Bimodal intravascular volumetric imaging combining OCT and MPI

PURPOSE Intravascular optical coherence tomography (IVOCT) is a catheter-based image modality allowing for high-resolution imaging of vessels. It is based on a fast sequential acquisition of A-scans with an axial spatial resolution in the range of 5-10 μm, that is, one order of magnitude higher than in conventional methods like intravascular ultrasound or computed tomography angiography. However, position and orientation of the catheter in patient coordinates cannot be obtained from the IVOCT measurements alone. Hence, the pose of the catheter needs to be established to correctly reconstruct the three-dimensional vessel shape. Magnetic particle imaging (MPI) is a three-dimensional tomographic, tracer-based, and radiation-free image modality providing high temporal resolution with unlimited penetration depth. Volumetric MPI images are angiographic and hence suitable to complement IVOCT as a comodality. We study simultaneous bimodal IVOCT MPI imaging with the goal of estimating the IVOCT pullback path based on the 3D MPI data. METHODS We present a setup to study and evaluate simultaneous IVOCT and MPI image acquisition of differently shaped vessel phantoms. First, the influence of the MPI tracer concentration on the optical properties required for IVOCT is analyzed. Second, using a concentration allowing for simultaneous imaging, IVOCT and MPI image data are acquired sequentially and simultaneously. Third, the luminal centerline is established from the MPI image volumes and used to estimate the catheter pullback trajectory for IVOCT image reconstruction. The image volumes are compared to the known shape of the phantoms. RESULTS We were able to identify a suitable MPI tracer concentration of 2.5 mmol/L with negligible influence on the IVOCT signal. The pullback trajectory estimated from MPI agrees well with the centerline of the phantoms. Its mean absolute error ranges from 0.27 to 0.28 mm and from 0.25 mm to 0.28 mm for sequential and simultaneous measurements, respectively. Likewise, reconstructing the shape of the vessel phantoms works well with mean absolute errors for the diameter ranging from 0.11 to 0.21 mm and from 0.06 to 0.14 mm for sequential and simultaneous measurements, respectively. CONCLUSIONS Magnetic particle imaging can be used in combination with IVOCT to estimate the catheter trajectory and the vessel shape with high precision and without ionizing radiation.

[1]  Jörn Borgert,et al.  Magnetic Particle Imaging (MPI): Experimental Quantification of Vascular Stenosis Using Stationary Stenosis Phantoms , 2017, PloS one.

[2]  Fanis G Kalatzis,et al.  A new methodology for accurate 3-dimensional coronary artery reconstruction using routine intravascular ultrasound and angiographic data: implications for widespread assessment of endothelial shear stress in humans. , 2013, EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology.

[3]  Matthias Graeser,et al.  Towards Picogram Detection of Superparamagnetic Iron-Oxide Particles Using a Gradiometric Receive Coil , 2017, Scientific Reports.

[4]  Alexander Schlaefer,et al.  Feasibility of respiratory motion-compensated stereoscopic X-ray tracking for bronchoscopy , 2014, International Journal of Computer Assisted Radiology and Surgery.

[5]  Tobias Knopp,et al.  Edge Preserving and Noise Reducing Reconstruction for Magnetic Particle Imaging , 2017, IEEE Transactions on Medical Imaging.

[6]  Yongtian Wang,et al.  External force back-projective composition and globally deformable optimization for 3-D coronary artery reconstruction , 2014, Physics in medicine and biology.

[7]  B Gleich,et al.  Weighted iterative reconstruction for magnetic particle imaging , 2010, Physics in medicine and biology.

[8]  Thorsten M Buzug,et al.  Toward cardiovascular interventions guided by magnetic particle imaging: First instrument characterization , 2013, Magnetic resonance in medicine.

[9]  Shengxian Tu,et al.  Development of 3D IVOCT Imaging and Co-Registration of IVOCT and Angiography in the Catheterization Laboratory , 2014, Current Cardiovascular Imaging Reports.

[10]  Richard Solomon,et al.  Contrast-induced acute kidney injury. , 2010, Circulation.

[11]  Pedro A. Lemos,et al.  A robust fully automatic lumen segmentation method for in vivo intracoronary optical coherence tomography , 2016 .

[12]  Wolfgang Draxinger,et al.  Ultra low noise Fourier domain mode locked laser for high quality megahertz optical coherence tomography , 2018, Biomedical optics express.

[13]  T Knopp,et al.  Online reconstruction of 3D magnetic particle imaging data , 2016, Physics in medicine and biology.

