Use of Laser Light Scatter Signals to Study the Effect of a Direct-Current Biased Mesh Screen in a Spray Chamber on Aerosols Generated for Use in Atomic Spectroscopy

A new method that relies on tertiary aerosol laser light scatter signals to alleviate the NaCl chemical matrix effect in inductively coupled plasma atomic emission spectroscopy (ICP-AES) is introduced. The method involves monitoring the laser light scatter signal from the entire tertiary aerosol with a line-shaped laser beam and the plasma off. In this work, the tertiary aerosol laser scatter signal was measured to increase nonlinearly with NaCl concentration. The source of the increased scatter signal is described as originating from Coulomb fission events that droplets with net charge experience while inside the spray chamber. Each droplet in the secondary aerosol that undergoes Coulomb fission introduces ∼ 20 progeny droplets into the aerosol stream. The introduction of progeny droplets to the aerosol stream measured by increased laser light scatter signals coincides with an increase in analyte emission, off-axis, at low viewing heights in an inductively coupled plasma, a characteristic of the easily ionized element chemical matrix effect. It is shown that a direct-current potential applied to a mesh screen positioned inside the spray chamber can coarsely control the transport of droplets with net charge through the spray chamber, by effecting their removal from the aerosol stream. With an appropriate voltage applied to the mesh, the laser scatter signal from the tertiary aerosol from a solution containing 100 mM NaCl can be made similar to the scatter signal from a solution that does not contain NaCl. Under the same conditions, calcium-ion lateral emission signal intensity contour maps in a plasma for the same two solutions become similar within the normal analytical zone in the plasma (2 mm wide, from 13 to 19 mm above the load coil).

[1]  J. V. Iribarne,et al.  On the evaporation of small ions from charged droplets , 1976 .

[2]  M. Blades,et al.  The vertical spatial characteristics of analyte emission in the inductively coupled plasma , 1981 .

[3]  G. Hieftje,et al.  Optical imaging spectrometers , 1985 .

[4]  E. Davis,et al.  Electrified droplet fission and the Rayleigh limit , 1989 .

[5]  A. Canals,et al.  Experimental Evaluation of the Nukiyama-Tanasawa Equation for Pneumatically Generated Aerosols Used in Flame Atomic Spectrometry , 1992 .

[6]  N. Dovichi,et al.  Behavior of Microscopic Liquid Droplets near A Strong Electrostatic Field: Droplet Electrospray , 1994 .

[7]  Norman N. Sesi,et al.  Studies into the interelement matrix effect in inductively coupled plasma spectrometry , 1996 .

[8]  J. Mermet,et al.  Effect of sodium during the aerosol transport and filtering in inductively coupled plasma atomic emission spectrometry , 1998 .

[9]  R. Barnes,et al.  Correction for non-spectroscopic matrix effects in inductively coupled plasma-atomic emission spectroscopy by internal standardization using spectral lines of the same analyte , 1998 .

[10]  J. Mermet Revisitation of the matrix effects in inductively coupled plasma atomic emission spectrometry: the key role of the spray chamber , 1998 .

[11]  G. Mattu,et al.  Influence of Droplets with Net Charge in Inductively Coupled Plasma Atomic Emission Spectroscopy and Implications for the Easily Ionizable Element Chemical Matrix Effect , 1999 .