The Forced-Commutated Inverter as a Regenerative Rectifier

The application of a three-phase 120°-gated forced commutated thyristor inverter as a regenerative rectification circuit is discussed. The circuit has the ability to accept or deliver dc current without change of nominal dc voltage magnitude or polarity and also has the capability to instantaneously change from ``motoring'' to ``generating'' and vice versa. An analysis of the circuit is undertaken to provide both the current waveforms and the regulation characteristic, which are compared with those of a conventional rectifier. Theoretical results are compared with those obtained from a laboratory working prototype.

[1]  Thomas A. Lipo,et al.  Analysis and Comparison of Two Types of Square-Wave Inverter Drives , 1975, IEEE transactions on industry applications.

[2]  I. K. Dortort Extended regulation curves for 6-phase double-way and double-wye rectifiers , 1953, Transactions of the American Institute of Electrical Engineers, Part I: Communication and Electronics.

[3]  James W. A. Wilson Double three-phase power conversion systems , 1971 .

[4]  R. G. Schieman,et al.  Solid-state control of electric drives , 1974 .

[5]  L. E. Jensen,et al.  Regulator curves and transient currents of double-way and double-wye rectifiers , 1955, Transactions of the American Institute of Electrical Engineers, Part I: Communication and Electronics.

[6]  J. V. Kresser,et al.  Influence of A-C reactance on voltage regulation of 6-phase rectifiers , 1953, Transactions of the American Institute of Electrical Engineers, Part I: Communication and Electronics.