[14]  R. Pazdur,et al.  FDA report: Ferumoxytol for intravenous iron therapy in adult patients with chronic kidney disease , 2010, American journal of hematology.

[15]  Tobias Knopp,et al.  Magnetic particle imaging: from proof of principle to preclinical applications , 2017, Physics in medicine and biology.

[16]  Jörn Borgert,et al.  Multi-color magnetic particle imaging for cardiovascular interventions , 2016, Physics in medicine and biology.

[17]  Caroline C. O'Brien,et al.  Vessel centerline reconstruction from non-isocentric and non-orthogonal paired monoplane angiographic images , 2017, The International Journal of Cardiovascular Imaging.

[18]  Olaf Dössel,et al.  Evaluation of Induced Current Densities and SAR in the Human Body by Strong Magnetic Fields around 100 kHz , 2009 .

[19]  W. O’Neill,et al.  Acute renal failure after coronary intervention: incidence, risk factors, and relationship to mortality. , 1997, The American journal of medicine.

[20]  Nils Gessert,et al.  Force estimation from OCT volumes using 3D CNNs , 2018, International Journal of Computer Assisted Radiology and Surgery.

[21]  Wolfgang Drexler,et al.  Optical coherence tomography: Technology and applications , 2013, 2013 Conference on Lasers & Electro-Optics Europe & International Quantum Electronics Conference CLEO EUROPE/IQEC.

[22]  Olaf Dössel,et al.  Optimizing Coil Currents for reduced SAR in Magnetic Particle Imaging , 2009 .

[23]  Tobias Knopp,et al.  In vitro and in vivo comparison of a tailored magnetic particle imaging blood pool tracer with Resovist , 2017, Physics in medicine and biology.

[24]  Jochen Franke,et al.  Magnetic Particle Imaging: A Resovist based Marking Technology for Guide Wires and Catheters for Vascular Interventions. , 2016, IEEE transactions on medical imaging.

[25]  T Knopp,et al.  Recent progress in magnetic particle imaging: from hardware to preclinical applications , 2017, Physics in medicine and biology.

[26]  R. Katzberg,et al.  Contrast-induced nephrotoxicity: clinical landscape. , 2006, Kidney international. Supplement.

[27]  Bernhard Gleich,et al.  MPI Safety in the View of MRI Safety Standards , 2015, IEEE Transactions on Magnetics.

[28]  Alexander Schlaefer,et al.  Submillimeter-Accurate Marker Localization within Low Gradient Magnetic Particle Imaging Tomograms , 2017 .

[29]  G. Ripandelli,et al.  Optical coherence tomography. , 1998, Seminars in ophthalmology.

[30]  Bernhard Gleich,et al.  Magnetic Particle imaging : Visualization of Instruments for Cardiovascular Intervention 1 , 2012 .

[31]  Gijs van Soest,et al.  Heartbeat OCT: in vivo intravascular megahertz-optical coherence tomography. , 2015, Biomedical optics express.

[32]  Paula M Jacobs,et al.  Ultrasmall superparamagnetic iron oxides (USPIOs): a future alternative magnetic resonance (MR) contrast agent for patients at risk for nephrogenic systemic fibrosis (NSF)? , 2009, Kidney international.

[33]  杨健 External force back-projective composition and globally deformable optimization for 3-D coronary artery reconstruction , 2014 .

[34]  Akiko Maehara,et al.  Consensus standards for acquisition, measurement, and reporting of intravascular optical coherence tomography studies: a report from the International Working Group for Intravascular Optical Coherence Tomography Standardization and Validation. , 2012, Journal of the American College of Cardiology.

[35]  Thorsten M. Buzug,et al.  Artifact free reconstruction with the system matrix approach by overscanning the field-free-point trajectory in magnetic particle imaging , 2016, Physics in medicine and biology.

[36]  Dimitrios I. Fotiadis,et al.  3D reconstruction of coronary arteries using Frequency Domain Optical Coherence Tomography images and biplane angiography , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[37]  Patrick W. Goodwill,et al.  Magnetostimulation Limits in Magnetic Particle Imaging , 2013, IEEE Transactions on Medical Imaging.

[38]  G. Ippolito,et al.  Socioeconomic status and biomedical risk factors in migrants and native tuberculosis patients in Italy , 2017, PloS one.

[39]  Tobias Knopp,et al.  Magnetic Particle / Magnetic Resonance Imaging: In-Vitro MPI-Guided Real Time Catheter Tracking and 4D Angioplasty Using a Road Map and Blood Pool Tracer Approach , 2016, PloS one.