Fuzzy logic approach for transformer remnant life prediction and asset management decision

The quality of insulation system within power transformer reflects the overall health condition of the asset. A timely and reliable maintenance decision along with the remaining operational life estimation of the asset can be identified through the measurements of some parameters reflecting the degradation rate of the transformer dielectric insulation. However, the process is not always straightforward due to the complexity of the insulation structure and degradation process. This paper proposes a new fuzzy logic approach to provide a proper asset management decision and predict the remaining operational life of a power transformer based on some insulating oil tests. The developed fuzzy logic model is validated through field data collected for various transformers of preknown health condition and life span. Results show that the proposed model is reliable and can be facilitated to provide a timely asset management decision with less reliance on expert personnel.

[1]  Wang Fan,et al.  An approach to power transformer asset management using health index , 2009, IEEE Electrical Insulation Magazine.

[2]  A. Abu-Siada,et al.  A review on chemical diagnosis techniques for transformer paper insulation degradation , 2013, 2013 Australasian Universities Power Engineering Conference (AUPEC).

[3]  Peter H. F. Morshuis,et al.  Life-data analysis for condition assessment of high-voltage assets , 2015, IEEE Electrical Insulation Magazine.

[4]  S. Okabe,et al.  Aging effect on electrical characteristics of insulating oil in field transformer , 2009, IEEE Transactions on Dielectrics and Electrical Insulation.

[5]  Hui Ma,et al.  An Updated Model to Determine the Life Remaining of Transformer Insulation , 2015, IEEE Transactions on Power Delivery.

[6]  M. Ali,et al.  Degradation of cellulosic insulation in power transformers .4. Effects of ageing on the tensile strength of paper , 2000 .

[7]  L. Cheim,et al.  Furan analysis for liquid power transformers , 2012, IEEE Electrical Insulation Magazine.

[8]  A. Abu-Siada,et al.  A Novel Fuzzy-Logic Approach for Furan Estimation in Transformer Oil , 2012, IEEE Transactions on Power Delivery.

[9]  R.A. Jongen,et al.  Application of statistical methods for making maintenance decisions within power utilities , 2006, IEEE Electrical Insulation Magazine.

[10]  M. M. A. Salama,et al.  Calculation of a Health Index for Oil-Immersed Transformers Rated Under 69 kV Using Fuzzy Logic , 2012, IEEE Transactions on Power Delivery.

[11]  Zhixin Mao,et al.  Detection of dissolved gas in oil–insulated electrical apparatus by photoacoustic spectroscopy , 2015, IEEE Electrical Insulation Magazine.

[12]  Syed Islam,et al.  Fuzzy logic approach in power transformers management and decision making , 2014, IEEE Transactions on Dielectrics and Electrical Insulation.

[13]  A. Abu-Siada,et al.  A new fuzzy logic approach for consistent interpretation of dissolved gas-in-oil analysis , 2013, IEEE Transactions on Dielectrics and Electrical Insulation.

[14]  A. Abu-Siada,et al.  A review of dissolved gas analysis measurement and interpretation techniques , 2014, IEEE Electrical Insulation Magazine.

[15]  S. M. Islam,et al.  Significance of cellulose power transformer condition assessment , 2011, IEEE Transactions on Dielectrics and Electrical Insulation.

[16]  K. D. Srivastava,et al.  Review of condition assessment of power transformers in service , 2002 .

[17]  P. Purkait,et al.  Investigation of an expert system for the condition assessment of transformer insulation based on dielectric response measurements , 2004, IEEE Transactions on Power Delivery.

[18]  D. Linhjell,et al.  Aging of oil-impregnated paper in power transformers , 2004, IEEE Transactions on Power Delivery.

[19]  Z. Qian,et al.  Fuzzy synthetic method for life assessment of power transformer , 2004 .

[20]  Daniel Martin,et al.  Determining water in transformer paper insulation: analyzing aging transformers , 2015, IEEE Electrical Insulation Magazine.

[21]  M. Ali,et al.  Degradation of cellulosic insulation in power transformers. Part 2: formation of furan products in insulating oil , 2000 .

[22]  A. Abu-Siada,et al.  A new technique to measure interfacial tension of transformer oil using UV-Vis spectroscopy , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.

[23]  A. Abu-Siada,et al.  A new approach to identify power transformer criticality and asset management decision based on dissolved gas-in-oil analysis , 2012, IEEE Transactions on Dielectrics and Electrical Insulation.

[24]  Daniel Martin,et al.  The effect of acid accumulation in power-transformer oil on the aging rate of paper insulation , 2014, IEEE Electrical Insulation Magazine.

[25]  N. Lelekakis,et al.  Measuring Paper Water Content of Transformers: A New Approach Using Cellulose Isotherms in Nonequilibrium Conditions , 2013, IEEE Transactions on Power Delivery.