , 2006, NeuroImage.

[24]  Demetri Terzopoulos,et al.  Snakes: Active contour models , 2004, International Journal of Computer Vision.

[25]  E. A. Trowbridge,et al.  The mechanical response of glutaraldehyde-fixed bovine pericardium to uniaxial load , 1985 .

[26]  Mathieu Pernot,et al.  Freedom SOLO valve: early- and intermediate-term results of a single centre's first 100 cases. , 2011, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[27]  Marco Solinas,et al.  Technique for implant of the stentless aortic valve Freedom Solo. , 2007, Multimedia manual of cardiothoracic surgery : MMCTS.

[28]  Wolfgang Konertz,et al.  Continuous Suture Technique for Freedom Stentless Valve: Reduced Crossclamp Time , 2006, Asian cardiovascular & thoracic annals.

[29]  T. David,et al.  Aortic valve sparing operations: basic concepts. , 2004, International journal of cardiology.

[30]  M. Yacoub,et al.  Remodeling of the aortic valve anulus. , 1993, The Journal of thoracic and cardiovascular surgery.

[31]  A. Ranga,et al.  A Compliant Dynamic FEA Model of the Aortic Valve , 2007 .

[32]  K S Kunzelman,et al.  Mechanisms of aortic valve incompetence: finite-element modeling of Marfan syndrome. , 2001, The Journal of thoracic and cardiovascular surgery.

[33]  O. Yeoh Some Forms of the Strain Energy Function for Rubber , 1993 .

[34]  Michel R Labrosse,et al.  Aortic root dilatation may alter the dimensions of the valve leaflets. , 2005, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.