Analysis and modeling of a proportional directional valve with nonlinear solenoid

To explain the influence of the nonlinear characteristic of a proportional directional valve with double solenoids, a dynamic model with a nonlinear performance in current–force–displacement of double solenoids proportional valve is presented. Despite the analyzing of nonlinear characteristic of the solenoids, the valve spool modeling, the orifice area and the dynamic model of the valve are also presented. The simulation model is set in MATLAB and a test rig is built for the dynamic performance test. At last, the comparison in sine wave and dynamic response of the simulation and the experiments are made. A big distortion occurs near zero spool position because the nonlinear characteristic is mainly manifested when the solenoid current is small. And it is mainly induced by the nonlinear characteristic of the solenoids and the direction switch motion of spool. The output in simulation is almost coincided with that of experimental result. That means the proposed modeling method of solenoids and valve is valid and effective. Some advanced control theories and methods can be applied simultaneously.

[1]  N. D. Vaughan,et al.  The Modeling and Simulation of a Proportional Solenoid Valve , 1996 .

[2]  J. Watton,et al.  Dynamic analysis of proportional solenoid controlled piloted relief valve by bondgraph , 2005, Simul. Model. Pract. Theory.

[3]  Wang Haiying Spool displacement control system of proportional valve based on digital observer , 2007 .

[4]  Riccardo Amirante,et al.  Flow forces analysis of an open center hydraulic directional control valve sliding spool , 2006 .

[5]  Antonio Lippolis,et al.  Three-Dimensional Analysis of Flow Forces on Directional Control Valves , 2003 .

[6]  V. J. De Negri,et al.  Modeling and Analysis of an Auto- Adjustable Stroke End Cushioning Device for Hydraulic Cylinders , 2005 .

[7]  Ali Ghaffari,et al.  Modeling and identification of a solenoid valve for PWM control applications , 2009 .

[8]  Wei Li,et al.  PID Parameters Tuning of Proportional Directional Valve Based on Multiple Orthogonal Experiments Method: Method and Experiments , 2013 .

[9]  Bruce H. Wilson,et al.  Unified modeling and analysis of a proportional valve , 2006, J. Frankl. Inst..

[10]  B. Knorr,et al.  Multi-domain modeling and simulation of a linear actuation system , 2003, Proceedings of the 2003 IEEE International Workshop on Behavioral Modeling and Simulation.

[11]  Hai Yang Wang,et al.  A Spool Displacement Control System of Proportional Valve Based on Digital Observer , 2010 .

[12]  Saeid Habibi,et al.  Effect of Controller in Reducing Steady-State Error due to Flow and Force Disturbances in the Electrohydraulic Actuator System , 2004 .

[13]  Xiangyang Xu,et al.  Multi-domain modeling and simulation of proportional solenoid valve , 2011 .

[14]  C R Gentle,et al.  A parsimonious model for the proportional control valve , 2001 .