Impedance Properties of Metal Electrodes for Chronic Recording from Mammalian Nerves

Over the last few years methods have been developed for recording chronically from mammalian nerves with implanted electrodes contained in silastic cuffs. The impedance of the electrodes and the changes that take place over time were studied. Platinum-iridium electrodes remain stable over long periods of time, whereas the impedance of silver wire electrodes increases and eventually the silver fractures. The impedance at low frequencies (e.g., 10 Hz) provides a measure of the capacitance of the metal electrodes, whereas the impedance at higher frequencies (1 kHz) mainly measures the resistance of the tissue filling the cuff. Increases in resistance due to growth of connective tissue around intact nerves have been studied as well as changes in resistance after cutting a nerve. Impedance measurements provide a useful way to follow the properties of electrodes and nerves in basic neuroscientific research and in future clinical applications of these chronic recording methods.

[1]  D. Robinson,et al.  The electrical properties of metal microelectrodes , 1968 .

[2]  M Salcman,et al.  Design, fabrication, and in vivo behavior of chronic recording intracortical microelectrodes. , 1973, IEEE transactions on bio-medical engineering.

[3]  T. Ducker,et al.  Experimental improvements in the use of Silastic cuff for peripheral nerve repair. , 1968, Journal of neurosurgery.

[4]  R. Stein,et al.  Regeneration Electrode Units: Implants for Recording from Single Peripheral Nerve Fibers in Freely Moving Animals , 1974, Science.

[5]  B. Cragg,et al.  Changes in conduction velocity and fibre size proximal to peripheral nerve lesions , 1961, The Journal of physiology.

[6]  C J De Luca,et al.  Voluntary nerve signals from severed mammalian nerves: long-term recordings. , 1976, Science.

[7]  W. Olson,et al.  Selective damage of large diameter peripheral nerve fibers by compression: An application of Laplace's Law , 1975, Experimental Neurology.

[8]  Anthony M. Dymond,et al.  Characteristics of the Metal-Tissue Interface of Stimulation Electrodes , 1976, IEEE Transactions on Biomedical Engineering.

[9]  Hayes Gj,et al.  Experimental improvements in the use of Silastic cuff for peripheral nerve repair. , 1968 .

[10]  W. B. Marks,et al.  Long-Term Peripheral Nerve Activity During Behavior in the Rabbit , 1976 .

[11]  I. Tasaki,et al.  A NEW MEASUREMENT OF ACTION CURRENTS DEVELOPED BY SINGLE NODES OF RANVIER. , 1964, Journal of neurophysiology.

[12]  R. Stein,et al.  Stable long-term recordings from cat peripheral nerves , 1977, Brain Research.

[13]  V. Mooney,et al.  Osseous attachment to vitreous carbons. , 1973, Journal of biomedical materials research.

[14]  R. Stein,et al.  Principles Underlying New Methods for Chronic Neural Recording , 1975, Canadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques.