Improved Dose Regimen in Pediatric PET

PET image quality depends strongly on patient weight and habitus, decreasing for increasing weight and body mass index. Common adult injection rules prescribe either a dose proportional to weight or a fixed dose. In light patients, image quality may improve for decreasing weight more than by inverse proportion. If better quality than in average-adult studies does not justify the associated dose burden, attractive options are to reduce scan time, reduce dose, or any combination of the 2. The objective of this study was to determine quantitative injection rules for pediatric PET allowing clinical implementation of these trade-offs. Methods: Literature methods combining phantom with clinical data were followed to derive patient-specific noise-equivalent count rate density (NECRD) curves as a function of injected dose. From these, it was possible to estimate retrospectively for each patient the scan time that would have been sufficient for the same NECRD as in a 70-kg reference adult; the reduced dose sufficient for constant NECRD and scan time; and a general relationship among scan time, dose, and NECRD. Correlation to the patient statistic giving highest correlation, which was found to be weight, provided rules applicable prospectively. Data from 73 patients (weight, 11.5–91.4 kg; mean, 45.4 kg) were acquired and analyzed. Results: Following the clinical injection rule, which was proportional to weight, the NECRD increased linearly with decreasing weight. The expression exp[0.019 × (weight [kg] − 70)] for the time reduction possible with the current dose at constant NECRD correlated well with data (R2 = 0.86). The dose (in MBq) necessary for constant NECRD that should be injected 60 min before imaging is predicted well by 14.8 × exp[0.046 × weight (kg)] (R2 = 0.88) with the current scan time. A more complex expression to convert NECRD in whole or part to both dose and time savings was also derived. Comparison to common pediatric injection rules showed reasonable agreement with Clark's rule, albeit not at all weights. Conclusion: Results suggest that pediatric PET of constant image quality (in an NECRD sense) can be performed with time or dose savings, up to 50% for the lightest patients (10–20 kg).

[1]  E. Boyd,et al.  The Growth of the Surface Area of the Human Body. , 1935 .

[2]  R. Mosteller Simplified calculation of body-surface area. , 1987, The New England journal of medicine.

[3]  W. Segars,et al.  Study of the efficacy of respiratory gating in myocardial SPECT using the new 4-D NCAT phantom , 2001 .

[4]  T D Cradduck,et al.  National electrical manufacturers association , 1983, Journal of the A.I.E.E..

[5]  G. Schwartz,et al.  Geometric method for measuring body surface area: a height-weight formula validated in infants, children, and adults. , 1978, The Journal of pediatrics.

[6]  Mosteller Rd Simplified Calculation of Body-Surface Area , 1987 .

[7]  Deb Miller Rn Bs Cnor Foundations of Nursing , 2003 .

[8]  O. Mawlawi,et al.  Performance characteristics of a newly developed PET/CT scanner using NEMA standards in 2D and 3D modes. , 2004, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[9]  R. Badawi,et al.  NEC: some coincidences are more equivalent than others. , 2005, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[10]  D. DuBois,et al.  A formula to estimate the approximate surface area if height and weight be known , 1989 .

[11]  D. Brenner,et al.  Cancer risks from diagnostic radiology. , 2008, The British journal of radiology.

[12]  Charles B. Sampson,et al.  Textbook of radiopharmacy : theory and practice , 1990 .

[13]  Tim Mulnix,et al.  PET performance measurements for an LSO-based combined PET/CT scanner using the National Electrical Manufacturers Association NU 2-2001 standard. , 2004, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[14]  E. Hoffman,et al.  Measuring PET scanner sensitivity: relating countrates to image signal-to-noise ratios using noise equivalents counts , 1990 .

[15]  Sue C. Kaste,et al.  The ALARA (as low as reasonably achievable) concept in pediatric interventional and fluoroscopic imaging: striving to keep radiation doses as low as possible during fluoroscopy of pediatric patients—a white paper executive summary , 2006, Pediatric Radiology.

[16]  Suleman Surti,et al.  Imaging characteristics of a 3-dimensional GSO whole-body PET camera. , 2004, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[17]  Roberta Matheoud,et al.  Performance characteristics obtained for a new 3-dimensional lutetium oxyorthosilicate-based whole-body PET/CT scanner with the National Electrical Manufacturers Association NU 2-2001 standard. , 2005, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[18]  K. Koral,et al.  Accurate dosimetry in 131I radionuclide therapy using patient-specific, 3-dimensional methods for SPECT reconstruction and absorbed dose calculation. , 2005, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[19]  K. Gulenchyn,et al.  6-l-18F-Fluorodihydroxyphenylalanine PET in Neuroendocrine Tumors: Basic Aspects and Emerging Clinical Applications* , 2008, Journal of Nuclear Medicine.

[20]  Christian Vanhove,et al.  Optimal dose of 18F-FDG required for whole-body PET using an LSO PET camera , 2003, European Journal of Nuclear Medicine and Molecular Imaging.

[21]  Carole Lartizien,et al.  Optimization of injected dose based on noise equivalent count rates for 2- and 3-dimensional whole-body PET. , 2002, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[22]  K. Strauss,et al.  The Image Gently campaign: working together to change practice. , 2008, AJR. American journal of roentgenology.

[23]  E. Gehan,et al.  Estimation of human body surface area from height and weight. , 1970, Cancer chemotherapy reports.

[24]  J A CHURCHILL,et al.  Posology in Infants and Children , 1964, Developmental medicine and child neurology.

[25]  Jack Valentin,et al.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103. , 2007, Annals of the ICRP.

[26]  Stefan Eberl,et al.  Optimizing injected dose in clinical PET by accurately modeling the counting-rate response functions specific to individual patient scans. , 2005, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.