Performance expectations for a Tomography System using cosmic ray muons and micro pattern gas detectors for the detection of nuclear contraband

We present results from a detailed GEANT4 simulation of a proposed Muon Tomography System that employs compact Micro Pattern Gas Detectors with high spatial resolution. A basic Point-Of-Closest-Approach algorithm is applied to reconstructed muon tracks for forming 3D tomographic images of interrogated targets. Criteria for discriminating materials by Z and discrimination power achieved by the technique for simple scenarios are discussed for different integration times. The simulation shows that Muon Tomography can clearly distinguish high-Z material from low-Z and medium-Z material. We have studied various systematic effects that affect the performance of the MT and the discrimination power. The implications of the simulation results for the planned development of a prototype MT station are discussed.